103008178 - AZM300Z-I2-ST-SD2P-T
- Brand: Schmersal
- Product Code: 103008178
- Repeated individual coding with RFID technology
- Coding level "High" according to ISO 14119
- Connector M12, 8-pole
- Power to unlock
- Guard locking monitored
- serial diagnostic output
- Emergency exit
- Hygienic design
- Protection class IP 69
- Suitable for mounting to profile systems
- Thermoplastic enclosure
- RFID-technology for needs-based protection against tampering
- 3 different directions of actuation
- Compact design
- 3 LEDs to show operating conditions
- Suitable for hinged and sliding guards
- Series-wiring
- Manual release
Data
Ordering data
Product type description | AZM300Z-I2-ST-SD2P-T |
Article number (order number) | 103008178 |
EAN (European Article Number) | 4030661452197 |
eCl@ss number, version 9.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 12.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
Approvals - Standards
Certificates | TÜV cULus ECOLAB EAC FCC IC |
General data
Standards | EN ISO 13849-1 EN ISO 14119 IEC 60947-5-3 IEC 61508 |
Coding | Individual coding, multiple teaching |
Coding level according to ISO 14119 | High |
Working principle | RFID |
Frequency band RFID | 125 kHz |
Transmitter output, maximum | -6 dB/m |
Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Gross weight | 660.1 g |
Time to readiness, maximum | 5,000 ms |
Duration of risk, maximum | 200 ms |
Reaction time, switching off safety outputs via actuator, maximum | 100 ms |
Reaction time, switching off safety outputs via safety inputs, maximum | 1.5 ms |
General data - Features
Power to unlock | Yes |
Solenoid interlock monitored | Yes |
Serial diagnostics | Yes |
Latching | Yes |
Emergency exit | Yes |
Short circuit detection | Yes |
Cross-circuit detection | Yes |
Series-wiring | Yes |
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Number of fail-safe digital outputs | 2 |
Safety classification - Interlocking function
Performance Level, up to | e |
Category | 4 |
PFH value | 5.20 x 10⁻¹⁰ /h |
PFD value | 4.50 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Note (Mechanical life) | When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) |
Angular misalignment between solenoid interlock and actuator, maximum | 2 ° |
Holding force in accordance with EN ISO 14119 F | 1,150 N |
Holding force, maximum F | 1,500 N |
Latching force, adjustable, position 1 | 25 N |
Latching force, adjustable, position 2 | 50 N |
Type of the fixing screws | 2x M6 |
Tightening torque of the fixing screws, minimum | 6 Nm |
Tightening torque of the fixing screws, maximum | 7 Nm |
Mechanical data - Switching distances according EN IEC 60947-5-3
Switching distance | 2 mm |
Assured switching distance "ON" S | 1 mm |
Assured switching distance "OFF" S | 20 mm |
Mechanical data - Connection technique
Type of connection | Connector M12, 8-pole, A-coded |
Length of sensor chain, maximum | 200 m |
Note (length of the sensor chain) | Cable length and cross-section change the voltage drop dependiing on the output current |
Note (series-wiring) | Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD |
Mechanical data - Dimensions
Length of sensor | 146 mm |
Width of sensor | 87.5 mm |
Height of sensor | 55 mm |
Ambient conditions
Degree of protection | IP67 IP69 IP66 |
Ambient temperature, minimum | +0 °C |
Ambient temperature, maximum | +60 °C |
Storage and transport temperature, minimum | -10 °C |
Storage and transport temperature, maximum | +90 °C |
Relative humidity, maximum | 93 % |
Note (Relative humidity) | non-condensing non-icing |
Resistance to vibration to EN 60068-2-6 | 10 … 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | III |
Permissible installation altitude above sea level, maximum | 2,000 m |
Ambient conditions - Insulation values
Rated insulation voltage U | 32 VDC |
Rated impulse withstand voltage U | 0.8 kV |
Overvoltage category | III |
Degree of pollution to IEC/EN 60664-1 | 3 |
Electrical data
Operating voltage, minimum | 20.4 VDC |
Operating voltage, maximum | 26.4 VDC |
Note (Power supply, general) | stabilised PELV power supply |
No-load supply current, maximum I | 100 mA |
Current consumption with magnet ON, average | 200 mA |
Current consumption with magnet ON, peak | 350 mA / 200 ms |
Required rated short-circuit current to EN 60947-5-1 | 100 A |
External wire and device fuse rating | 2 A gG |
Switching frequency, maximum | 0.5 Hz |
Electrical data - Magnet control
Designation, Magnet control | IN |
Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) |
Magnet switch-on time | 100 % |
Test pulse duration, maximum | 5 ms |
Test pulse interval, minimum | 40 ms |
Classification ZVEI CB24I, Sink | C0 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Electrical data - Safety digital inputs
Designation, Safety inputs | X1 und X2 |
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24V | 5 mA |
Test pulse duration, maximum | 1 ms |
Test pulse interval, minimum | 100 ms |
Classification ZVEI CB24I, Sink | C1 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Electrical data - Safety digital outputs
Designation, Safety outputs | Y1 and Y2 |
Design of switching elements | short-circuit proof, p-type |
Voltage drop U | 4 V |
Leakage current I | 0.5 mA |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.25 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.25 A |
Test pulse duration, maximum | 0.5 ms |
Test pulse interval, typical | 1000 ms |
Classification ZVEI CB24I, Source | C2 |
Classification ZVEI CB24I, Sink | C1 C2 |
Electrical data - Diagnostic outputs
Designation, Diagnostic outputs | OUT |
Design of switching elements | short-circuit proof, p-type |
Voltage drop U | 4 V |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.05 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.05 A |
Electrical data - Serial diagnostic SD
Operation current | 150 mA |
Wiring capacitance | 50 nF |
Status indication
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
Pin assignment
PIN 1 | A1 Supply voltage UB |
PIN 2 | X1 Safety input 1 |
PIN 3 | A2 GND |
PIN 4 | Y1 Safety output 1 |
PIN 5 | OUT serial diagnostic output |
PIN 6 | X2 Safety input 2 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | IN serial diagnostic input |
Scope of delivery
Scope of delivery | Actuators must be ordered separately. |
Accessory
Recommendation (actuator) | AZ/AZM300-B1 |