- Safety fieldbox for PROFINET/PROFIsafe
- For connection of up to 8 safety switching devices
- Integrated dual-port switch, IRT-capable
- Protection class IP67
Data
Ordering data
Product type description | SFB-PN-IRT-8M12-IOP |
Article number (order number) | 103015478 |
EAN (European Article Number) | 4030661516875 |
eCl@ss number, version 9.0 | 27-24-26-02 |
eCl@ss number, version 11.0 | 27-24-26-02 |
eCl@ss number, version 12.0 | 27-24-26-02 |
ETIM number, version 7.0 | EC001597 |
ETIM number, version 6.0 | EC001597 |
Available until | 08.04.2022 |
Approvals - Standards
Certificates | TÜV cULus PROFIBUS |
General data
Standards | EN 61131-1 EN 61131-2 EN ISO 13849-1 IEC 60947-5-3 IEC 61508 IEC 62061 |
Enclosure material | Thermoplastic, Polyamide PA 6 GF |
Material of the identification label | Plastic, Polyamide PA |
Material of viewing window | Polyamide PACM 12 |
Material of electronic encapsulation | Polyurethane 2K PU |
Gross weight | 655 g |
Time to readiness, maximum | 8,000 ms |
General data - Features
Integral system diagnostics, general | Yes |
Mechanical data
Mounting | Screws |
Type of the fixing screws | 2x M6 |
Tightening torque of the fixing screws, maximum | 3 Nm |
Mechanical data - Connection technique
Type of connection | M12 Connector socket/connector |
Terminal connector, Input/Output | X0 - X7: M12, 8-pole, A-coded |
Terminal Connector, Power I/O | M12 POWER, 4-pole, T-coded |
Terminal Connector, Field bus | PROFINET P1/P2: M12, 4-pole, D-coded |
Tightening torque of electrical connection | 1 Nm |
Tightening torque of electrical connection, maximum | 1.5 Nm |
Mechanical data - Dimensions
Length | 222.8 mm |
Width | 63 mm |
Height | 36.1 mm |
Ambient conditions
Degree of protection | IP65 IP67 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +55 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +70 °C |
Relative humidity, minimum | 10 % |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing |
Resistance to vibration to EN 60068-2-6 | 10 … 150 Hz (0.35 mm / 5 g) 5 … 10 Hz, amplitude 3.5 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | III |
Permissible installation altitude above sea level, maximum | 2,000 m |
Ambient conditions - Insulation values
Rated insulation voltage U | 32 VDC |
Rated impulse withstand voltage U | 0.8 kV |
Overvoltage category | III |
Degree of pollution to IEC/EN 60664-1 | 3 |
Electrical data
Operating voltage | 24 V |
Current consumption | 200 mA |
Rated operating voltage | 24 VDC - 15 % / + 10 % (stabilised PELV) |
Operating current | 10,000 mA |
Device Watchdog Time | 10 ms |
Device Acknowledgement Time, maximum | 25 ms |
Worst Case Delay Time, maximum | 20 ms |
Worst Case Delay Time, maximum | 50 ms |
Electrical data - Communication protocols
Field bus | PROFINET / PROFIsafe |
PROFINET, Specification | V2.3, Conformance Class C |
PROFIsafe, Specification | V2.4 |
PROFINET, Options | Media Redundancy Protocol (MRP) Fast Start Up |
PROFINET, Network load class | 3 |
Transfer rate | 100 Mbit/s Full Duplex |
Adressing | Discovery and Configuration Protocol (DCP) |
Integrated switch | Dual Port, 100 Mbit/s, IRT fähig |
PROFINET, Services | I&M0 ... I&M3, SNMP, LLDP |
Service interface | WEB-Interface HTTP |
Electrical data - Safety digital inputs
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Classification ZVEI CB24I, Sink | C1 |
Classification ZVEI CB24I, Source | C1 C2 |
Electrical data - Digital Output
Classification ZVEI CB24I, Sink | C1 |
Classification ZVEI CB24I, Source | C1 |
Electrical data - Test pulse output
Classification ZVEI CB24I, Sink | C1 |
Classification ZVEI CB24I, Source | C1 |
LED status display - LED 01
LED status | Error LED device port |
LED position | E: 0 ... 7 |
LED colour | green/red |
LED status display - LED 02
LED status | Input LED device port |
LED position | I: 0 ... 7 |
LED colour | Yellow |
LED status display - LED 03
LED status | LED Link Ethernet port |
LED position | L: P1 + P2 |
LED colour | Green |
LED status display - LED 04
LED status | LED Activity Ethernet port |
LED position | A: P1 + P2 |
LED colour | Green |