Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

101126703 - AZS 2305 24 VDC

Description:
Productfeatures
  • Fail-safe delay timer
  • Time adjustable from 0,1 s to 99 min
  • 3 safety contacts
  • 2 Signalling outputs
Data
Ordering data

Note (Delivery capacity)

Phased-out product

Product type description

AZS 2305 24 VDC

Article number (order number)

101126703

EAN (European Article Number)

4030661058986

eCl@ss number, version 9.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 12.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Available until

31.12.2021

Approvals - Standards

Certificates

cULus

EAC

General data

Standards

BG-GS-ET-20

EN ISO 13849-1

IEC/EN 60204-1

Enclosure material

Glass-fibre, reinforced thermoplastic

Gross weight

248 g

General data - Features

Wire breakage detection

Yes

Cross-circuit detection

Yes

Automatic reset function

Yes

Reset after disconnection of supply voltage

Yes

Earth connection detection

Yes

Integral system diagnostics, status

Yes

Number of LEDs

1

Number of openers

1

Number of shutters

1

Number of undelayed semi-conductor outputs with signaling function

2

Number of safety contacts

3

Number of signalling outputs

2

Mechanical data

Mounting

Snaps onto standard DIN rail to EN 60715

Mechanical data - Connection technique

Type of connection

Screw terminals M20 x 1.5

rigid or flexible

Cable section, maximum

4 mm²

Note (Cable section)

All indications including the conductor ferrules.

Tightening torque of Clips

0.4 Nm

Mechanical data - Dimensions

Width

55 mm

Height

75 mm

Depth

110 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+55 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+70 °C

Resistance to vibration to EN 60068-2-6

10 ... 55 Hz, Amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation values

Rated impulse withstand voltage U

4 kV

Overvoltage category

III

Degree of pollution to VDE 0110

2

Electrical data

Frequency range

50 Hz

60 Hz

Rated operating voltage

24 VDC ± 15 %

Rated AC voltage for controls at DC minimum

20.4 VDC

Rated control voltage at DC, maximum

27.6 VDC

Electrical power consumption

5 W

Contact resistance, maximum

0.1 Ω

Note (Contact resistance)

in new state

Drop-out delay in case of power failure, typically

80 ms

Drop-out delay in case of emergency, typically

20 ms

Pull-in delay at automatic start, maximum, typically

100 ms

Pull-in delay at RESET, typically

20 ms

Electrical data - Safe relay outputs

Voltage, Utilisation category AC-15

250 VAC

Current, Utilisation category AC-15

2 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

2 A

Switching capacity, minimum

10 VDC

Switching capacity, minimum

10 mA

Switching capacity, maximum

250 VAC

Switching capacity, maximum

8 A

Electrical data - Digital inputs

Input signal, HIGH Signal "1"

10 … 30 VDC

Input signal, LOW Signal "0"

0 … 2 VDC

Conduction resistance, maximum

40 Ω

Electrical data - Digital Output

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.1 A

Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum

24 VDC

Switching capacity, maximum

2 A

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMC-Directive

Integral system diagnosis (ISD)

Note (ISD -Faults)

The following faults are registered by the safety monitoring modules and indicated by ISD.

Faults

Failure of the safety relay to pull-in or drop-out

Fault on the input circuits or the relay control circuits of the safety monitoring module

Difference in time setting between channel I and channel II

Cross conclusions to the input lines

Interruption of the input connections

Other data

Note (applications)

Fail-safe delay timer

Note

Note (General)

Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Operating instructions and Declaration of conformity
  • AZS 2305

    Download
BG-test certificate
  • AZS 2305

    Download
UL Certificate
  • (385.6 kB, 08/01/2019)

    Download
Force-travel diagram
  • AZS 2305

    Download