750-484/040-000 - 2-channel analog input; 4 … 20 mA HART; Intrinsically safe; Extreme

  • Brand: Wago
  • Product Code: 750-484/040-000
Description: This analog input module connects two field-side signal conditioners equipped with a HART interface that are to be used in hazardous areas of Zone 0+1. The module supplies signal conditioners, reads process values via analog interface, and enables HART communication for configuring and importing dynamic variables. The WAGO I/O System 750 XTR must be installed either in Zone 2 or in a non-hazardous area. The 24 V supply is supplied to the field contacts (HART +) from the power jumper contacts via multipliers. The shield directly connects to the DIN-rail. The measurement input is equipped with current limitation, which limits the current to 25 mA. This module powers 2-wire signal conditioners without dedicated power supply. Up to 4 HART dynamic variables (PV, SV, TV, QV) per channel can be mapped in the cyclic process image of the coupler or controller (parameterizable). For HART communication with connected intelligent HART field devices, the HART protocol can be mapped in the cyclic process image of the coupler or controller (parameterizable). FDT/DTM device drivers are available for select (programmable) couplers, allowing HART tool routing to the connected HART device. The device is ideal for operation in extreme environments thanks to: An extended temperature range Greater immunity to impulse voltages and electromagnetic interference Higher vibration and shock resistance
Description: This analog input module connects two field-side signal conditioners equipped with a HART interface that are to be used in hazardous areas of Zone 0+1. The module supplies signal conditioners, reads process values via analog interface, and enables HART communication for configuring and importing dynamic variables. The WAGO I/O System 750 XTR must be installed either in Zone 2 or in a non-hazardous area. The 24 V supply is supplied to the field contacts (HART +) from the power jumper contacts via multipliers. The shield directly connects to the DIN-rail. The measurement input is equipped with current limitation, which limits the current to 25 mA. This module powers 2-wire signal conditioners without dedicated power supply. Up to 4 HART dynamic variables (PV, SV, TV, QV) per channel can be mapped in the cyclic process image of the coupler or controller (parameterizable). For HART communication with connected intelligent HART field devices, the HART protocol can be mapped in the cyclic process image of the coupler or controller (parameterizable). FDT/DTM device drivers are available for select (programmable) couplers, allowing HART tool routing to the connected HART device. The device is ideal for operation in extreme environments thanks to: An extended temperature range Greater immunity to impulse voltages and electromagnetic interference Higher vibration and shock resistance
Notes

Note

The analog output module must only be operated via 24 VDC Ex i XTR power supply (750-606/040-000)!

General information (e.g., installation regulations) on explosion protection is available in the WAGO I/O System 750 XTR manuals!

Technical data

Number of analog inputs

2

Number of Channels

2

Signal type

Current

Signal type (current)

4 … 20 mADC

Supply voltage (sensor)

16.5 VDC; Transmitter supply UV at 20 mA

Sensor connection

2 x (2-wire)

Input filter

parameterizable

Input filter: parametrizable (channel by channel)

yes

Signal characteristics

Single-ended

Diagnostics

Wire break, measurement range overflow

Resolution [bit]

12

Power consumption Pmax.

1.60 W (with slaves (20 mA))

Data width

2 x 2-byte data; 2 x 2-byte data + 2n x 4-byte data (n = number of dynamic variables); 2 x 2-byte data + 6-byte mailbox

Overvoltage protection

30 V, reverse polarity protected

Conversion time (typ. ≤)

10

Measurement error, reference temperature

25

Measurement error, deviation max (upper-range value) ≤±

0.2

Temperature error max. (upper-range value) ≤±

0.01

Intrinsic safety Ex i

yes

Supply voltage (system)

5 VDC; via data contacts

Current consumption (5 V system supply)

25

Supply voltage (field)

24 VDC; (Ex i XTR power supply: UO = max. 26.8 V); via power jumper contacts (power supply via blade contact; transmission via spring contact)

Current consumption, field supply (module with no external load)

26

HART devices per channel

1 device (single-drop, no multi-drop)

HART modems per channel

1 modem (no multiplex)

