Description: High Performance AC Drives Induction & PM Motor Control 230, 460, 500, 600 volt models - 0.5 TO 350 HP - NEMA12 Packaging | 15 - 250HP Through Panel Mount Option NEMA 4X to 10HP (indoor rated) Printing Presses Extrusion & Coating Lines Automated Assembly Indexing & Registration Winders & Web Tension Material Handling Cranes & Hoists Textiles & Fibres Metals Industry Paper & Cement Mills Mining
Description: High Performance AC Drives Induction & PM Motor Control 230, 460, 500, 600 volt models - 0.5 TO 350 HP - NEMA12 Packaging | 15 - 250HP Through Panel Mount Option NEMA 4X to 10HP (indoor rated) Printing Presses Extrusion & Coating Lines Automated Assembly Indexing & Registration Winders & Web Tension Material Handling Cranes & Hoists Textiles & Fibres Metals Industry Paper & Cement Mills Mining
Features
    • Multiple Modes:
      • Closed Loop Vector for high performance
      • Open loop PM Motor control
      • Sensorless vector & V/Hz control
      • Open Loop PM Vector Control
    • Up to 200% torque at zero speed
    • Sensorless speed regulation better than 1%
    • Torque control
    • DC bus sharing
    • Safe Torque Off function
    • Output to 500Hz (V/F Mode), 100Hz (Vector Mode)
    • Built-in 100% rated DB transistor up to 350HP
    • Integral PI controller
    • drive.web savvy function block programming
    • Silent running with up to 32KHz switching
    • 200% starting torque
    • Bipolar 12 bit analog input (isolated +/-10V or 4-20mA)
    • ModbusRTU, RS485 port
    • CANopen port
    • Filters & DC chokes 25-250 HP
    • Single phase input up to 125 HP
    • Power loss ride through
    • Process control options
    • Programmable i/o
    • Hours run log & trip log
    • Cartridge fans for easy maintenance (NEMA12 drives)
    • UL, CE, C-Tick on all models
    • Options:
      • Encoder feedback
      • Additional basic & smarty i/o options
      • EIP, Modbus TCP/IP, Profibus, DeviceNet, BACnet
      • Memory stick with bluetooth interface
      • Remote keypad
      • 2Khz output in V/Hz mode
      • OLED text display
      • Through panel mount for NEMA 12 versions
Dimensions
  • Frame Size 2 2 3 3 4 5 6 7 8
    Protection IP20 NEMA 4X (IP66) IP20 NEMA 4X (IP66) NEMA 12 (IP55) NEMA 12 (IP55) NEMA 12 (IP55) NEMA 12 (IP55) IP20
    Height (ins) 8.7” 10.1” 10.3” 12.2” 17.7” 21.3” 34.1” 50.4” 40”
    Height (mm) 221 257 261 310 450 540 865 1280 995
    Width (ins) 4.4” 7.4” 5.2” 8.3” 6.8” 9.3” 13” 13” 19”
    Width (mm) 112 188 131 211 171 235 330 330 482
    Depth (ins) 7.3” 9.4” 8.1” 10.5” 9.9” 10.7” 13.0” 14.2” 19”
    Depth (mm) 185 239 205 266 252 270 330 360 480
    Weight (lbs) 4 10.6 7.7 17 25.4 50.7 121 196.2 282
    Weight (kg) 1.8 4.8 3.5 7.7 11.5 23 55 89 128
Specifications
Input Ratings

Supply Voltage

200 – 240 ± 10% 380 – 480 ± 10% 500 – 600 ± 10%

Supply Frequency

48 – 62 Hz

Displacement PF

> 0.98

Phase Imbalance

3% Maximum allowed

Inrush Current

< Rated current

Power Cycles

120 per hour max, evenly spaced
Output Ratings

Power Output

230V, 1-ph in: 1-3 HP (0.75-2.2 kW) 230V, 3-ph in: 1-120 HP (0.75-90 kW) 400V, 3-ph in: 0.75-160kW 460V, 3-ph in: 1-350 HP 600V, 3-ph in; 1-150 HP

Overload Capacity

150% for 60 secs, 200% for 4 secs.

Output Frequency

0-500Hz in V/Hz mode (0.1 Hz res) (optional 2KHz) 0-100Hz in vector mode
Ambient Ratings

Temperature

Storage: -40°C to 60°C Operating:

Altitude

Up to 1000m ASL without de-rating Up to 2000m Max UL Approved Up to 4000m Max (non UL) Above 1000m, de-rate 1% per 100m

Humidity

95% non-condensing
Enclosures

Ingress Protection

IP20 – Frame sizes 2 & 3 IP40 (NEMA 1) – Frame size 8 IP55 (NEMA 12) – Frame sizes 4 to 7 IP66 (NEMA 4X) – Optional sizes 2 & 3
Programming

Keypad

Standard: Built-in keypad Optional: Remote keypad Optistick memory stick

USB or Ethernet Option

software

Display

Bright Red LED (IP20 Enclosure) Bright Green OLED text (NEMA12, NEMA4X, and Size 8 Enclosures)
Control

Control Modes

Closed Loop (encoder) speed control Closed Loop (encoder) torque control Open Loop PM vector control Sensorless vector speed control V/F Voltage vector Energy optimized V/F

