2759-290/211-1000 - e!RUNTIME; IEC-60870-Slave; Single License; Online Activation

  • Brand: Wago
  • Product Code: 2759-290/211-1000
Description: Function: The parameters for communication per the IEC 60870 Protocol can be set with a configurator integrated into the e!COCKPIT Software. The configurator sets up IEC 60870 objects while configuring data exchange to the PLC application or I/O modules. Import and export functions in CSV format allow configured data to be transmitted to other engineering tools. With this license, the IEC 60870-5-101 and -104 Protocols can be activated on the slave, and the protocol -103 activated on the master only. This permits the creation of gateways that convert one protocol into another, e.g., allowing protection devices to be read out via IEC 60870-5-103 and data to be transmitted to the network control system via IEC 60870-5-104. The time on the telecontrol substation (slave) can be directly synchronized via either the IEC 60870 Protocol with object 103 or via (S)NTP. IEC 60870-5-101/-104 Information Objects can be used to monitor the direction of single, double and step messages – bit patterns, counter values, as well as normalized, scaled and floating-point measurement values can also be used. All information objects can be transmitted with or without a time stamp. This also applies to information objects in the control direction. An IEC 60870-5-104 Slave can simultaneously maintain up to four connections to the control system (master). Your Benefits: Use the PFC200 Controller as a telecontrol substation (slave) on an IEC 60870-5-101/-104 Control System (master). Process data from one or more IEC 60870-5-103 Protection Devices (slaves) with the PFC200 Controller (master). Create a gateway application to transfer data from IEC 60870-5-103 Protection Devices to an IEC 60870-5-101/-104 Control System. Use: Enter the license into e!COCKPIT, assign it to a device and load both the license and project into the controller. No other installation steps are required. Technical Data: See Section “Functionality of the WAGO Protocol Library according to IEC 60870-5-101, and -104” in Product Manual “Planning DNP3/IEC-60870 with the Telecontrol Configurator and e!COCKPIT.“
Description: Function: The parameters for communication per the IEC 60870 Protocol can be set with a configurator integrated into the e!COCKPIT Software. The configurator sets up IEC 60870 objects while configuring data exchange to the PLC application or I/O modules. Import and export functions in CSV format allow configured data to be transmitted to other engineering tools. With this license, the IEC 60870-5-101 and -104 Protocols can be activated on the slave, and the protocol -103 activated on the master only. This permits the creation of gateways that convert one protocol into another, e.g., allowing protection devices to be read out via IEC 60870-5-103 and data to be transmitted to the network control system via IEC 60870-5-104. The time on the telecontrol substation (slave) can be directly synchronized via either the IEC 60870 Protocol with object 103 or via (S)NTP. IEC 60870-5-101/-104 Information Objects can be used to monitor the direction of single, double and step messages – bit patterns, counter values, as well as normalized, scaled and floating-point measurement values can also be used. All information objects can be transmitted with or without a time stamp. This also applies to information objects in the control direction. An IEC 60870-5-104 Slave can simultaneously maintain up to four connections to the control system (master). Your Benefits: Use the PFC200 Controller as a telecontrol substation (slave) on an IEC 60870-5-101/-104 Control System (master). Process data from one or more IEC 60870-5-103 Protection Devices (slaves) with the PFC200 Controller (master). Create a gateway application to transfer data from IEC 60870-5-103 Protection Devices to an IEC 60870-5-101/-104 Control System. Use: Enter the license into e!COCKPIT, assign it to a device and load both the license and project into the controller. No other installation steps are required. Technical Data: See Section “Functionality of the WAGO Protocol Library according to IEC 60870-5-101, and -104” in Product Manual “Planning DNP3/IEC-60870 with the Telecontrol Configurator and e!COCKPIT.“
  • Available Quantity: 0

$350.90

System requirements

Other required software

e!COCKPIT version: V1.7

Software data

Supported devices

750-8210: PFC200; G2; 4ETH RS

750-8210/025-000: PFC200; G2; 4ETH RS; T

750-8210/040-000: PFC200; G2; 4ETH RS; XTR

750-8217: PFC200; G2; LTE 2ETH RS

750-8217/025-000: PFC200; G2; LTE 2ETH RS; T

Delivery

Delivery type

License certificate via email (e!COCKPIT already contains the software itself)

License type (note)

The single license allows installation on one controller. One license per controller is required.

License type (note) (2)

A PC with both Internet connection and e!COCKPIT may be required for license activation.

Manual
  • Configure IEC 60870

    Download
System Description
  • Software ‒ General Product Information

    Download