Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

101212892 - EX-ZQ 900-22-3D

Description: Product type description:EX-ZQ 900 -(1)-3D(1)111 NO contacts/1 NC contact131 NO contacts/3 NC contact222 NO contacts/2 NC contact022 NC contact044 NC contact
Description: Product type description:EX-ZQ 900 -(1)-3D(1)111 NO contacts/1 NC contact131 NO contacts/3 NC contact222 NO contacts/2 NC contact022 NC contact044 NC contact
Productfeatures
  • 3 cable entries M 20 x 1.5
  • Ex-Zone 22
  • Metal enclosure
  • Release push button
  • Position indicator
  • Robust design
  • Large wiring compartment
  • Twisting of towing eye not possible
  • External watertight collar
  • wire pull and breakage detection
  • one-side operation / wire up to 75 m long
Data
Ordering data

Product type description

EX-ZQ 900-22-3D

Article number (order number)

101212892

EAN (European Article Number)

4030661402130

eCl@ss number, version 9.0

27-37-12-01

eCl@ss number, version 11.0

27-37-12-01

eCl@ss number, version 12.0

27-37-12-01

ETIM number, version 7.0

EC002026

ETIM number, version 6.0

EC002026

Explosion protection

Explosion protection: regulations

EN 60079-31

IEC 60079-0

Explosion protection zones

22

Explosion protection category

3D

Explosion protection designation

II 3D Ex tc IIIC T100°C Dc

General data

Standards

EN ISO 13850

IEC/EN 60947-5-1

IEC/EN 60947-5-5

Enclosure material

Zinc die-cast

Enclosure coating material

painted

Material of the contacts, electrical

Silver

Material of the cover

Steel

Length of the wire, maximum

75 m

Gross weight

1,470 g

General data - Features

Number of auxiliary contacts

2

Number of safety contacts

2

Safety classification - Safety outputs

B

100,000 Operations

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Actuating force, maximum

200 N

Actuating travel

400 mm

Mechanical data - Connection technique

Type of connection

Screw terminals M20 x 1.5

Cable cross-section of the cable glands, minimum

7 mm

Cable cross-section of the cable glands, maximum

12 mm

Cable section, minimum

0.75 mm²

Cable section, maximum

2.5 mm²

Note (Cable section)

All indications including the conductor ferrules.

Mechanical data - Dimensions

Length of sensor

57 mm

Width of sensor

71.5 mm

Height of the Sensor, minimum

221 mm

Height of the Sensor, maximum

237 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature, minimum

-20 °C

Ambient temperature, maximum

+55 °C

Relative humidity, minimum

30 %

Relative humidity, maximum

95 %

Ambient conditions - Insulation values

Rated insulation voltage U

500 V

Rated impulse withstand voltage U

6 kV

Electrical data

Thermal test current

4 A

Utilisation category AC-15

230 VAC

Utilisation category AC-15

4 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

1 A

Switching element

NO contact, NC contact

Switching principle

Snap switch element

Scope of delivery

Scope of delivery

Including Ex-certified screwed cable gland and screw plug

Operating instructions and Declaration of conformity
  • EX-ZQ 900

    Download
IECEx certification
  • (145.9 kB, 02/01/2021)

    Download
TÜV certification
  • (166.4 kB, 02/01/2021)

    Download