Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

750-495/040-010 - 3-Phase Power Measurement; 20 kVAC 300 A; Extreme

  • Brand: Wago
  • Product Code: 750-495/040-010
Description: The 750-495/040-010 3-Phase Power Measurement Module (also referred to as I/O module) measures the electrical data of a 3-phase supply network in the medium voltage range up to 20 kVrms using voltage sensors per IEC 60044-7 (new IEC 61869-11) and current sensors per IEC 60044-8 (new IEC 61869-10). This I/O module measures rated voltages up to ULL = 20 kVrms (ULN = 11.547 kVrms) and rated currents up to 300 ARMS. The module provides a large number of measured quantities, allowing comprehensive analysis of the 3-phase network. These metrics enable the operator to optimize supply to their systems, protecting them from damage and failure. The voltages of the three phases are connected via voltage sensors to terminals L1, L2, L3 and N, the currents via current sensors to terminals I1, I2, I3 and N. Based on these input signals, the I/O module determines various AC measured variables, such as voltage and current, reactive, apparent and active power, energy consumption, power factor, phase angle and frequency. Harmonic analysis (current/voltage) is also possible for a selectable phase up to the 41st harmonic. The variables are available in the process image, without requiring high processing power from the controller. The device is ideal for operation in extreme environments thanks to: An extended temperature range Greater immunity to impulse voltages and electromagnetic interference Higher vibration and shock resistance
Description: The 750-495/040-010 3-Phase Power Measurement Module (also referred to as I/O module) measures the electrical data of a 3-phase supply network in the medium voltage range up to 20 kVrms using voltage sensors per IEC 60044-7 (new IEC 61869-11) and current sensors per IEC 60044-8 (new IEC 61869-10). This I/O module measures rated voltages up to ULL = 20 kVrms (ULN = 11.547 kVrms) and rated currents up to 300 ARMS. The module provides a large number of measured quantities, allowing comprehensive analysis of the 3-phase network. These metrics enable the operator to optimize supply to their systems, protecting them from damage and failure. The voltages of the three phases are connected via voltage sensors to terminals L1, L2, L3 and N, the currents via current sensors to terminals I1, I2, I3 and N. Based on these input signals, the I/O module determines various AC measured variables, such as voltage and current, reactive, apparent and active power, energy consumption, power factor, phase angle and frequency. Harmonic analysis (current/voltage) is also possible for a selectable phase up to the 41st harmonic. The variables are available in the process image, without requiring high processing power from the controller. The device is ideal for operation in extreme environments thanks to: An extended temperature range Greater immunity to impulse voltages and electromagnetic interference Higher vibration and shock resistance
  • Available Quantity: 0

$990.10

Technical data

Number of measurement inputs

6 (3 input pairs for voltage and current measurement sensors)

Signal type

Power measurement

Signal form

Any periodic signals (considering the threshold frequencies)

Resolution [bit]

24

Data width

2 x 128-bit data; 2 x 64-bit control/status

Voltage path input resistance (typ.)

200.3

Current path input resistance (typ.)

20.8 Ω

Reference for measurement error

AC current/voltage

Measurement error, deviation max (upper-range value) ≤±

0.3

Frequency range (mains frequency)

45 … 65 Hz

Frequency range (harmonics analysis)

45 … 2665 Hz

Limit frequency

8.6

Calculated values

Line-to-line voltage, power output, energy, power factors, mains frequency, harmonic analysis (up to the 41st harmonic), THD

Measurement method

True RMS measurement

Supply voltage (system)

5 VDC; via data contacts

Current consumption (5 V system supply)

100

Rated surge voltage

4 kV

Overvoltage category

III (EN 61010)

Connection data

Connection technology: inputs / outputs

16 x CAGE CLAMP®

Connection type 1

Inputs/outputs

Solid conductor

0.25 … 2.5 mm² / 24 … 14 AWG

Fine-stranded conductor

0.25 … 2.5 mm² / 24 … 14 AWG

Strip length

8 … 9 mm / 0.31 … 0.35 inches

Physical data

Width

24 mm / 0.945 inches

Height

100 mm / 3.937 inches

Depth

67.8 mm / 2.669 inches

Depth from upper-edge of DIN-rail

60.6 mm / 2.386 inches

Mechanical data

Mounting type

DIN-35 rail

Material data

Housing material

Polycarbonate; polyamide 6.6

Fire load

0.273

Weight

99.4

Conformity marking

CE

Environmental requirements

Ambient temperature (operation)

-40 … +70 °C

Surrounding air temperature (storage)

-40 … +85 °C

Protection type

IP20

Operating altitude

without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)

Mounting position

horizontal (standing/lying); vertical

Relative humidity (without condensation)

95

Relative humidity (with condensation)

Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)

Vibration resistance

per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373

Shock resistance

per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 50155, EN 61373

EMC immunity to interference

Per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26;
EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994

EMC emission of interference

per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5

Exposure to pollutants

per IEC 60068-2-42 and IEC 60068-2-43

Permissible pollutant concentration H2S at a relative humidity < 75%

10

Permissible pollutant concentration SO 2 at a relative humidity < 75%

25

Manual
  • System Manual XTR

    Download
  • 3-Phase Power Measurement; 20 kVAC 300 A; Extreme

    Download
System Description
  • 750 XTR Series I/O-System ‒ General Product Information

    Download
  • Overview on WAGO-I/O-SYSTEM 750 approvals

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
Library
  • PowerMeasurement_495_040_010.lib

    Download
Compliance Search
  • Environmental Product Compliance 750-495/040-010

    Download