101199467 - ZSD5/O.LTG.
- Brand: Schmersal
- Product Code: 101199467
- 3 levels OFF-ON-OFF
- Thermoplastic enclosure
- 1 Cable entry M 20 x 1.5
- Good resistance to oil and petroleum spirit
- Particularly fit for robot applications in accordance with the ANSI Robotics Standard
- The redundant contact configuration enables signal processing using conventional safety relay modules
- Contacts do not close upon reset (level 3 -> level 1)
Data
Ordering data
Product type description | ZSD5/O.LTG. |
Article number (order number) | 101199467 |
EAN (European Article Number) | 4030661521435 |
eCl@ss number, version 9.0 | 27-37-12-38 |
eCl@ss number, version 11.0 | 27-37-12-38 |
eCl@ss number, version 12.0 | 27-37-12-38 |
ETIM number, version 7.0 | EC002571 |
ETIM number, version 6.0 | EC002571 |
Approvals - Standards
Certificates | cULus |
General data
Standards | ANSI/RIA R15.06 CSA C22.2 Nr.14 EN 775 IEC 60204-1 IEC 60947-5-1 ISO 10218 ISO 11161 ISO 12100 JIS C8201-5-1 UL508 1 |
Enclosure material | Plastic, thermoplastic, self-extinguishing |
Material of the contacts, electrical | Silver |
Gross weight | 190 g |
General data - Features
Number of openers | 1 |
Number of shutters | 2 |
Mechanical data
Note (Mechanical life) | NO: Stage 1 - 2 - 1: 1,000,000 operations Stage 1 - 2 - 3 - 1: 100,000 operations |
Mechanical data - Connection technique
Type of connection | Screw terminals M20 x 1.5 |
Cable section, minimum | 0.14 mm² |
Cable section, maximum | 1.5 mm² |
Ambient conditions
Degree of protection | IP65 |
Ambient temperature, minimum | -10 °C |
Ambient temperature, maximum | +60 °C |
Ambient conditions - Insulation values
Rated impulse withstand voltage U | 2.5 kV |
Electrical data
Rated operating voltage | 250 VAC 250 VDC |
Operating current | 3,000 mA |
Switching element | NO contact, NC contact |
Switching principle | Slow action |
Switching frequency | 1,200 /h |
Accessory
Recommended safety switchgear | SRB, 2-channel with cross-wire detection |
Note
Note (General) | Customer-specific versions, with connecting cable, are available upon request. The monitoring module must offer the possibility of cross-wire monitoring. Only a double shielded cable is authorised as supply line. 1) If the device is to be used in a damp room, a suitable connection cable must be used. 1) This device has been tested for impact and fire resistance according to UL508. |