K2A6C9HL48LV - Hazardous Location Series HL48LV
- Brand: Kooltronic
- Product Code: K2A6C9HL48LV
- All models UL Listed per 484, Special Purpose Air Conditioners. All models UL Recognized per NFPA 496: 2013, Purged and Pressurized Enclosures for Electrical Equipment. Meets NEC Class I Division 1, Groups A, B, C and D Hazardous Locations, when used with an approved Type X Purge System on the electrical enclosure. Meets NEC Class I Division 2, Groups A, B, C and D, Hazardous Locations when used with an approved Type Z Purge System on the electrical enclosures. Temperature Classification is T-4, 275°F/135°C.
- The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
- Protects the compressor from possible damage due to harmful short cycling, (frequent starting) where temperature controls enable the compressor to restart frequently or after a power interruption. These conditions could be due to low or fluctuating heat loads within the electrical enclosure or a power failure. The Compressor Short Cycle Protector will prevent the compressor from starting when it has been shut off for less than several minutes or the power was interrupted. By limiting the number of compressor starts per hour, the life of the compressor is prolonged. It is recommended where installations are subject to solar gain and or changes in the enclosure internal load due to the degree of usage of the equipment being cooled. It is also recommended where higher capacity units are specified in anticipation of the future addition of heat producing equipment being added to the enclosure.
- All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible. A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
- NOTE: Internal Corrosion Protection is a Standard Feature on NEMA 4X models only. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or Integrity NEMA 4/4X Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
- Maintains NEMA Type 12, 3R & 4/4X Enclosure Ratings.
- Allows user to attach auxiliary pressure supply.
- All models feature a programmable temperature alarm to alert if early action is required.
- All models feature a programmable thermostat, allowing more accurate and versatile performance features.
- Hazardous Location Series models are designed to withstand shock and vibration in two different planes for a minimum of 4 hours per plane at 1G acceleration.
- For applications in corrosive or other hostile environments such as those requiring Internal Corrosion Resistant Coatings, especially where chemical/moisture combinations are present.
- R410a, an HFC having zero ozone depleting potential.
- Eliminates damaging condensation, increasing reliability of electrical enclosure components.
- This compound is a superior product for recoating filters after washing. The adhesives penetrate dirt layers to keep the filter surface tacky for longer effective performance between washings.
- An optional feature for models with Programmable Thermostat, Remote Monitoring provides temperature data for warning of early action required.,Accomplished through a Hot Key connection from the Programmable Thermostat to a monitoring system (not supplied) that is ModBus-RTU compatible (i.e. XWEB500/3000/300) via an external 2-position terminal block.
- Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
- All KOOLTRONIC filters consist of a multi-layer grid of sturdy corrugated aluminum, securely held in a one-piece aluminum frame. Filters are required wherever air is drawn into an electronics enclosure or related cooling equipment to keep internal parts as clean as possible.,A non-drying adhesive coating traps a high percentage of particulate matter. These filters are reuseable, they may be washed and recoated with the appropriate filter recoating adhesive. Replacements are available for those which become damaged or otherwise non-serviceable.
Air Conditioner Quick-Sheet [105Kb]
Condensate Evaporator Kits [241Kb]
Condensation and Electronics [3983Kb]
Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
Hazardous Location Series White Paper [234Kb]
Increasing the Lifespan and Reliability of Electrical Components [212Kb]
Slimkool Series Flyer [584Kb]
Kooltronic Custom Capabilities Flyer [2194Kb]
Kooltronic Custom Cooling Medical Flyer [211Kb]
Kooltronic Design Guide/Catalog (220 pages) [229400Kb]
Kooltronic Refrigeration System Manufacturing [55Kb]
Kooltronic Standard Warranty [55Kb]
Kooltronic Unit Longevity Press Release [167Kb]
NEMA Enclosure Ratings [91Kb]
Short-Form Catalog (16 pages) [897Kb]
Airflow Switch Data Sheet [159Kb]
Laboratory Environmental Testing Services [157Kb]
Powder Paint Application Facilities Flyer [165Kb]
Hazardous Location Series HL48LV Wiring Diagram (Ladder) [49Kb]
Hazardous Location Series HL48LV Wiring Diagram (Ladder) [55Kb]
Hazardous Location Series HL48LV Wiring Diagram (Ladder) [52Kb]
Hazardous Location Series K2A6C9HL48LV Wiring Diagram (Point-to-Point) [82Kb]
Hazardous Location Series K2A6C9HL48LV Wiring Diagram (Point-to-Point) [80Kb]
Hazardous Location Series K2A6C9HL48LV Wiring Diagram (Point-to-Point) [82Kb]
Hazardous Location Series K2A6C9HL48LV Wiring Diagram (Point-to-Point) [78Kb]
Hazardous Location Series KA6C9HL48LV Wiring Diagram (Point-to-Point) [76Kb]
Hazardous Location Series KA6C9HL48LV Wiring Diagram (Point-to-Point) [78Kb]
Hazardous Location Series KA6C9HL48LV Wiring Diagram (Point-to-Point) [76Kb]
Hazardous Location Series KA6C9HL48LV Wiring Diagram (Point-to-Point) [79Kb]