Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

103005920 - AZM300Z-I2-ST-AS

Description: Product type description:AZM300(1)(2)-ST-AS-(3)(4)(5)(1)ZGuard locking monitored >BActuator monitored(2)withoutStandard codingI1Individual codingI2Individual coding, multiple teaching(3)withoutPower to unlockAPower to lock(4)withoutMagnet supply from AS-InterfacePMagnet supply 24 VDC (AUX)(5)withoutManual releaseNEmergency releaseTEmergency exitT8Emergency exit, distance 8.5 mm
Description: Product type description:AZM300(1)(2)-ST-AS-(3)(4)(5)(1)ZGuard locking monitored >BActuator monitored(2)withoutStandard codingI1Individual codingI2Individual coding, multiple teaching(3)withoutPower to unlockAPower to lock(4)withoutMagnet supply from AS-InterfacePMagnet supply 24 VDC (AUX)(5)withoutManual releaseNEmergency releaseTEmergency exitT8Emergency exit, distance 8.5 mm
Productfeatures
  • Thermoplastic enclosure
  • Repeated individual coding with RFID technology
  • Coding level "High" according to ISO 14119
  • Suitable for hinged and sliding guards
  • 3 different directions of actuation
  • Guard locking monitored
  • Power to unlock
  • Magnet supply through the AS-Interface
  • Hygienic design
  • Protection class IP 69
  • Solenoid interlock with integrated AS-i Safety Interface
  • Universal repeatedly teachable or individual coding because of the RFID technology
  • I-variants with coding level HIGH to ISO 14119
  • 2 integrated snap-in stages
Data
Ordering data

Product type description

AZM300Z-I2-ST-AS

Article number (order number)

103005920

EAN (European Article Number)

4030661475219

eCl@ss number, version 9.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 12.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Approvals - Standards

Certificates

TÜV

cULus

ASi-SaW

ECOLAB

EAC

FCC

General data

Standards

EN 60947-5-1

EN 62026-2

EN ISO 13849-1

EN ISO 14119

IEC 61508

Coding

Individual coding, multiple teaching

Coding level according to ISO 14119

High

Working principle

RFID

Enclosure material

Glass-fibre, reinforced thermoplastic

Gross weight

605 g

Time to readiness, maximum

5,000 ms

Reaction time, maximum

120 ms

Duration of risk, maximum

200 ms

General data - Features

Power to unlock

Yes

Solenoid interlock monitored

Yes

Latching

Yes

Manual release

Yes

Safety functions

Yes

Integral system diagnostics, status

Yes

Number of actuating directions

3

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Note (Mechanical life)

When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)

Holding force

1,150 N

Latching force, adjustable, position 1

25 N

Latching force, adjustable, position 2

50 N

Mechanical data - Switching distances according EN IEC 60947-5-3

Switching distance

2 mm

Assured switching distance "ON" S

1 mm

Assured switching distance "OFF" S

20 mm

Mechanical data - Connection technique

Type of connection

Connector plug M12, 4-pole, (A-coding)

Mechanical data - Dimensions

Length of sensor

34.4 mm

Width of sensor

87.4 mm

Height of sensor

102.6 mm

Ambient conditions

Degree of protection

IP67

IP69K

IP66

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+60 °C

Storage and transport temperature, minimum

-10 °C

Storage and transport temperature, maximum

+90 °C

Resistance to vibration to EN 60068-2-6

10 … 150 Hz, amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Protection class

II

Ambient conditions - Insulation values

Rated insulation voltage U

32 VDC

Rated impulse withstand voltage U

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data - AS Interface

AS-i Operating voltage, minimum

26.5 VDC

AS-i Operating voltage AS-i maximum

31.6 VDC

Note (AS-i Operating voltage)

Protection against polarity reversal

AS-i Current consumption, maximum

200 mA

Electrical data - AS-Interface specification

AS-i Specification

Safety-Slave

AS-i Version

V 3.0

AS-i Profile

S-7.B.F.E

AS-i Input, Channel 1

Data bits DI 0 / DI 1 = dynamic code transmission

AS-i Input, Channel 2

Data bits DI 2 / DI 3 = dynamic code transmission

AS-i Outputs, DO 0

Solenoid control

AS-i Outputs, DO 1

No Function

AS-i Outputs, DO 2

No Function

AS-i Outputs, DO 3

No Function

AS-i Parameter bits, P0

Safety guard closed and can be locked

AS-i Parameter bits, P1

Solenoid interlock locked

AS-i Parameter bits, P2

Auxiliary voltage in

AS-i Parameter bits, P3

Internal device error (FID)

Note (AS-i Parameter bits)

Set the parameter outputs to "1111" (0xF)

FID: periphery error

AS-i Input module address

0

Note (AS-i Input module address)

Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Status indication

Note (LED switching conditions display)

(1) green/red LED (AS-i duo LED): Supply voltage/communication error/slave address = 0/periphery error detected/device error detected/manipulation protection active

(2) LED yellow: Device condition (Enabling status)

(3) LED red: Internal device error

Pin assignment

PIN 1

AS-Interface +

PIN 2

Aux - (P)

PIN 3

AS-Interface -

PIN 4

Aux + (P)

Scope of delivery

Scope of delivery

Actuators must be ordered separately.

Operating instructions and Declaration of conformity
  • AZM300-AS

    Download
TÜV certification
  • AZM300 , AZ300 , AZM300-AS

    Download
UL Certificate
  • (413.5 kB, 08/01/2019)

    Download
SISTEMA-VDMA library
  • (109.5 kB, 11/11/2021)

    Download
  • SISTEMA

    Download