Description: Short description: WAGOs current signal conditioner measures AC/DC currents up to 100 A, while converting the measured current into an analog standard signal at the output. Features: Both digital signal output and relay with changeover contact react to configured measurement range limits (on/off switching delay and threshold value switch function can be configured with up to two threshold values). Clipping capability for analog signal limitation to output end values Adjustable software filter Input/output response simulation via configuration display Safe 3-way isolation with 3 kV test voltage per EN 61010-1
Description: Short description: WAGOs current signal conditioner measures AC/DC currents up to 100 A, while converting the measured current into an analog standard signal at the output. Features: Both digital signal output and relay with changeover contact react to configured measurement range limits (on/off switching delay and threshold value switch function can be configured with up to two threshold values). Clipping capability for analog signal limitation to output end values Adjustable software filter Input/output response simulation via configuration display Safe 3-way isolation with 3 kV test voltage per EN 61010-1
  • Available Quantity: 0

$862.70

Technical data
Configuration

Configuration options

DIP switch

WAGO Interface Configuration Software

WAGO Interface Configuration App

WAGO Configuration Display

DIP switch

WAGO Interface Configuration Software

WAGO Interface Configuration App

WAGO Configuration Display

Input

Input signal type

Current

Input signal (A)

AC 0.5 … 100 A

DC ±100 A

Frequency range

15 … 1000 Hz

Input current (max.)

100 A AC/DC

Response threshold

500 mA (AC); 250 mA (DC)

Resolution (current)

10 mA

10 mA

Output – analog

Output signal type

Current

Voltage

Output signal (V)

± 5 V

0 … 5 V

1 … 5 V

± 10 V

0 … 10 V

2 … 10 V

Output signal (A)

±10 mA

0 … 10 mA

2 … 10 mA

±20 mA

0 … 20 mA

4 … 20 mA

Load impedance (voltage output)

≥ 1 kΩ

Load impedance (current output)

≤ 600 Ω

Output – digital

Switching voltage (DO) max.

Supply voltage (applied): −0.3 V

Continuous current (DO) max.

100 mA (no internal restriction)

Number of switching thresholds (DO)

1 or 2 (adjustable)

Configurable rise/fall delay time (DO)

0 … 60 s (via software)

Output – relay

Dielectric strength (open contact) (AC, 1 min)

1

Number of changeover contacts

1

Contact material (relay)

AgNi + Au

Switching voltage (max.)

AC 250 V

Limiting continuous current (relay; module assembly)

6 A (≤ 60 °C); 3 A (60 … 70 °C)

Dielectric strength (open contact) (AC, 1 min)

1 kVrms

Pull-in time (typ.)

8

Drop-out time (typ.)

4

Bounce time (typ.)

8

Number of switching thresholds (relay)

1 or 2 (adjustable)

Configurable rise/fall delay time (relay)

0 … 60 s (via software)

Signal processing

Measurement method

True RMS measurement; Arithmetic mean value

Limit frequency

3.3 kHz

Software filter (adjustable)

Moving average value (filter level: 30)

Step response (typ.)

60 ms (DC; for software filter 3/default setting); 250 ms (AC)

Measurement error

Transmission error (max.)

≤ 1 % (of the full scale value)

Temperature coefficient

≤ 0.01 %/K

Supply

Power supply type

24 VDC

Nominal supply voltage US

DC 24 V

Supply voltage range

±30 %

Current consumption at nominal supply voltage

≤ 50 mA (+ IDO)

Notes

Note

  • This product is supplied with 24 VDC, which can be commoned using lateral push-in type jumper bars: (6.1) US+ (BR) and (6.2) GND 2 (BR). With this variant, it is necessary to ensure that the maximum permissible total current of 2 A is not exceeded.
  • Additional setting options via WAGO Interface Configuration Software or WAGO Configuration Display

Safety and protection

Rated voltage of the measurement circuit connections per EN 61010-2-030

AC 300 V

Measurement category per EN/UL 61010-2-030

CAT II (input)

Note on insulation parameters

The digital output (DO) is at the potential of the supply.

The conductor carrying the measurement current must have at least basic insulation for the voltage used.

The nominal insulation voltage of the conductor carrying the measurement current must be at least 1390 Vrms AC or 1390 VDC.

The digital output (DO) is at the potential of the supply

Protection type

IP20

Connection data

Connection technology

Push-in CAGE CLAMP®

WAGO connector

picoMAX® 5.0

Solid conductor

0.2 … 2.5 mm² / 24 … 12 AWG

Fine-stranded conductor

0.2 … 2.5 mm² / 24 … 12 AWG

Strip length

9 … 10 mm / 0.35 … 0.39 inches

Feedthrough for measurement conductor

9.5 mm Ø

Physical data

Width

22.5 mm / 0.886 inches

Height

105 mm / 4.134 inches

Depth from upper-edge of DIN-rail

107 mm / 4.213 inches

Mechanical data

Mounting type

DIN-35 rail

Material data

Fire load

1.644

Weight

102.9

Environmental requirements

Ambient temperature (operation)

-40 … +70 °C

Surrounding air temperature (storage)

-40 … +85 °C

Temperature range of connection cable per EN 61010-2-201

≥ (Tambient + 10 K)

Temperature range of connection cable per UL 61010-2-201 (min.)

90

Standards and specifications

Conformity marking

CE

EMC immunity to interference

EN 61000-6-2; EN 61326-2-3; EN 50121-3-2

EMC emission of interference

EN 61000-6-4; EN 61326-2-3; EN 50121-3-2

Standards/specifications

EN 50121-3-2

EN 61010-1

EN 61373

Bid Text
  • 2857-550

    Download
  • 2857-550

    Download
  • 2857-550

    Download
Instruction Leaflet
  • Current Signal Conditioner AC/DC 100 A

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
Software for Interface-Products
  • WAGO Interface Configuration Software G2 FULL

    Download
  • WAGO Interface Configuration Software G2 SMALL

    Download
Firmware
  • 2857-0550, Strommessumformer

    Download
CAD data
  • 2D/3D Models 2857-550

    Download
CAE data
  • EPLAN Data Portal 2857-550

    Download
  • WSCAD Universe 2857-550

    Download
  • ZUKEN Portal 2857-550

    Download
Compliance Search
  • Environmental Product Compliance 2857-550

    Download