101182592 - SSW301HV-115V
- Brand: Schmersal
- Product Code: 101182592
- Fail-safe standstill monitors
- This fail-safe standstill monitor has the particular advantage that no adjustment for a required-value is needed during comissioning.
- 3 safety contacts, STOP 0
- Control category 4 to ISO 13849-1
Data
Ordering data
Product type description | SSW301HV-115V |
Article number (order number) | 101182592 |
EAN (European Article Number) | 4250116202607 |
eCl@ss number, version 9.0 | 27-37-18-19 |
eCl@ss number, version 11.0 | 27-37-18-19 |
eCl@ss number, version 12.0 | 27-37-18-19 |
ETIM number, version 7.0 | EC001449 |
ETIM number, version 6.0 | EC001449 |
Approvals - Standards
Certificates | cULus CCC EAC |
General data
Standards | EN 60947-5-1 EN ISO 13849-1 IEC 61508 IEC/EN 60204-1 |
Climatic stress | EN 60068-2-78 |
Enclosure material | Glass-fibre, reinforced thermoplastic |
Material of the contacts, electrical | AgSn0 + Au, self-cleaning, positive drive |
Gross weight | 500 g |
General data - Features
Stop-Category | 0 |
Wire breakage detection | Yes |
Cross-circuit detection | Yes |
Feedback circuit | Yes |
Automatic reset function | Yes |
Earth connection detection | Yes |
Integral system diagnostics, status | Yes |
Number of auxiliary contacts | 1 |
Number of LEDs | 5 |
Number of safety contacts | 3 |
Mechanical data
Mechanical life, minimum | 10,000,000 Operations |
Mounting | Snaps onto standard DIN rail to EN 60715 |
Mechanical data - Connection technique
Type of connection | Screw terminals M20 x 1.5 rigid or flexible |
Terminal designations | IEC/EN 60947-1 |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 2.5 mm² |
Tightening torque of Clips | 0.6 Nm |
Mechanical data - Dimensions
Width | 90 mm |
Height | 83 mm |
Depth | 127 mm |
Ambient conditions
Degree of protection of the enclosure | IP40 |
Degree of protection of the mounting space | IP54 |
Degree of protection of clips or terminals | IP20 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +45 °C |
Storage and transport temperature, minimum | -40 °C |
Storage and transport temperature, maximum | +85 °C |
Resistance to vibration to EN 60068-2-6 | 10 ... 55 Hz, Amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage U | 4 kV |
Degree of pollution to IEC/EN 60664-1 | 2 |
Electrical data
Rated operating voltage | 115 VAC -15% / +10% |
Rated AC voltage for controls, 50 Hz, minimum | 97.8 VAC |
Rated control voltage at AC 50 Hz, maximum | 126.5 VAC |
Rated AC voltage for controls, 60 Hz, minimum | 97.8 VAC |
Rated control voltage at AC 60 Hz, maximum | 126.5 VAC |
Electrical power consumption, maximum | 4 W |
Contact resistance, maximum | 0.1 Ω |
Note (Contact resistance) | in new state |
Drop-out delay in case of "emergency stop", maximum | 15 ms |
Pull-in delay at automatic start (after detecting standstill), approx. | 7,000 ms |
Electrical data - Safe relay outputs
Voltage, Utilisation category AC-15 | 230 VAC |
Current, Utilisation category AC-15 | 6 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 6 A |
Switching capacity, minimum | 10 VDC |
Switching capacity, minimum | 10 mA |
Switching capacity, maximum | 250 VAC |
Switching capacity, maximum | 8 A |
Electrical data - Digital inputs
Conduction resistance, maximum | 40 Ω |
Electrical data - Relay outputs (auxiliary contacts)
Switching capacity, maximum | 24 VDC |
Switching capacity, maximum | 2 A |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating | EMC-Directive |
Status indication
Indicated operating states | OUT, green: release switching condition UB: Supply voltage on ERR: Error functional defect |
Other data
Note (applications) | safe standstill monitoring |