Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

101209550 - MZM 100 ST-AS AP

Description: Product type description:MZM 100 (1) ST-AS (2)(3)AP(1)withoutGuard locking monitored >NB, MBN, BNActuator monitored(2)withoutwithout latching (guard locking monitored only)REelectrically adjustable latching force 30 N … 100 N(3)withoutwithout Permanent magnetMPermanent magnet 30 N
Description: Product type description:MZM 100 (1) ST-AS (2)(3)AP(1)withoutGuard locking monitored >NB, MBN, BNActuator monitored(2)withoutwithout latching (guard locking monitored only)REelectrically adjustable latching force 30 N … 100 N(3)withoutwithout Permanent magnetMPermanent magnet 30 N
Productfeatures
  • Power to lock
  • Guard locking monitored
  • Solenoid interlock
  • Thermoplastic enclosure
  • Integrated AS-Interface
  • 40 mm x 179 mm x 40 mm
  • Solenoid interlocks (for the protection of man) with innovating and unique operating principle
  • Electronic contact-free, coded system
  • 3 LEDs to show operating conditions
  • Automatic latching
  • Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
  • Intelligent diagnosis
Data
Ordering data

Product type description

MZM 100 ST-AS AP

Article number (order number)

101209550

EAN (European Article Number)

4030661383194

eCl@ss number, version 9.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 12.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Approvals - Standards

Certificates

TÜV

cULus

ASi-SaW

EAC

General data

Standards

EN 60947-5-3

EN 62026-2

EN ISO 13849-1

EN ISO 14119

IEC 61508

Coding

Universal coding

Coding level according to ISO 14119

Low

Working principle

inductive

Enclosure material

Glass-fibre, reinforced thermoplastic

Gross weight

600 g

Time to readiness, maximum

4,000 ms

Reaction time, maximum

150 ms

Duration of risk, maximum

150 ms

General data - Features

Power to lock

Yes

Solenoid interlock monitored

Yes

Safety functions

Yes

Integral system diagnostics, status

Yes

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Note (Mechanical life)

Actuating speed < 0.5 m/s

Operations for door weights ≤ 5 kg

Holding force, typically

750 N

Holding force, guaranteed

500 N

Mechanical data - Connection technique

Type of connection

Connector plug M12, 4-pole, (A-coding)

Mechanical data - Dimensions

Length of sensor

40 mm

Width of sensor

40 mm

Height of sensor

179 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+55 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Relative humidity, minimum

30 %

Relative humidity, maximum

95 %

Note (Relative humidity)

non-condensing

non-icing

Resistance to vibration to EN 60068-2-6

10 … 150 Hz, amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Protection class

III

Ambient conditions - Insulation values

Rated insulation voltage U

32 VDC

Rated impulse withstand voltage U

0.8 kV

Overvoltage category

III

Degree of pollution to IEC/EN 60664-1

3

Electrical data - AS Interface

AS-i Operating voltage, minimum

26.5 VDC

AS-i Operating voltage AS-i maximum

31.6 VDC

Note (AS-i Operating voltage)

Protection against polarity reversal

AS-i Current consumption, maximum

100 mA

Electrical data - AS-Interface specification

AS-i Specification

Safety-Slave

AS-i Version

V 2.1

AS-i Profile

S-7.B.F.E

AS-i, IO-Code

0x7

AS-i, ID-Code

0xB

AS-i, ID-Code1

0xF

AS-i, ID-Code2

0xE

AS-i Input, Channel 1

Data bits DI 0 / DI 1 = dynamic code transmission

AS-i Input, Channel 2

Data bits DI 2 / DI 3 = dynamic code transmission

AS-i Outputs, DO 0

Solenoid control

AS-i Outputs, DO 1

No Function

AS-i Outputs, DO 2

No Function

AS-i Outputs, DO 3

No Function

AS-i Parameter bits, P0

Actuator in

AS-i Parameter bits, P1

Solenoid interlock locked

AS-i Parameter bits, P2

Auxiliary voltage in

AS-i Parameter bits, P3

Device error (fault detected)

Note (AS-i Parameter bits)

Set the parameter outputs to "1111" (0xF)

FID: periphery error

AS-i Input module address

0

Note (AS-i Input module address)

Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Electrical data - Auxiliary voltage

Rated operating voltage

24 VDC -15% / +10% (stabilised PELV)

Current consumption

600 mA

Status indication

Note (LED switching conditions display)

(1) LED green-red (AS-i Duo LED): Supply voltage / Communication error / Slave address = 0

(2) LED yellow: Device condition

(3) LED red: Internal device error

Pin assignment

PIN 1

AS-i +

PIN 2

Aux - (P)

PIN 3

AS-Interface -

PIN 4

Aux + (P)

Scope of delivery

Scope of delivery

Actuators must be ordered separately.

Accessory

Recommendation (actuator)

MZM 100-B1.1

Operating instructions and Declaration of conformity
  • MZM 100 AS

    Download
UL Certificate
  • (413.4 kB, 08/01/2019)

    Download
SISTEMA-VDMA library
  • (109.5 kB, 11/11/2021)

    Download
  • TraceParts

    Download
  • SISTEMA

    Download