Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

101118496 - TR 330-11Y-1903

Description: Product type description:MR 330-11Y-M20/RMS-(1)(1)withoutIncluded in standard version1366temperature-resistant variant up to +160 °C incl. 10° toothing for swivel levers
Description: Product type description:MR 330-11Y-M20/RMS-(1)(1)withoutIncluded in standard version1366temperature-resistant variant up to +160 °C incl. 10° toothing for swivel levers
Productfeatures
  • can be used as a safety switch
  • temperature resistant version (up to 160°C)
  • Actuator head can be repositioned in steps 4 x 90°
  • Metal enclosure
  • Long life
  • 40 mm x 76 mm x 40 mm ( basic component)
  • Suitable for low actuating speeds
  • 1 Cable entry M 20 x 1.5
  • free of silicon
  • proved in power station applications
Data
Ordering data

Product type description

TR 330-11Y-1903

Article number (order number)

101118496

EAN (European Article Number)

4030661275550

eCl@ss number, version 9.0

27-27-06-01

eCl@ss number, version 11.0

27-27-06-01

eCl@ss number, version 12.0

27-27-06-01

ETIM number, version 7.0

EC000030

ETIM number, version 6.0

EC000030

General data

Standards

EN 60947-5-1

Working principle

mechanical

Enclosure material

Light-alloy diecast, paint finish

Enclosure coating material

painted

Material of the contacts, electrical

Gold-plated silver

Roller material

Brass

Gross weight

205 g

Safety classification - Safety outputs

B

20,000,000 Operations

Mechanical data

Actuating element

Roller plunger

Actuating force, minimum

17.5 N

Actuating speed, minimum

1 mm/min

Mechanical data - Dimensions

Length of sensor

40 mm

Width of sensor

40 mm

Height of sensor

116.5 mm

Width of Castor

4.6 mm

Diameter of Castor

17.2 mm

Ambient conditions

Degree of protection

IP65

Ambient temperature, minimum

-30 °C

Ambient temperature, maximum

+160 °C

Restistance to shock

50 g / 6 ms

Ambient conditions - Insulation values

Rated insulation voltage U

500 V

Rated impulse withstand voltage U

4 kV

Electrical data

Thermal test current

6 A

Note

Note (General)

Actuation from the side of the plunger should be avoided, since this reduces the mechanical life of the position switch.

Operating instructions (supplementary sheet/quick guide)
  • M 330

    Download
EC Declaration of conformity
  • M 330

    Download
DNV-GL Certificate
  • M 330

    Download