Power loss Pl

0.62 W (without slaves)

Isolation

300 VAC system/field

Dielectric strength

510 VAC/775 VDC; per EN 60870-2-1

Rated surge voltage

1 kV; Rated surge voltage between intrinsically safe and non-intrinsically safe circuits: 1.5 kV (EN 60079-11)

Number of incoming power jumper contacts

2

Number of outgoing power jumper contacts

2

Current carrying capacity (power jumper contacts)

1

Marking

ATEX/IECEx: II 3 (1) G Ex ec [ia Ga] IIC T4 Gc; II (1) D [Ex ia Da] IIIC; I (M1) [Ex ia Ma] I

Explosion protection

Ex standard

EN/IEC 60079-0, -7, -11

Safety-relevant data (circuit)

Uo = 26.8 V; Io = 90.07 mA; Po = 603.5 mW; Linear characteristic curve

Reactances Ex ia IIC

Lo = 1.8 mH; Co = 0.092 μF

Reactances Ex ia IIB

Lo = 16 mH; Co = 0.72 μF

Reactances Ex ia IIA

Lo = 27 mH; Co = 2.37 μF

Reactances Ex ia I

Lo = 38 mH; Co = 3.85 µF

Reactances (note)

Reactances without accounting for the concurrence of capacitance (Co) and inductance (Lo)

Connection data

Connection technology: inputs / outputs

16 x CAGE CLAMP®

Connection type 1

Inputs/Outputs

Solid conductor

0.25 … 2.5 mm² / 24 … 14 AWG

Fine-stranded conductor

0.25 … 2.5 mm² / 24 … 14 AWG

Strip length

8 … 9 mm / 0.31 … 0.35 inches

Physical data

Width

24 mm / 0.945 inches

Height

100 mm / 3.937 inches

Depth

67.8 mm / 2.669 inches

Depth from upper-edge of DIN-rail

60.6 mm / 2.386 inches

Mechanical data

Mounting type

DIN-35 rail

Material data

Color

blue

Housing material

Polycarbonate; polyamide 6.6

Fire load

1.248

Weight

92.9

Conformity marking

CE

Environmental requirements

Ambient temperature (operation)

-40 … +70 °C

Surrounding air temperature (storage)

-40 … +85 °C

Protection type

IP20

Pollution degree (5)

2 per IEC 61131-2

Operating altitude

without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)

Mounting position

horizontal (standing/lying); vertical

Relative humidity (without condensation)

95

Relative humidity (with condensation)

Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)

Vibration resistance

per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3

Shock resistance

per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 61373

EMC immunity to interference

per EN 61000-6-1, -2, EN 61131-2, marine applications, EN 60255-26, EN 60870-2-1, EN 61850-3, IEC 61000-6-5, IEEE 1613, VDEW: 1994

EMC emission of interference

per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3

Exposure to pollutants

Per IEC 60068-2-42 and IEC 60068-2-43

Permissible pollutant concentration H2S at a relative humidity < 75%

10

Permissible pollutant concentration SO 2 at a relative humidity < 75%

25

Data sheet
  • 750-484/040-000, 2AI 4-20mA HART Ex i XTR

    Download
Manual
  • System Manual XTR

    Download
  • 2-channel, 4-20mA, HART, Ex i, single ended /XTR

    Download
Bid Text
  • 750-484/040-000

    Download
  • 750-484/040-000

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
System Description
  • Overview on WAGO-I/O-SYSTEM 750 approvals

    Download
  • Intrinsically Safe XTR Modules ‒ General Product Information

    Download
Application Note CoDeSys 2.3
  • HART Tool Routing via PROFIBUS with 750-833 and 750-333 (a116140)

    Download
  • HART Tool Routing via ETHERNET with
    750-820x/750-88x and CODESYS 2.3 (a116120)

    Download
Application Note e!COCKPIT
  • HART Tool Routing via ETHERNET with 750-820x and e!RUNTIME (a116130)

    Download
CAD data
  • 2D/3D Models 750-484/040-000

    Download
CAE data
  • EPLAN Data Portal 750-484/040-000

    Download
  • ZUKEN Portal 750-484/040-000

    Download
  • EPLAN Data Portal 750-484/040-000

    Download