Description: The 750-498 I/O Module measures either voltages (mV) in the field or analyzes thermocouples. Depending on the sensor selection for the respective I/O module, the voltage value is output directly or converted into the respective temperature value. Based on the measured values supplied by the thermocouple and the cold junction temperature, the I/O module determines the corresponding temperature at the measurement point of the thermocouple used. The I/O module has eight input channels, providing a direct connection from thermocouples to 2-wire sensors. The field level and the system level are electrically isolated from one another.
Description: The 750-498 I/O Module measures either voltages (mV) in the field or analyzes thermocouples. Depending on the sensor selection for the respective I/O module, the voltage value is output directly or converted into the respective temperature value. Based on the measured values supplied by the thermocouple and the cold junction temperature, the I/O module determines the corresponding temperature at the measurement point of the thermocouple used. The I/O module has eight input channels, providing a direct connection from thermocouples to 2-wire sensors. The field level and the system level are electrically isolated from one another.
  • Available Quantity: 0

$711.10

Technical data

Number of analog inputs

8

Number of Channels

8

Signal type

Thermocouple

Low voltages

Signal type (configurable)

Yes

Sensor connection

8 x (2-wire)

Data width

8 x 16-bit data; 8 x 8-bit control/status (optional)

Resolution (over entire range)

0.1 °C

Conversion time

≤100 ms (per channel), activated notch filter; ≤50 ms (per channel), deactivated notch filter

Measurement error (25 °C)

with cold junction compensation: ≤ ±1 K (type E, N, K, T, J) at ≥-50 °C; ≤ ±2 K (type S, R, C) at ≥100 °C; ≤ ±3 K (type B) at ≥350 °C;(Please find additional measurement error information in the manual.)

Temperature error max. (upper-range value) ≤±

0.05

Temperature coefficient

Type K: ±0.05 K/K of the upper-range value; Voltage measurements: ±50 ppm/K of the upper-range value

Sensor types

Type K, J, B, E, N, R, S, T, C; Voltage measurement: ±30 mV; ±60 mV; ±120 mV; ±240 mV

Cold junction compensation

Module-internal based on a cold junction temperature measurement

Configuration options

WAGO-I/O-CHECK

CODESYS Library

e!COCKPIT

Supply voltage (system)

5 VDC; via data contacts

Current consumption (5 V system supply)

100

Supply voltage (field)

24 VDC (-25 … +30 %); via power jumper contacts (power supply via blade contact; transmission via spring contact)

Isolation

500 V system/field

Number of incoming power jumper contacts

2

Number of outgoing power jumper contacts

2

Connection data

Connection technology: inputs / outputs

16 x Push-in CAGE CLAMP®

Connection type 1

Inputs/outputs

Solid conductor

0.08 … 1.5 mm² / 28 … 16 AWG

Fine-stranded conductor

0.25 … 1.5 mm² / 22 … 16 AWG

Strip length

8 … 9 mm / 0.31 … 0.35 inches

Physical data

Width

12 mm / 0.472 inches

Height

100 mm / 3.937 inches

Depth

69 mm / 2.717 inches

Depth from upper-edge of DIN-rail

61.8 mm / 2.433 inches

Mechanical data

Mounting type

DIN-35 rail

Material data

Color

light gray

Housing material

Polycarbonate; polyamide 6.6

Fire load

0.824

Weight

48.9

Conformity marking

CE

Environmental requirements

Ambient temperature (operation)

0 … +55 °C

Surrounding air temperature (storage)

-25 … +85 °C

Protection type

IP20

Pollution degree (5)

2 per IEC 61131-2

Operating altitude

0 … 2000 m / 0 … 6562 ft

Mounting position

horizontal (standing/lying); vertical

Relative humidity (without condensation)

95

Vibration resistance

4g per IEC 60068-2-6

Shock resistance

15g per IEC 60068-2-27

EMC immunity to interference

per EN 61000-6-2, EN 61131-2

EMC emission of interference

per EN 61000-6-3, EN 61131-2

Exposure to pollutants

per IEC 60068-2-42 and IEC 60068-2-43

Permissible pollutant concentration H2S at a relative humidity < 75%

10

Permissible pollutant concentration SO 2 at a relative humidity < 75%

25

Manual
  • System Manual WAGO I/O System 750 / 753

    Download
  • 8-channel, thermocouples

    Download
  • System Manual Series 750/753

    Download
Bid Text
  • 750-498

    Download
  • 750-498

    Download
System Description
  • Use in Hazardous Environments

    Download
  • 750/753 Series I/O-System ‒ General Product Information

    Download
  • Overview on WAGO-I/O-SYSTEM 750 approvals

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
CAE data
  • EPLAN Data Portal 750-498

    Download
CAD data
  • 2D/3D Models 750-498

    Download
Compliance Search
  • Environmental Product Compliance 750-498

    Download