Technical data
Control circuit

Nominal input voltage UN

DC 48 V

Load circuit

Number of changeover contacts

1

Contact material (relay)

AgSnO2

Limiting continuous current

6 A

Inrush current (resistive) max.

(AC) 20 A / 0.02 s

Switching voltage (max.)

AC 250 V

Switching power (resistive) max.

AC 1500 VA; DC (see load limit curve)

Switching capacity

AC-15: 3 A / AC 250 V; DC-13: 2 A / DC 24 V

Recommended minimum load

10 V / 10 mA; 24 V / 1 mA

Pull-in time (typ.)

8

Drop-out time (typ.)

4

Bounce time (typ.)

3.5

Electrical life (NO; resistive load; 23 °C)

50 x 103 switching operations

Mechanical life

5 x 106 switching operations

Switching frequency with/without load (max.)

6 min-1 / 180 min-1

Safety and protection

Dielectric strength (control/load circuit) (AC, 1 min)

4 kVrms

Dielectric strength (open contact) (AC, 1 min)

1 kVrms

Protection type

IP20

Notes

Note

  • The 60 VDC basic relay must be used for 60 VDC, 110 VDC, 220 VDC and 115 VAC/DC, 230 VAC/DC relay modules.
  • To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.
  • 30 VDC switching voltages and 50 mA currents must not be exceeded for gold-plated basic relays. Higher switching power eventually evaporates the gold layer. The resulting deposits in the housing may reduce service life.

Physical data

Width

5 mm / 0.197 inch

Height from the surface

15 mm / 0.591 inch

Depth

28 mm / 1.09 inch

Mechanical data

Mounting type

Pluggable module

Material data

Weight

4.7

Environmental requirements

Ambient temperature (operation at UN)

-40 … 85 °C

Surrounding air temperature (storage)

-40 … +85 °C

Relative humidity

5 … 85 % (no condensation permissible)

Operating altitude (max.)

2000

Standards and specifications

Standards/specifications

EN 61810-1

EN 61373

VDE

UR

Bid Text
  • 857-154

    Download
  • 857-154

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
CAE data
  • EPLAN Data Portal 857-154

    Download
  • WSCAD Universe 857-154

    Download
  • ZUKEN Portal 857-154

    Download
CAD data
  • 2D/3D Models 857-154

    Download
Compliance Search
  • Environmental Product Compliance 857-154

    Download