Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

750-493 - 3-Phase Power Measurement; 480 VAC, 1 A

  • Brand: Wago
  • Product Code: 750-493
Description: The 750-493 3-Phase Power Measurement Module measures the electrical data in a three-phase supply network. The voltage is measured via network connection to L1, L2, L3 and N. The current of the three phases is fed to IL1, IL2, IL3 and IN via current transformers. The 750-493 Module transmits the root mean square values into the process image without requiring high computing power from the controller. For each phase, the effective power (P) and the energy consumption (W) are calculated by the module using the root mean square values for all measured voltages (V) and currents (I). For example, both the apparent power (S) and phase shift angle (φ) can be easily derived from these values. Therefore, the 750-493 Module provides comprehensive network analysis via fieldbus. Metrics, such as effective and apparent power consumption or load condition, enable the operator to optimize supply to a drive or machine. This can protect the installation from damage and failure.
Description: The 750-493 3-Phase Power Measurement Module measures the electrical data in a three-phase supply network. The voltage is measured via network connection to L1, L2, L3 and N. The current of the three phases is fed to IL1, IL2, IL3 and IN via current transformers. The 750-493 Module transmits the root mean square values into the process image without requiring high computing power from the controller. For each phase, the effective power (P) and the energy consumption (W) are calculated by the module using the root mean square values for all measured voltages (V) and currents (I). For example, both the apparent power (S) and phase shift angle (φ) can be easily derived from these values. Therefore, the 750-493 Module provides comprehensive network analysis via fieldbus. Metrics, such as effective and apparent power consumption or load condition, enable the operator to optimize supply to a drive or machine. This can protect the installation from damage and failure.
  • Available Quantity: 0

$521.40

Technical data

Number of measurement inputs

6 (3 voltage measurement inputs, 3 current measurement inputs)

Signal type

Power measurement

Signal form

Any periodic signals (considering the threshold frequencies)

Resolution [bit]

16

Data width

2 x 48-bit data; 2 x 24-bit control/status (optional)

Voltage path input resistance (typ.)

1071

Current path input resistance (typ.)

22 mΩ

Reference for measurement error

AC current/voltage

Measurement error, reference temperature

25

Measurement error, deviation max (upper-range value) ≤±

0.5

Measurement current (max.)

1 A

Measurement voltage (max.)

500 VAC, 3 phases

Measurement cycle time

Adjustable measuring cycle time for Min_Max_Values

Frequency range with activated DC filter

10 … 2000 Hz

Frequency range with deactivated DC filter

0 … 2000 Hz

Frequency range (mains frequency)

45 … 65 Hz

Limit frequency

7.2

Rated voltage

ULN = 277 V AC/DC; ULL = 480 VAC

Calculated values

Active power, active energy, grid frequency, cos ϕ

Measurement components

Evaluating

Measurement method

True RMS measurement

Configuration options

WAGO-I/O-CHECK

CODESYS Library

e!COCKPIT

Supply voltage (system)

5 VDC; via data contacts

Current consumption (5 V system supply)

100

Isolation

4 kV system/field

Rated surge voltage

4 kV

Connection data

Connection technology: inputs / outputs

8 x CAGE CLAMP®

Connection type 1

Inputs/Outputs

Solid conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Fine-stranded conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Strip length

8 … 9 mm / 0.31 … 0.35 inches

Physical data

Width

12 mm / 0.472 inches

Height

100 mm / 3.937 inches

Depth

67.8 mm / 2.669 inches

Depth from upper-edge of DIN-rail

60.6 mm / 2.386 inches

Mechanical data

Mounting type

DIN-35 rail

Material data

Color

light gray

Housing material

Polycarbonate; polyamide 6.6

Fire load

0.942

Weight

48.5

Conformity marking

CE

Environmental requirements

Ambient temperature (operation)

0 … +55 °C

Surrounding air temperature (storage)

-25 … +85 °C

Protection type

IP20

Pollution degree (5)

2 per IEC 61131-2

Operating altitude

0 … 2000 m / 0 … 6562 ft

Mounting position

horizontal (standing/lying); vertical

Relative humidity (without condensation)

95

Vibration resistance

per IEC 60068-2-6

Shock resistance

15g per IEC 60068-2-27

EMC immunity to interference

per EN 61000-6-2

EMC emission of interference

per EN 61000-6-3

Exposure to pollutants

Per IEC 60068-2-42 and IEC 60068-2-43

Permissible pollutant concentration H2S at a relative humidity < 75%

10

Permissible pollutant concentration SO 2 at a relative humidity < 75%

25

Manual
  • System Manual WAGO I/O System 750 / 753

    Download
  • 3-Phase Power Measurement Module

    Download
  • System Manual Series 750/753

    Download
Bid Text
  • 750-493

    Download
  • 750-493

    Download
System Description
  • Use in Hazardous Environments

    Download
  • 750/753 Series I/O-System ‒ General Product Information

    Download
  • Overview on WAGO-I/O-SYSTEM 750 approvals

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
Application Note CoDeSys 2.3
  • Application Note PowerMeasurement_03 Library

    Download
Library
  • Libraries for Building Automation CODESYS 2.3

    Download
CAD data
  • 2D/3D Models 750-493

    Download
CAE data
  • EPLAN Data Portal 750-493

    Download
  • WSCAD Universe 750-493

    Download
  • ZUKEN Portal 750-493

    Download
Device Driver
  • WAGO USB Service Kabel Treiber / Serie 750 und 857

    Download
Compliance Search
  • Environmental Product Compliance 750-493

    Download