Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

750-342 - Fieldbus Coupler ETHERNET; 1st Generation

  • Brand: Wago
  • Product Code: 750-342
Description: The ETHERNET TCP/IP Fieldbus Coupler supports a number of network protocols to send process data via ETHERNET TCP/IP. Trouble-free connection to local and global (LAN, Internet) networks is performed by observing the relevant IT standards. By using ETHERNET as a fieldbus, a uniform data transmission is established between factory and office. Moreover, the ETHERNET TCP/IP Fieldbus Coupler offers remote maintenance, i.e. processes can be controlled regardless of the location. Process data exchange is performed via MODBUS/TCP protocol. The fieldbus coupler detects all connected I/O modules and automatically creates a local process image. The HTML pages that are stored in the fieldbus coupler allow access to information on configuration, status, or I/O data of the ETHERNET TCP/IP fieldbus coupler. Only a standard WEB browser is required. Dynamic configuration of the IP addresses via a BootP server provides a flexible and easy way to configure the network.
Description: The ETHERNET TCP/IP Fieldbus Coupler supports a number of network protocols to send process data via ETHERNET TCP/IP. Trouble-free connection to local and global (LAN, Internet) networks is performed by observing the relevant IT standards. By using ETHERNET as a fieldbus, a uniform data transmission is established between factory and office. Moreover, the ETHERNET TCP/IP Fieldbus Coupler offers remote maintenance, i.e. processes can be controlled regardless of the location. Process data exchange is performed via MODBUS/TCP protocol. The fieldbus coupler detects all connected I/O modules and automatically creates a local process image. The HTML pages that are stored in the fieldbus coupler allow access to information on configuration, status, or I/O data of the ETHERNET TCP/IP fieldbus coupler. Only a standard WEB browser is required. Dynamic configuration of the IP addresses via a BootP server provides a flexible and easy way to configure the network.
  • Available Quantity: 0

$807.20

Technical data

Communication

Modbus (TCP, UDP)

ETHERNET

ETHERNET protocols

HTTP

BootP

Baud rate

10 Mbit/s

Bus segment length (max.)

100 m

Transmission medium

Twisted Pair S-UTP; 100 Ω; Cat. 5

Number of socket connections (max.)

1 HTTP; 3 MODBUS/TCP

Number of modules per node (max.)

64

Input and output process image (fieldbus) max.

512 bytes/512 bytes

Supply voltage (system)

24 VDC (-25 … +30 %); via pluggable connector (CAGE CLAMP® connection)

Current consumption (5 V system supply)

200

Total current (system supply)

1,800

Supply voltage (field)

24 VDC (-25 … +30 %); via power jumper contacts

Input current (typ.) at nominal load (24 V)

500

Power supply efficiency (typ.) at nominal load (24 V)

87

Isolation

500 V system/field

Number of outgoing power jumper contacts

3

Current carrying capacity (power jumper contacts)

10

Connection data

Connection technology: communication/fieldbus

Modbus TCP/UDP: 1 x RJ-45

Connection technology: field supply

6 x CAGE CLAMP®

Connection technology: system supply

2 x CAGE CLAMP®

Connection technology: device configuration

1 x Male connector; 4-pole

Connection type 1

System/field supply

Solid conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Fine-stranded conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Strip length

8 … 9 mm / 0.31 … 0.35 inches

Physical data

Width

50.5 mm / 1.988 inches

Height

100 mm / 3.937 inches

Depth

71.1 mm / 2.799 inches

Depth from upper-edge of DIN-rail

63.9 mm / 2.516 inches

Mechanical data

Mounting type

DIN-35 rail

Material data

Color

light gray

Housing material

Polycarbonate; polyamide 6.6

Fire load

3.829

Weight

175.8

Conformity marking

CE

Environmental requirements

Ambient temperature (operation)

0 … +55 °C

Surrounding air temperature (storage)

-25 … +85 °C

Protection type

IP20

Pollution degree (5)

2 per IEC 61131-2

Operating altitude

0 … 2000 m / 0 … 6562 ft

Mounting position

horizontal (standing/lying); vertical

Relative humidity (without condensation)

95

Vibration resistance

4g per IEC 60068-2-6

Shock resistance

15g per IEC 60068-2-27

EMC immunity to interference

per EN 61000-6-2, marine applications

EMC emission of interference

per EN 61000-6-4, marine applications

Exposure to pollutants

Per IEC 60068-2-42 and IEC 60068-2-43

Permissible pollutant concentration H2S at a relative humidity < 75%

10

Permissible pollutant concentration SO 2 at a relative humidity < 75%

25

Manual
  • System Manual WAGO I/O System 750 / 753

    Download
  • ETHERNET TCP/IP fieldbus coupler

    Download
  • System Manual Series 750/753

    Download
Bid Text
  • 750-342

    Download
  • 750-342

    Download
System Description
  • 750/753 Series I/O-System ‒ General Product Information

    Download
  • Overview on WAGO-I/O-SYSTEM 750 approvals

    Download
  • Use in Hazardous Environments

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
Application note, other
  • Anbindung an MCPS Datenerfassungs Software (a116400)

    Download
Application note SIEMENS
  • Connecting Ethernet coupler 750-342 to a S7-300 (a101400)

    Download
Configuration and Commissioning Software
  • (759-316) WAGO Ethernet Settings / Serie 750

    Download
Firmware
  • 0750-0342, Feldbuskoppler ETHERNET

    Download
CAD data
  • 2D/3D Models 750-342

    Download
CAE data
  • EPLAN Data Portal 750-342

    Download
  • WSCAD Universe 750-342

    Download
  • ZUKEN Portal 750-342

    Download
Device Driver
  • WAGO USB Service Kabel Treiber / Serie 750 und 857

    Download
Compliance Search
  • Environmental Product Compliance 750-342

    Download