750-333 - Fieldbus Coupler PROFIBUS DP; 2nd Generation; 12 MBd

  • Brand: Wago
  • Product Code: 750-333
Description: The 750-333 Fieldbus Coupler maps the peripheral data of all the WAGO I/O Systems I/O modules on PROFIBUS DP. When initializing, the coupler determines the nodes module structure and creates the process image of all inputs and outputs. Modules with a bit width smaller than eight are grouped in one byte for address space optimization. It is furthermore possible to deactivate I/O modules and to modify the image of the node according to the connected signals without having to modify the existing control application. The diagnostic concept is based on ID- and channel-related diagnostics according to EN 50170. This does away with the need for programming modules to evaluate manufacturer-specific diagnostic data.
Description: The 750-333 Fieldbus Coupler maps the peripheral data of all the WAGO I/O Systems I/O modules on PROFIBUS DP. When initializing, the coupler determines the nodes module structure and creates the process image of all inputs and outputs. Modules with a bit width smaller than eight are grouped in one byte for address space optimization. It is furthermore possible to deactivate I/O modules and to modify the image of the node according to the connected signals without having to modify the existing control application. The diagnostic concept is based on ID- and channel-related diagnostics according to EN 50170. This does away with the need for programming modules to evaluate manufacturer-specific diagnostic data.
  • Available Quantity: 0

$633.40

Notes

Note

Note: Configuration files required (GSD)!

Technical data

Communication

PROFIBUS

Number of fieldbus nodes on master (max.)

96

Number of I/O points

6,000

Baud rate

9.6 kBd … 12 MBd

Bus segment length (max.)

1200 m

Transmission medium

Cu cable per EN 50170

Transmission time

typ. 1 ms (10 couplers; each 32 digital I/O and 12 Mbaud) max. 3.3 ms

Number of modules per node (max.)

63

Input and output process image (fieldbus) max.

244 bytes/244 bytes

Supply voltage (system)

24 VDC (-25 … +30 %); via pluggable connector (CAGE CLAMP® connection)

Current consumption (5 V system supply)

200

Total current (system supply)

1,800

Supply voltage (field)

24 VDC (-25 … +30 %); via power jumper contacts

Input current (typ.) at nominal load (24 V)

500

Power supply efficiency (typ.) at nominal load (24 V)

87

Isolation

500 V system/field

Number of outgoing power jumper contacts

3

Current carrying capacity (power jumper contacts)

10

Standard

EN 50170

Connection data

Connection technology: communication/fieldbus

PROFIBUS: 1 x D-Sub 9 socket

Connection technology: field supply

6 x CAGE CLAMP®

Connection technology: system supply

2 x CAGE CLAMP®

Connection technology: device configuration

1 x Male connector; 4-pole

Connection type 1

System/field supply

Solid conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Fine-stranded conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Strip length

8 … 9 mm / 0.31 … 0.35 inches

Physical data

Width

50.5 mm / 1.988 inches

Height

100 mm / 3.937 inches

Depth

71.1 mm / 2.799 inches

Depth from upper-edge of DIN-rail

63.9 mm / 2.516 inches

Mechanical data

Mounting type

DIN-35 rail

Material data

Color

light gray

Housing material

Polycarbonate; polyamide 6.6

Fire load

2.988

Weight

183.1

Conformity marking

CE

Environmental requirements

Ambient temperature (operation)

0 … +55 °C

Surrounding air temperature (storage)

-25 … +85 °C

Protection type

IP20

Pollution degree (5)

2 per IEC 61131-2

Operating altitude

0 … 2000 m / 0 … 6562 ft

Mounting position

horizontal (standing/lying); vertical

Relative humidity (without condensation)

95

Vibration resistance

4g per IEC 60068-2-6

Shock resistance

15g per IEC 60068-2-27

EMC immunity to interference

per EN 61000-6-2, marine applications

EMC emission of interference

per EN 61000-6-4, marine applications

Exposure to pollutants

Per IEC 60068-2-42 and IEC 60068-2-43

Permissible pollutant concentration H2S at a relative humidity < 75%

10

Permissible pollutant concentration SO 2 at a relative humidity < 75%

25

Manual
  • System Manual WAGO I/O System 750 / 753

    Download
  • PROFIBUS DP/ V1 Fieldbus Coupler

    Download
  • System Manual Series 750/753

    Download
Bid Text
  • 750-333

    Download
  • 750-333

    Download
System Description
  • Overview on WAGO-I/O-SYSTEM 750 approvals

    Download
  • Use in Hazardous Environments

    Download
  • 750/753 Series I/O-System ‒ General Product Information

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
Application Note CoDeSys 2.3
  • HART Tool Routing via PROFIBUS with 750-833 and 750-333 (a116140)

    Download
Application note SIEMENS
  • Using iPar-Server option with WAGO PROFIsafe modules (a114802)

    Download
  • PROFIBUS DP & PROFINET IO Diagnose für Siemens CPU 1200 & 1500 (a100211)

    Download
  • PROFIBUS DP & PROFINET IO Diagnose für Siemens CPU 300 & 400 (a100210)

    Download
Firmware
  • 0750-0333, Feldbuskoppler PROFIBUS DP

    Download
CAD data
  • 2D/3D Models 750-333

    Download
CAE data
  • EPLAN Data Portal 750-333

    Download
  • WSCAD Universe 750-333

    Download
  • ZUKEN Portal 750-333

    Download
Device Description File
  • 750-910; GSD files for PROFIBUS / 750, 752, 755, 758 and 767 Series

    Download
Device Driver
  • WAGO USB Service Kabel Treiber / Serie 750 und 857

    Download
Compliance Search
  • Environmental Product Compliance 750-333

    Download