Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

750-613/040-000 - System Power Supply; 24 VDC; Extreme

  • Brand: Wago
  • Product Code: 750-613/040-000
Description: This internal system supply module increases the capacity of the system supply by 2 A for fieldbus nodes with high current requirements (sum of the internal current consumption of the I/O modules). If required, additional system supply modules with bus power supply can be used. The module also supplies field-side power to the adjacent modules via the power jumper contacts. The device is ideal for operation in extreme environments thanks to: An extended temperature range Greater immunity to impulse voltages and electromagnetic interference Higher vibration and shock resistance
Description: This internal system supply module increases the capacity of the system supply by 2 A for fieldbus nodes with high current requirements (sum of the internal current consumption of the I/O modules). If required, additional system supply modules with bus power supply can be used. The module also supplies field-side power to the adjacent modules via the power jumper contacts. The device is ideal for operation in extreme environments thanks to: An extended temperature range Greater immunity to impulse voltages and electromagnetic interference Higher vibration and shock resistance
Technical data

Signal type

Voltage

Signal type (voltage)

24 VDC

Supply voltage (system)

24 VDC (-25 … +30 %); via pluggable connector (CAGE CLAMP® connection)

Total current (system supply)

2,000

Supply voltage (field)

24 VDC (-25 … +30 %); via power jumper contacts (power supply via CAGE CLAMP® connection; transmission via spring contact); Derating must be observed!

Input current (typ.) at nominal load (24 V)

500

Power supply efficiency (typ.) at nominal load (24 V)

90

Rated surge voltage

1 kV

Number of outgoing power jumper contacts

2

Current carrying capacity (power jumper contacts)

10

Derating

Derating (supply voltage): Ambient temperatures under laboratory conditions: (−25 … +30 %); for −40 … +55 °C: 24 V (−25 … +20 %); for +55 … +70 °C: 24 V (−25 … +10 %); Lower limit in all temperature ranges: −27.5 % (including 15 % residual ripple)

Connection data

Connection technology: field supply

4 x CAGE CLAMP®

Connection technology: system supply

2 x CAGE CLAMP®

Connection type 1

System/field supply

Solid conductor

0.25 … 2.5 mm² / 24 … 14 AWG

Fine-stranded conductor

0.25 … 2.5 mm² / 24 … 14 AWG

Strip length

8 … 9 mm / 0.31 … 0.35 inches

Physical data

Width

12 mm / 0.472 inches

Height

100 mm / 3.937 inches

Depth

67.8 mm / 2.669 inches

Depth from upper-edge of DIN-rail

60.6 mm / 2.386 inches

Mechanical data

Mounting type

DIN-35 rail

Material data

Color

dark gray

Housing material

Polycarbonate; polyamide 6.6

Fire load

0.159

Weight

55

Conformity marking

CE

Environmental requirements

Ambient temperature (operation)

-40 … +70 °C

Surrounding air temperature (storage)

-40 … +85 °C

Protection type

IP20

Pollution degree (5)

2 per IEC 61131-2

Operating altitude

without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)

Mounting position

horizontal (standing/lying); vertical

Relative humidity (without condensation)

95

Relative humidity (with condensation)

Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)

Vibration resistance

per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373

Shock resistance

per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 50155, EN 61373

EMC immunity to interference

Per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26;
EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994

EMC emission of interference

per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5

Exposure to pollutants

Per IEC 60068-2-42 and IEC 60068-2-43

Permissible pollutant concentration H2S at a relative humidity < 75%

10

Permissible pollutant concentration SO 2 at a relative humidity < 75%

25

Manual
  • System Manual XTR

    Download
  • 24 V DC Bus Power Supply /XTR

    Download
Bid Text
  • 750-613/040-000

    Download
  • 750-613/040-000

    Download
System Description
  • Overview on WAGO-I/O-SYSTEM 750 approvals

    Download
  • 750 XTR Series I/O-System ‒ General Product Information

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
CAD data
  • 2D/3D Models 750-613/040-000

    Download
CAE data
  • EPLAN Data Portal 750-613/040-000

    Download
  • WSCAD Universe 750-613/040-000

    Download
  • ZUKEN Portal 750-613/040-000

    Download
  • WSCAD Universe 750-613/040-000

    Download
  • EPLAN Data Portal 750-613/040-000

    Download
Compliance Search
  • Environmental Product Compliance 750-613/040-000

    Download