750-672 - Stepper Controller; 70 VDC; 7.5 A
- Brand: Wago
- Product Code: 750-672
- Available Quantity: 0
$992.40
Technical data
Device-specific | Inputs (preset): DI 1: Drive stop, DI 2: Reference input, DI 3: Jog switch in positive direction, DI 4: Jog switch in negative direction, DI 5: Limit switch in positive direction, DI 6: Limit switch in negative direction, Outputs (preset): DO 1: Target reached, DO 2: Error, Inputs and outputs can be freely reconfigured. |
Number of digital outputs | 2 |
Input filter | 100 µs, software filter can be connected |
Input current (typ.) | 2.8 mA |
Output current per channel | 0.5 |
Output current | short-circuit-protected |
Switching frequency (max.) | 5 Hz; Inductive load per IEC 947-5-1, DC 13 |
Load type | Resistive load, inductive load (max. 2 H), lamps |
Output current (max.) (motor) | 2 x 5.0 A (2 x 7.5 A transient) |
Output voltage | Control voltage: 24 VDC (-25 % … +30 %); Closed current: 120 mA + 2 x 0.5 A (DO1, DO2, load-dependent); Motor voltage: 55 VDC nominal value; Absolute upper limit: 71.5 V; Absolute lower limit: 18 V; Closed current (typ.) = 5 mA; Protection via external fuse 5 A |
Voltage range for signal (0) | −3 … +5 VDC |
Voltage range for signal (1) | 15 … 30 VDC |
Diagnostics | Overcurrent, short circuit or ground fault, overtemperature, supply voltage monitoring, motor wire break |
Resolution | 15 bits + 16 bit prescaler; 64 microsteps per full step |
Stepper resolution | 23 bits + sign bit |
Load type of switching frequency | Inductive load per IEC 947-5-1, DC 13 |
Stepper frequency (full-step) max. | 7,812 |
Data width | 12-byte input/output |
Protection | Short circuit monitoring of motor connections: Winding short circuit and short circuit to 0 V and 24 V 24 V supply: Reverse voltage protection Motor supply: Reverse voltage protection via external fuse |
Functions | Positioning, sin²-shaped ramps, setpoint change on the fly, rotational speed control |
Supply voltage (system) | 5 VDC; via data contacts |
Current consumption (5 V system supply) | 70 |
Isolation | 500 V system/field |
Connection data
Connection technology: inputs / outputs | 24 x CAGE CLAMP® |
Connection type 1 | Inputs/Outputs |
Solid conductor | 0.08 … 1.5 mm² / 28 … 14 AWG |
Fine-stranded conductor | 0.08 … 1.5 mm² / 28 … 14 AWG |
Strip length | 5 … 6 mm / 0.2 … 0.24 inches |
Connection requirement (permissible cable length) | 30 |
Connection requirement (permissible cable type) | Motor connection: shielded |
Note (conductor cross-section) | 14 AWG: THHN, THWN |
Physical data
Width | 48 mm / 1.89 inches |
Height | 100 mm / 3.937 inches |
Depth | 69.8 mm / 2.748 inches |
Depth from upper-edge of DIN-rail | 62.6 mm / 2.465 inches |
Mechanical data
Mounting type | DIN-35 rail |
Material data
Color | light gray |
Housing material | Polycarbonate; polyamide 6.6 |
Fire load | 2.42 |
Weight | 175 |
Conformity marking | CE |
Environmental requirements
Ambient temperature (operation) | 0 … +55 °C |
Surrounding air temperature (storage) | -25 … +85 °C |
Protection type | IP20 |
Pollution degree (5) | 2 per IEC 61131-2 |
Operating altitude | 0 … 2000 m / 0 … 6562 ft |
Mounting position | horizontal (standing/lying); vertical |
Relative humidity (without condensation) | 95 |
Vibration resistance | per IEC 60068-2-6 |
Shock resistance | 15g per IEC 60068-2-27 |
EMC immunity to interference | per EN 61000-6-2 |
EMC emission of interference | per EN 61000-6-3 |
Exposure to pollutants | Per IEC 60068-2-42 and IEC 60068-2-43 |
Permissible pollutant concentration H2S at a relative humidity < 75% | 10 |
Permissible pollutant concentration SO 2 at a relative humidity < 75% | 25 |