  • Product Code: 750-404/040-003
Description: This counter module can be parameterized. Different operating modes can be set: Up/down counter / 100 kHz Up counter / enable input Peak-time counter Frequency measurement: 0.1 Hz … 100 kHz (default setting) Up/down counter / signal outputs (DO) Two up counters / 16 bits / 5 kHz The modules counter records 24 V binary pulses and transmits the counter status to the fieldbus system. The control byte sets or resets the counter. Digital outputs “DO 1” and “DO 2” can also be set using the control byte. The outputs are short-circuit-protected. Four green LEDs indicate the status of both U/D and CLOCK inputs and digital outputs. Field and system levels are electrically isolated. The device is ideal for operation in extreme environments thanks to: An extended temperature range Greater immunity to impulse voltages and electromagnetic interference Higher vibration and shock resistance
Description: This counter module can be parameterized. Different operating modes can be set: Up/down counter / 100 kHz Up counter / enable input Peak-time counter Frequency measurement: 0.1 Hz … 100 kHz (default setting) Up/down counter / signal outputs (DO) Two up counters / 16 bits / 5 kHz The modules counter records 24 V binary pulses and transmits the counter status to the fieldbus system. The control byte sets or resets the counter. Digital outputs “DO 1” and “DO 2” can also be set using the control byte. The outputs are short-circuit-protected. Four green LEDs indicate the status of both U/D and CLOCK inputs and digital outputs. Field and system levels are electrically isolated. The device is ideal for operation in extreme environments thanks to: An extended temperature range Greater immunity to impulse voltages and electromagnetic interference Higher vibration and shock resistance
  • Available Quantity: 0

$638.00

Technical data

Number of digital outputs

2

Number of counters

1

Signal type

Voltage

Signal type (voltage)

24 VDC

Counter depth

32

Input current (typ.)

7 mA

Output current per channel

0.5

Output current

short-circuit-protected

Switching frequency (max.)

100 kHz

Voltage range for signal (0)

−3 … +5 VDC

Voltage range for signal (1)

15 … 30 VDC

Operating mode

Up/down counter/100 kHz; Up counter/enable input; Peak-time counter; Frequency measurement: 0.1 Hz … 100 kHz (Default setting); Up/down counter/signal outputs (DO); Two up counters/16 bits/5 kHz

Data width

32-bit data; 8-bit control/status

Supply voltage (system)

5 VDC; via data contacts

Current consumption (5 V system supply)

70

Supply voltage (field)

24 VDC (-25 … +30 %); via power jumper contacts (power supply via blade contact; transmission via spring contact); Derating must be observed!

Rated surge voltage

1 kV

Number of incoming power jumper contacts

2

Number of outgoing power jumper contacts

2

Current carrying capacity (power jumper contacts)

10

Derating

Derating (supply voltage): Ambient temperatures under laboratory conditions: (−25 … +30 %); for −40 … +55 °C: 24 V (−25 … +20 %); for +55 … +70 °C: 24 V (−25 … +10 %); Lower limit in all temperature ranges: −27.5 % (including 15 % residual ripple)

Connection data

Connection technology: inputs / outputs

8 x CAGE CLAMP®

Connection type 1

Inputs/Outputs

Solid conductor

0.25 … 2.5 mm² / 24 … 14 AWG

Fine-stranded conductor

0.25 … 2.5 mm² / 24 … 14 AWG

Strip length

8 … 9 mm / 0.31 … 0.35 inches

Physical data

Width

12 mm / 0.472 inches

Height

100 mm / 3.937 inches

Depth

67.8 mm / 2.669 inches

Depth from upper-edge of DIN-rail

60.6 mm / 2.386 inches

Mechanical data

Mounting type

DIN-35 rail

Material data

Color

dark gray

Housing material

Polycarbonate; polyamide 6.6

Fire load

0.147

Weight

49.3

Conformity marking

CE

Environmental requirements

Ambient temperature (operation)

-40 … +70 °C

Surrounding air temperature (storage)

-40 … +85 °C

Protection type

IP20

Pollution degree (5)

2 per IEC 61131-2

Operating altitude

without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)

Mounting position

horizontal (standing/lying); vertical

Relative humidity (without condensation)

95

Relative humidity (with condensation)

Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)

Vibration resistance

per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373

Shock resistance

per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 50155, EN 61373

EMC immunity to interference

Per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26;
EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994

EMC emission of interference

per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5

Exposure to pollutants

Per IEC 60068-2-42 and IEC 60068-2-43

Permissible pollutant concentration H2S at a relative humidity < 75%

10

Permissible pollutant concentration SO 2 at a relative humidity < 75%

25

Manual
  • System Manual XTR

    Download
  • Counter Adjust /XTR

    Download
  • System Manual Series 750/753

    Download
Bid Text
  • 750-404/040-003

    Download
  • 750-404/040-003

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
System Description
  • 750 XTR Series I/O-System ‒ General Product Information

    Download
  • Overview on WAGO-I/O-SYSTEM 750 approvals

    Download
CAE data
  • EPLAN Data Portal 750-404/040-003

    Download
  • ZUKEN Portal 750-404/040-003

    Download
  • EPLAN Data Portal 750-404/040-003

    Download
CAD data
  • 2D/3D Models 750-404/040-003

    Download
Compliance Search
  • Environmental Product Compliance 750-404/040-003

    Download