Productfeatures
  • To monitor 1 ... 4 safety edge(s)
  • 1 safety contact, STOP 0
  • 1 Signalling output
Data
Ordering data

Product type description

SE-304 C AUSWERTEGERAET

Article number (order number)

101165883

EAN (European Article Number)

4030661293622

eCl@ss number, version 9.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 12.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Approvals - Standards

Certificates

TÜV

EAC

General data

Standards

EN ISO 13849-1

EN ISO 13850

Climatic stress

EN ISO 13856-2

Enclosure material

Glass-fibre, thermoplastic

Gross weight

175 g

Reaction time, maximum

17 ms

General data - Features

Stop-Category

0

Electronic Fuse

Yes

Wire breakage detection

Yes

Cross-circuit detection

Yes

Start input

Yes

Feedback circuit

Yes

Automatic reset function

Yes

Reset edge detection

Yes

Reset after disconnection of supply voltage

Yes

Earth connection detection

Yes

Integral system diagnostics, status

Yes

Number of LEDs

5

Number of undelayed semi-conductor outputs with signaling function

1

Number of safety contacts

1

Number of signalling outputs

1

Mechanical data

Mechanical life, minimum

10,000,000 Operations

Mounting

Snaps onto standard DIN rail to EN 60715

Mechanical data - Connection technique

Type of connection

Screw terminals M20 x 1.5

Length of cable

200 m

Cable section, maximum

2 x 1.5 mm²

Note (Cable section)

All indications including the conductor ferrules.

Mechanical data - Dimensions

Width

22.5 mm

Height

100 mm

Depth

121 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature, minimum

+5 °C

Ambient temperature, maximum

+55 °C

Resistance to vibration to EN 60068-2-6

10 … 55 Hz, amplitude 0.15 mm

Ambient conditions - Insulation values

Rated impulse withstand voltage U

4 kV

Overvoltage category

III

Degree of pollution to VDE 0110

2

Electrical data

Frequency range

50 Hz

Rated operating voltage

24 VDC +20% / -10%

24 VAC +10% / -10%

Operating current

500 mA

Rated AC voltage for controls, 50 Hz, minimum

21.6 VAC

Rated control voltage at AC 50 Hz, maximum

28.8 VAC

Rated AC voltage for controls at DC minimum

21.6 VDC

Rated control voltage at DC, maximum

28.8 VDC

Utilisation category AC-15

230 VAC

Utilisation category AC-15

2 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

2 A

Electrical power consumption, maximum

4 W

Pull-in delay at RESET

100 ms ... 2000 ms

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMC-Directive

Status indication

Indicated operating states

Authorised operation

fault indication

Other data

Note (applications)

Safety edges

Note

Note (General)

The overall machine safety depends on the professional mounting and installation of the safety monitoring module and the signal transmitter, as well as on the correct and professional electrical connection of the components.