Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

750-495/000-002 - 3-Phase Power Measurement; 690 VAC Rogowski coils

  • Brand: Wago
  • Product Code: 750-495/000-002
Description: The 750-495 3-Phase Power Measurement Module measures electrical data in a three-phase supply network. The voltage is measured via network connection to L1, L2, L3 and N. The current of the three phases is fed to IL1, IL2, IL3 and IN (two clamping points each +,-) via current transformers. The 750-495 Module transmits metrics (e.g., reactive/apparent/effective power, energy consumption, power factor, phase angle, frequency, over-/undervoltage) directly into the process image, without requiring high computing power from the controller. Both comprehensive metrics and harmonic analysis up to the 41st harmonic permit extensive network analysis via the fieldbus.Metrics allow the operator to optimize the supply to a drive or machine, protecting the system from damage and failure. Insulation failures can be detected and prevented via current measurement performed in the neutral conductor. The 4-quadrant display indicates the type of load (inductive, capacitive) and whether it is an energy consumer or producer.
Description: The 750-495 3-Phase Power Measurement Module measures electrical data in a three-phase supply network. The voltage is measured via network connection to L1, L2, L3 and N. The current of the three phases is fed to IL1, IL2, IL3 and IN (two clamping points each +,-) via current transformers. The 750-495 Module transmits metrics (e.g., reactive/apparent/effective power, energy consumption, power factor, phase angle, frequency, over-/undervoltage) directly into the process image, without requiring high computing power from the controller. Both comprehensive metrics and harmonic analysis up to the 41st harmonic permit extensive network analysis via the fieldbus.Metrics allow the operator to optimize the supply to a drive or machine, protecting the system from damage and failure. Insulation failures can be detected and prevented via current measurement performed in the neutral conductor. The 4-quadrant display indicates the type of load (inductive, capacitive) and whether it is an energy consumer or producer.
  • Available Quantity: 0

$822.40

Technical data

Number of measurement inputs

7 (3 Spannungsmesseingänge, 4 differentielle Strommesseingänge)

Signal type

Power measurement

Signal form

Any periodic signals (considering the threshold frequencies)

Resolution [bit]

24

Data width

2 x 128-bit data; 2 x 64-bit control/status

Voltage path input resistance (typ.)

1429

Current path input resistance (typ.)

44 kΩ

Reference for measurement error

AC current/voltage

Measurement error, reference temperature

25

Measurement error, deviation max (upper-range value) ≤±

0.5

Measurement current (max.)

Rogowski Coils RT500/RT2000

Measurement cycle time

Adjustable for arithmetic mean value, Min_Max_Values

Frequency range (mains frequency)

45 … 65 Hz

Frequency range (harmonics analysis)

0 … 3300 Hz

Limit frequency

15.9

Rated voltage

VLN = 400 VAC; VLL = 690 VAC

Calculated values

Line-to-line voltage, power output, energy, power factors, mains frequency, harmonic analysis (up to the 41st harmonic), THD

Measurement components

Evaluating

Measurement method

True RMS measurement

Configuration options

WAGO-I/O-CHECK

CODESYS Library

e!COCKPIT

Supply voltage (system)

5 VDC; via data contacts

Current consumption (5 V system supply)

100

Isolation

6 kV system/field

Rated surge voltage

6 kV

Connection data

Connection technology: inputs / outputs

16 x CAGE CLAMP®

Connection type 1

Inputs/Outputs

Solid conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Fine-stranded conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Strip length

8 … 9 mm / 0.31 … 0.35 inches

Physical data

Width

24 mm / 0.945 inches

Height

100 mm / 3.937 inches

Depth

67.8 mm / 2.669 inches

Depth from upper-edge of DIN-rail

60.6 mm / 2.386 inches

Mechanical data

Mounting type

DIN-35 rail

Material data

Color

light gray

Housing material

Polycarbonate; polyamide 6.6

Fire load

1.947

Weight

98.1

Conformity marking

CE

Environmental requirements

Ambient temperature (operation)

0 … +55 °C

Surrounding air temperature (storage)

-25 … +85 °C

Protection type

IP20

Pollution degree (5)

2

Operating altitude

0 … 2000 m / 0 … 6562 ft

Mounting position

horizontal (standing/lying); vertical

Relative humidity (without condensation)

95

Vibration resistance

4g per IEC 60068-2-6

Shock resistance

15g per IEC 60068-2-27

EMC immunity to interference

per EN 61000-6-2

EMC emission of interference

per EN 61000-6-3

Exposure to pollutants

Per IEC 60068-2-42 and IEC 60068-2-43

Permissible pollutant concentration H2S at a relative humidity < 75%

10

Permissible pollutant concentration SO 2 at a relative humidity < 75%

25

Manual
  • System Manual WAGO I/O System 750 / 753

    Download
  • 3-Phase Power Measurement Module

    Download
  • System Manual Series 750/753

    Download
Bid Text
  • 750-495/000-002

    Download
  • 750-495/000-002

    Download
System Description
  • Overview on WAGO-I/O-SYSTEM 750 approvals

    Download
  • 750/753 Series I/O-System ‒ General Product Information

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
Library
  • Function block description PowerMeasurement_495_02.lib

    Download
CAD data
  • 2D/3D Models 750-495/000-002

    Download
CAE data
  • EPLAN Data Portal 750-495/000-002

    Download
  • WSCAD Universe 750-495/000-002

    Download
  • ZUKEN Portal 750-495/000-002

    Download
  • EPLAN Data Portal 750-495/000-002

    Download
  • WSCAD Universe 750-495/000-002

    Download
Compliance Search
  • Environmental Product Compliance 750-495/000-002

    Download