Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

101173041 - NAS 311 ST1-AS

Description:
Productfeatures
  • Thermoplastic actuators
  • Emergency stop station
  • AS-Interface M12 connector
  • 85 mm x 85 mm x 97,8 mm
  • Integrated AS-Interface
  • Pull to reset
  • Resistant to chemicals
Data
Ordering data

Product type description

NAS 311 ST1-AS

Article number (order number)

101173041

EAN (European Article Number)

4030661448831

eCl@ss number, version 9.0

27-37-12-44

eCl@ss number, version 11.0

27-37-12-44

eCl@ss number, version 12.0

27-37-12-44

ETIM number, version 7.0

EC002034

ETIM number, version 6.0

EC002034

Approvals - Standards

Certificates

TÜV

ASi-SaW

General data

Standards

EN 60947-5-1

EN 62026-2

EN ISO 13849-1

EN ISO 13850

IEC 61508

Enclosure material

Plastic

Gross weight

330 g

Mechanical data - Connection technique

Type of connection

Connector plug M12, 4-pole, (A-coding)

Connector position

Bottom

Mechanical data - Dimensions

Length of sensor

97.8 mm

Width of sensor

85 mm

Height of sensor

85 mm

Ambient conditions

Degree of protection

IP65

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+60 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Relative humidity, minimum

30 %

Relative humidity, maximum

95 %

Note (Relative humidity)

non-condensing

non-icing

Electrical data

Current consumption

50 mA

Electrical data - AS Interface

AS-i Operating voltage, minimum

26.5 VDC

AS-i Operating voltage AS-i maximum

31.6 VDC

Note (AS-i Operating voltage)

Protection against polarity reversal

Electrical data - AS-Interface specification

AS-i Version

V 2.1

AS-i Profile

S-7.B.0.E

AS-i, IO-Code

0x7

AS-i, ID-Code

0xB

AS-i, ID-Code1

0xF

AS-i, ID-Code2

0xE

AS-i Input, Channel 1

Data bits DI 0 / DI 1 = dynamic code transmission

AS-i Input, Channel 2

Data bits DI 2 / DI 3 = dynamic code transmission

AS-i Outputs, DO 0 … DO 3

No Function

AS-i Parameter bits, P0 ... P3

No function

AS-i Input module address

0

Note (AS-i Input module address)

Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Operating instructions and Declaration of conformity
  • NAS311AS

    Download
AS interface safety at work certificate
  • NAS311AS

    Download
SISTEMA-VDMA library
  • (109.5 kB, 11/11/2021)

    Download
  • SISTEMA

    Download