103003725 - AZM400Z-ST2-I2-2P2P-E
- Brand: Schmersal
- Product Code: 103003725
- Repeated individual coding with RFID technology
- Coding level "High" according to ISO 14119
- 2 Connector M12, 8- and 5-poles
- Guard locking monitored
- 2 Diagnostic outputs
- manual release
- Electric manual release with auxiliary voltage
- Bistable, motor-driven system
- Clamping force 10.000
- Release possible against lateral forces up to 300 N
- PL e / cat. 4 / SIL 3 for interlocking and guard locking function
- Two-channel input signal of the guard locking function
- Operation on P/P- and P/N-switching outputs
- High tolerance to door misalignment
Data
Ordering data
Product type description | AZM400Z-ST2-I2-2P2P-E |
Article number (order number) | 103003725 |
EAN (European Article Number) | 4030661472676 |
eCl@ss number, version 9.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 12.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
Approvals - Standards
Certificates | TÜV cULus EAC FCC IC |
General data
Standards | EN ISO 13849-1 EN ISO 14119 IEC 60947-5-1 IEC 61508 |
Coding | Individual coding, multiple teaching |
Coding level according to ISO 14119 | High |
Working principle | Magnetic field RFID |
Enclosure material | Light alloy die-casting |
Gross weight | 692 g |
Time to readiness, maximum | 1,500 ms |
Reaction time, maximum | 100 ms |
General data - Features
Solenoid interlock monitored | Yes |
Electronic manual release | Yes |
Manual release | Yes |
Short circuit detection | Yes |
Cross-circuit detection | Yes |
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Number of diagnostic signals | 2 |
Number of safety contacts | 2 |
Safety classification - Interlocking function
Performance Level, up to | e |
Category | 4 |
PFH value | 1.00 x 10⁻⁹ /h |
PFD value | 9.00 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Safety classification - Guard locking function
Performance Level, up to | e |
Category | 4 |
PFH value | 1.80 x 10⁻⁹ /h |
PFD value | 1.60 x 10⁻⁴ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Mechanical data
Interlocking principle | bistable |
Mechanical life, minimum | 1,000,000 Operations |
Note (Mechanical life) | Which have a lateral force Ftrans = 100 N: 100.000 operations |
Minimum distance devices | 30 mm |
Holding force in accordance with EN ISO 14119 F | 10,000 N |
Holding force, maximum F | 13,000 N |
Lateral force at bolt return, maximal (against locked door) | 300 N |
Note (Lateral force at bolt return) | Does not apply to emergency exit, Bowden cable and manual release |
Tightening torque of the screw | 8 Nm |
Mechanical data - Connection technique
Type of connection | 2 connector M12, 8 and 5 pin |
Mechanical data - Dimensions
Length of sensor | 46.7 mm |
Width of sensor | 77.8 mm |
Height of sensor | 166.7 mm |
Ambient conditions
Degree of protection | IP67 IP66 |
Ambient temperature, minimum | -20 °C |
Ambient temperature, maximum | +55 °C |
Storage and transport temperature, minimum | -40 °C |
Storage and transport temperature, maximum | +85 °C |
Resistance to vibration to EN 60068-2-6 | 10 … 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | III |
Ambient conditions - Insulation values
Rated insulation voltage U | 32 VDC |
Rated impulse withstand voltage U | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data
Current consumption | 100 mA |
Current consumption, maximum | 600 mA |
Current consumption at 24V, minimum | 10 mA |
Current consumption at 24V, maximum | 15 mA |
No-load supply current, maximum I | 100 mA |
Rated operating voltage | 24 VDC |
Rated operating voltage | 24 VDC |
Operating current | 50 mA |
Required rated short-circuit current to EN 60947-5-1 | 100 A |
Switching frequency, approx. | 0.3 Hz |
Open / close cycle (motor), minimum | 3 |
Minimal average cycle time (with continuous operation) | 20 s |
Electrical data - Control inputs
Switching thresholds of the control inputs | −3 V … 5 V (Low) 15 V … 30 V (High) |
Allowable discrepancy time (input), maximum | 10 s |
Classification ZVEI CB24I, Sink | C0 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Electrical data - Safety digital inputs
Classification ZVEI CB24I, Sink | C1 |
Electrical data - Safety digital outputs
Rated operating current (safety outputs) | 250 mA |
Voltage drop U | 2 V |
Leakage current I | 1.5 mA |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.25 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.25 A |
Classification ZVEI CB24I, Source | C2 |
Classification ZVEI CB24I, Sink | C1 C2 |
Electrical data - Diagnostic outputs
Design of switching elements | short-circuit proof, p-type |
Voltage drop U | 2 V |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.05 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.05 A |
Note | The diagnostic output are not safety relevant outputs! |
Status indication
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
Pin assignment
Connection | Connector 1 |
PIN 1 | OUT2 Diagnostic output 2 |
PIN 2 | E1 Control input 1 |
PIN 3 | n.c. |
PIN 4 | Y1 Safety output 1 |
PIN 5 | OUT1 Diagnostic output 1 |
PIN 6 | E3 Control input 3 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | E2 Control input 2 |
Connection | Connector 2 |
PIN 1 | A1 Supply voltage UB |
PIN 2 | H2 GND |
PIN 3 | A2 GND |
PIN 4 | H1 Auxiliary voltage Uhe |
PIN 5 | FE (functional earth connection) |
Scope of delivery
Scope of delivery | Actuators must be ordered separately. |
Scope of delivery of mounting material | 2 x M6 (10.9) |