Modulation

4 – 32 kHz effective

Stop Mode

Ramp to stop – adjustable 0.1-600 secs Safe Torque Off mode

Braking

Motor flux braking (DC injection) Built in brake transistor

Skip Frequency

Single point user adjustable

Analog Setpoint Control

0-10v, 10-0v, ±10v 0-20mA, 20-0mA, 4-20mA, 20-4mA

Digital Setpoint Control

Keypad ModbusRTU CANopen

Automation

Optional Ethernet distributed control + programmable control, extra i/o, operator stations

Communications Options

, ModbusTCP, EIP, DeviceNet, Profibus
i/o Specification

Power Supply

24VDC, 100mA short protected 10VDC, 5mA for setpoint potentiometer

Programmable Inputs

3 x Digital 10 to 30 VDC, response < 4ms 2 x Analog/digital

Programmable Outputs

2 x Analog, 0-10V, 0-20mA, 4-20mA 2 x Relay NO, 6A @ 250VAC, 5A @ 30VDC
Control & Monitoring

PID

Internal PID with feedback display

Fault Memory

Last 4 trips stored with time stamp

Data Logging

Current, temperature, DC Bus volts prior to trip

Maintenance Indicator

Service life monitor with user adjustable interval

Monitoring

Hours run Resettable and non-resettable kWh meters
P2 Options

OPT2-ENCOD-IN Encoder feedback module

OPT2-OPORT-IN Remote keypad & display

OPT2-OPPAD-IN Remote keypad w/OLED display

Accessories
  • Bardac_P2_Encod_Option_User_Guide_v1.1.pdf

    Download
  • optipad_user_guide_v1pt00.pdf

    Download
  • optiport2_user_guide_v1pt00.pdf

    Download
  • optistick_user_guide_v2pt00.pdf

    Download
Application Notes
  • Bardac_AN_CAN-Bus-Operation_v1.0.pdf

    Download
  • Bardac_AN_Drives-On-Generator-Supplies_v1.0.pdf

    Download
  • Bardac_AN_Mounting-Drives-In-Control-Panels_v1.0.pdf

    Download
  • Bardac_AN_Using-Multiple-Motors-in-Parallel_v1.0.pdf

    Download
Brochures
  • Bardac_P2_Solar_Pump_Brochure_v1.05_HighRes.pdf

    Download
  • Bardac_P2_Solar_Pump_Brochure_v1.05_LowRes.pdf

    Download
Drawings
  • Bardac_P2_V3_IP20_Size2_OutlineDrawings.zip

    Download
  • Bardac_P2_V3_IP20_Size2_STEP.zip

    Download
  • Bardac_P2_V3_IP20_Size3_OutlineDrawings.zip

    Download
  • Bardac_P2_V3_IP20_Size3_STEP.zip

    Download
  • Bardac_P2_V3_IP20_Size4_OutlineDrawings.zip

    Download
  • Bardac_P2_V3_IP20_Size4_STEP.zip

    Download
  • Bardac_P2_V3_IP20_Size5_OutlineDrawings.zip

    Download
  • Bardac_P2_V3_IP20_Size5_STEP.zip

    Download
  • Bardac_P2_V3_IP20_Size8_OutlineDrawings.zip

    Download
  • Bardac_P2_V3_IP20_Size8_STEP.zip

    Download
  • Bardac_P2_V3_IP55_Size4_OutlineDrawings.zip

    Download
  • Bardac_P2_V3_IP55_Size4_STEP.zip

    Download
  • Bardac_P2_V3_IP55_Size5_OutlineDrawings.zip

    Download
  • Bardac_P2_V3_IP55_Size5_STEP.zip

    Download
  • Bardac_P2_V3_IP55_Size6_OutlineDrawings.zip

    Download
  • Bardac_P2_V3_IP55_Size6_STEP.zip

    Download
  • Bardac_P2_V3_IP55_Size7_OutlineDrawings.zip

    Download
  • Bardac_P2_V3_IP55_Size7_STEP.zip

    Download
  • Bardac_P2_V3_IP66_Size2_OutlineDrawings.zip

    Download
  • Bardac_P2_V3_IP66_Size2_STEP.zip

    Download
  • Bardac_P2_V3_IP66_Size3_OutlineDrawings.zip

    Download
  • Bardac_P2_V3_IP66_Size3_STEP.zip

    Download
  • Bardac_P2_V3_Series_AllDrawings_AllSTEP.zip

    Download
Manuals
  • Bardac_P2_Series_Manual_v3.01.pdf

    Download
  • Bardac_P2_Solar_Pump_Manual_v1.02.pdf

    Download
Presentations
  • Bardac_P2_Series_Overview_Presentation_v1.1_HighRes.pdf

    Download
  • Bardac_P2_Series_Overview_Presentation_v1.1_LowRes.pdf

    Download
  • Bardac_P2_Series_Overview_Presentation_v1.1_Powerpoint.pptx

    Download
  • Bardac_P2_Series_Solar_Pump_Presentation_v1.0.pdf

    Download
  • Bardac_P2_Series_Solar_Pump_Presentation_v1.0_Powerpoint.pptx

    Download