Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

101186145 - TQ 900-02

Description: Product type description:TQ 900-(1)(2)(1)111 NO contacts/1 NC contact131 NO contacts/3 NC contact222 NO contacts/2 NC contact022 NC contact044 NC contact
Description: Product type description:TQ 900-(1)(2)(1)111 NO contacts/1 NC contact131 NO contacts/3 NC contact222 NO contacts/2 NC contact022 NC contact044 NC contact
Productfeatures
  • 3 cable entries M 20 x 1.5
  • Metal enclosure
  • one-side operation / wire up to 50 m long
  • Position indicator
  • Robust design
  • Large wiring compartment
  • Twisting of towing eye not possible
  • External watertight collar
Data
Ordering data

Product type description

TQ 900-02

Article number (order number)

101186145

EAN (European Article Number)

4030661325927

eCl@ss number, version 9.0

27-27-06-07

eCl@ss number, version 11.0

27-27-06-07

eCl@ss number, version 12.0

27-27-06-07

ETIM number, version 7.0

EC002033

ETIM number, version 6.0

EC002033

Approvals - Standards

Certificates

TÜV

CCC

EAC

General data

Standards

IEC/EN 60947-5-1

Enclosure material

Zinc die-cast

Enclosure coating material

painted

Material of the contacts, electrical

Silver

Material of the cover

Glass-fibre, thermoplastic

Length of the wire, minimum

5 m

Length of the wire, maximum

50 m

Gross weight

1,225 g

General data - Features

Indicator lamp

Yes

Number of openers

2

Safety classification - Safety outputs

B

100,000 Operations

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Actuating force, maximum

200 N

Actuating travel

400 mm

Mechanical data - Connection technique

Type of connection

Screw terminals M20 x 1.5

Cable section, minimum

0.75 mm²

Cable section, maximum

1 x 2.5 mm²

Note (Cable section)

All indications including the conductor ferrules.

Mechanical data - Dimensions

Length of sensor

69.7 mm

Width of sensor

71.5 mm

Height of the Sensor, minimum

220.3 mm

Height of the Sensor, maximum

236.3 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Ambient conditions - Insulation values

Rated insulation voltage U

500 V

Rated impulse withstand voltage U

6 kV

Electrical data

Thermal test current

6 A

Utilisation category AC-15

230 VAC

Utilisation category AC-15

4 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

1 A

Switching element

Opener (NC)

Switching principle

Creep circuit element

Operating instructions and Declaration of conformity
  • TQ 900

    Download
BG-test certificate
  • TQ 900 / ZQ 900 (ACE)

    Download
  • TQ 900 / ZQ 900 (SIPL)

    Download
  • TQ 900 / ZQ 900 (SISS)

    Download
  • TraceParts

    Download
  • CADENAS

    Download