Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

KA4C2DP17L - Profile Series DP17

Description:
Data
Built-in Condensate Evaporator
  • Built-in Condensate Evaporator eliminates need for draining condensate under normal operating conditions. May not be adequate in extremely high humidity with open or leaky enclosure. Overflow condensate drain fitting and hose are included.
CFC-Free Refrigerant
  • CFC-free R134a Refrigerant is used
Closed-Loop Cooling
  • The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
Compressor Short Cycle Protector
  • Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
Epoxy-Coated Condenser Coil
  • This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Shell or Integrity NEMA 4/4X Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
Mounts Internally or Externally
  • The Profile Series Air Conditioners have been engineered to be mounted either outside or inside of an enclosure, offering an unprecedented degree of flexibility. Air conditioners are traditionally mounted on the outside of an enclosure because space inside an enclosure is at a premium. The dimensions of the Profile Series make the option of internal mounting a reality, which allows the unit to fit into spaces previously too small for an air conditioner. With such a narrow depth, the Profile Series is the thinnest line of indoor/outdoor air conditioners Kooltronic has ever developed.
NEMA 12 & 3R Ratings Maintained (UL50)
  • All units are fully gasketed for tight, leakproof installation, in compliance with the NEMA 12 and 3R Enclosure Ratings.
Programmable Temperature Alarm
  • All models feature a programmable temperature alarm to alert if early action is required.
Programmable Thermostat
  • All models feature a programmable thermostat, allowing more accurate and versatile performance features.
Adapter
  • A plate or plenum needed to replace older Kooltronic or competitor units.
Enclosure Heater
  • Eliminates damaging condensation, increasing reliability of electrical enclosure components.
Filter
  • All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
Filter Recoating Adhesive
  • This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
Internal Corrosion Protection
  • This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
Remote Monitoring
  • An optional feature for models with Programmable Thermostat, Remote Monitoring provides temperature data for warning of early action required.,Accomplished through a Hot Key connection from the Programmable Thermostat to a monitoring system (not supplied) that is ModBus-RTU compatible (i.e. XWEB500/3000/300) via an external 2-position terminal block.
Remote Thermostat Relay
  • Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
Replacement Filters
  • All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
2-D Drawing of the Mounting Plan
  • KA4C2DP17L 2D Drawing of the Mounting Plan [42Kb]

    Download
3-D Solid Model
  • KA4C2DP17L 3D Solid Model [3657Kb]

    Download
Data Sheet
  • Profile Series DP17 Product Data Sheet [170Kb]

    Download
GA Drawing
  • Profile Series DP17 General Arrangement Drawing (OLD) [98Kb]

    Download
  • Profile Series DP17 General Arrangement Drawing w/Prgm. T-stat [96Kb]

    Download
Installation Instructions
  • Profile Series DP17 Installation Instructions (2 pages) [249Kb]

    Download
Literature
  • Air Conditioner Quick-Sheet [105Kb]

    Download
  • Condensate Evaporator Kits [241Kb]

    Download
  • Condensation and Electronics [3983Kb]

    Download
  • Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]

    Download
  • Hazardous Location Series White Paper [234Kb]

    Download
  • Increasing the Lifespan and Reliability of Electrical Components [212Kb]

    Download
  • Slimkool Series Flyer [584Kb]

    Download
  • Profile Series Brochure (4 pages) [272Kb]

    Download
  • Kooltronic Custom Capabilities Flyer [2194Kb]

    Download
  • Kooltronic Custom Cooling Medical Flyer [211Kb]

    Download
  • Kooltronic Design Guide/Catalog (220 pages) [229400Kb]

    Download
  • Kooltronic Refrigeration System Manufacturing [55Kb]

    Download
  • Kooltronic Standard Warranty [55Kb]

    Download
  • Kooltronic Unit Longevity Press Release [167Kb]

    Download
  • NEMA Enclosure Ratings [91Kb]

    Download
  • Short-Form Catalog (16 pages) [897Kb]

    Download
  • Airflow Switch Data Sheet [159Kb]

    Download
  • Laboratory Environmental Testing Services [157Kb]

    Download
  • Powder Paint Application Facilities Flyer [165Kb]

    Download
Operator's Manual
  • KLLC100 Lead-Lag Controller [38Kb]

    Download
  • KLLC480 Lead-Lag Controller [79Kb]

    Download
  • Profile Series DP17 Operator's Manual [853Kb]

    Download
Wiring Diagram
  • Profile Series DP17 Wiring Diagram (Ladder) w/ Programmable T-stat [47Kb]

    Download
  • Profile Series DP17 Wiring Diagram (Point to Point) w/ Programmable T-stat [61Kb]

    Download
  • Profile Series DP17 Wiring Diagram (Point to Point) w/ Programmable T-stat [64Kb]

    Download
  • Profile Series DP17 Wiring Diagram (Point to Point) w/ Programmable T-stat [61Kb]

    Download
  • Profile Series KA4C2DP17L Wiring Diagram (Ladder) [50Kb]

    Download
  • Profile Series KA4C2DP17L Wiring Diagram (Ladder) [45Kb]

    Download
  • Profile Series KA4C2DP17L Wiring Diagram (Point-to-Point) [64Kb]

    Download
  • Profile Series KA4C2DP17LF Wiring Diagram (Point-to-Point) [63Kb]

    Download