- Built-in Condensate Evaporator eliminates need for draining condensate under normal operating conditions. May not be adequate in extremely high humidity with open or leaky enclosure. Overflow condensate drain fitting and hose are included.
- CFC-free R134a Refrigerant is used
- The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
- Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
- Epoxy-Coated Evaporator Coils
- All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
- All units are fully gasketed for tight, leak-proof installation, in compliance with the NEMA 12 Enclosure Ratings.
- All models feature a programmable temperature alarm to alert if early action is required.
- All models feature a programmable thermostat, allowing more accurate and versatile performance features.
- A plate or plenum needed to replace older Kooltronic or competitor units.
- Where light weight and/or compatibility with appearance of aluminum enclosures are required. Unpainted Type 5052 is standard. Other types and ultraviolet-resistant baked powder finish are available.
- This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
- Condensate evaporator kits are available for attachment to the bottom of Air-Cooled Panel Mounted Air Conditioners. Condensate is collected, vaporized and discharged to the surrounding air. All units include a safety overflow drain which discharges excessive condensate when required. Overflow may occur when cabinets are poorly sealed, or when cabinet doors are frequently opened, permitting the invasion of moisture-laden air.
- This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
- Heavy-gauge steel lifting eyes, attached to the side panels, assist in positioning units.
- M-Tab Mounting (for existing retrofits)
- An optional feature for models with Programmable Thermostat, Remote Monitoring provides temperature data for warning of early action required.,Accomplished through a Hot Key connection from the Programmable Thermostat to a monitoring system (not supplied) that is ModBus-RTU compatible (i.e. XWEB500/3000/300) via an external 2-position terminal block.
- Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
- All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
- For outdoor installations subject to invasion by rain, snow or windblown dirt, special deflectors shield the condenser air inlet and outlet ports. Air conditioners or heat exchangers installed outdoors may also require special exterior paint. NOTE: Units using the Weather Protection Kit are not UL Listed.
Air Conditioner Quick-Sheet [105Kb]
Condensate Evaporator Kits [241Kb]
Condensation and Electronics [3983Kb]
Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
Hazardous Location Series White Paper [234Kb]
Increasing the Lifespan and Reliability of Electrical Components [212Kb]
Slimkool Series Flyer [584Kb]
Narrow-Mini Series Information Sheet [138Kb]
Kooltronic Custom Capabilities Flyer [2194Kb]
Kooltronic Custom Cooling Medical Flyer [211Kb]
Kooltronic Design Guide/Catalog (220 pages) [229400Kb]
Kooltronic Refrigeration System Manufacturing [55Kb]
Kooltronic Standard Warranty [55Kb]
Kooltronic Unit Longevity Press Release [167Kb]
NEMA Enclosure Ratings [91Kb]
Short-Form Catalog (16 pages) [897Kb]
Airflow Switch Data Sheet [159Kb]
Laboratory Environmental Testing Services [157Kb]
Powder Paint Application Facilities Flyer [165Kb]
K_A4C_HS, KA4C_MMT, K_A4C_HTT, KA4C_NP17, KA4C_NM Wiring Diagram (Ladder)for NP17 units w/ s/n's up to A17A0030 & NP17 units w/ s/n's up to M16A4171 [69Kb]
K2A4C_NP17, K2A4C2.0NM & K2A4C_HTT Wiring Diagram (Ladder) for NP17 units w/ s/n's up to M16A4171 [67Kb]
K2A4C2.5NM/56 Wiring Diagram (Ladder) [86Kb]
K2AC2.5NM/50-1 Wiring Diagram (Ladder) [72Kb]
KA4C0.0NM Wiring Diagram (Point-to-Point) [59Kb]
KA4C2.0NM, KA4C_NP17, KA4C_MMT, KA4C_HTT Wiring Diagram (Ladder) for Micro-Mini units w/ s/n's up to A17A0030 [60Kb]
KA4C2.5NMLY Wiring Diagram (Ladder w/ DIXELL) (NEW) [39Kb]
KA4C2.5NMLY Wiring Diagram (Point-to-Point w/DIXELL) (NEW) [58Kb]
KA4C2.5NMLY Wiring Diagram (Point-to-Point) [50Kb]
KAC1.5NM/50-1 Wiring Diagram (Ladder) [72Kb]
KAC1.5NM/56 Wiring Diagram (Ladder) [68Kb]
KAC2.5NM-X118 Wiring Diagram (Ladder) [58Kb]
KAC2.5NM/56 Wiring Diagram (Ladder) [64Kb]
Narrow-Mini & Micro-Mini Wiring Diagram (Ladder) for Micro-Mini units w/ s/n's up to A17A0030 [76Kb]
Narrow-Mini KA4C-NML Wiring Diagram (Point-to-Point) [61Kb]