Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

750-586 - 2-channel analog output; 4 … 20 mA; Intrinsically safe

  • Brand: Wago
  • Product Code: 750-586
Description: This analog output module transmits intrinsically safe 4–20 mA signals in Zone 0+1 hazardous areas. The WAGO I/O System 750 must be installed either in Zone 2 or in a non-hazardous area. Power is derived from the power jumper contacts. The outputs are short-circuit-protected. Indicators: Green LED (output status) Field and system levels are electrically isolated.
Description: This analog output module transmits intrinsically safe 4–20 mA signals in Zone 0+1 hazardous areas. The WAGO I/O System 750 must be installed either in Zone 2 or in a non-hazardous area. Power is derived from the power jumper contacts. The outputs are short-circuit-protected. Indicators: Green LED (output status) Field and system levels are electrically isolated.
  • Available Quantity: 0

$1,011.00

Notes

Note

The analog output module must only be operated with a 24 VDC Ex i power supply!

General information (e.g., installation regulations) on explosion protection is available in the WAGO I/O System 750 manuals!

Technical data

Number of analog outputs

2

Number of Channels

2

Signal type

Current

Signal type (current)

4 … 20 mADC

Actuator connection

2 x (2-wire)

Signal characteristics

Single-ended

Resolution [bit]

12

Power consumption Pmax.

1.5 W

Data width

2 x 16-bit data

Load impedance (current output)

≤ 500 Ω

Conversion time (typ. ≤)

2

Measurement error, reference temperature

25

Measurement error, deviation max (upper-range value) ≤±

0.2

Temperature error max. (upper-range value) ≤±

0.01

Output error, deviation (max.) of the upper-range value

0.2

Temperature error (max.) of the output range value

0.01

Intrinsic safety Ex i

yes

Linearity

± 2 LSB

Supply voltage (system)

5 VDC; via data contacts

Current consumption (5 V system supply)

21

Supply voltage (field)

24 VDC; (Ex i power supply: UO = max. 27.3 V); via power jumper contacts (power supply via blade contact; transmission via spring contact)

Current consumption, field supply (module with no external load)

19

Power loss Pl

0.9 W

Isolation

300 VAC system/field

Number of incoming power jumper contacts

2

Number of outgoing power jumper contacts

2

Marking

ATEX/IECEx: II 3 (1) G Ex ec [ia Ga] IIC T4 Gc; II (1) D [Ex ia Da] IIIC; I (M1) [Ex ia Ma] I

Explosion protection

Ex standard

EN IEC 60079-0, -7, -11

Safety-relevant data (circuit)

Uo = 27.3 V; Io = 57.5 mA; Po = 392 mW; Linear characteristic curve

Reactances Ex ia IIC

Lo = 11 mH; Co = 88 nF

Reactances Ex ia IIB

Lo = 56 mH; Co = 680 nF

Reactances Ex ia IIA

Lo = 90 mH; Co = 2.2 μF

Reactances Ex ia I

Lo = 110 mH; Co = 3.5 µF

Reactances (note)

Reactances without accounting for the concurrence of capacitance (Co) and inductance (Lo)

Connection data

Connection technology: inputs / outputs

16 x CAGE CLAMP®

Connection type 1

Inputs/Outputs

Solid conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Fine-stranded conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Strip length

8 … 9 mm / 0.31 … 0.35 inches

Physical data

Width

24 mm / 0.945 inches

Height

100 mm / 3.937 inches

Depth

67.8 mm / 2.669 inches

Depth from upper-edge of DIN-rail

60.6 mm / 2.386 inches

Mechanical data

Mounting type

DIN-35 rail

Material data

Color

blue

Housing material

Polycarbonate; polyamide 6.6

Fire load

1.945

Weight

94.7

Conformity marking

CE

Environmental requirements

Ambient temperature (operation)

0 … +55 °C

Surrounding air temperature (storage)

-25 … +85 °C

Protection type

IP20

Pollution degree (5)

2 per IEC 61131-2

Operating altitude

0 … 2000 m / 0 … 6562 ft

Mounting position

horizontal (standing/lying); vertical

Relative humidity (without condensation)

95

Vibration resistance

4g per IEC 60068-2-6

Shock resistance

15g per IEC 60068-2-27

EMC immunity to interference

per EN 61000-6-2, marine applications

EMC emission of interference

per EN 61000-6-3, marine applications

Exposure to pollutants

Per IEC 60068-2-42 and IEC 60068-2-43

Permissible pollutant concentration H2S at a relative humidity < 75%

10

Permissible pollutant concentration SO 2 at a relative humidity < 75%

25

Data sheet
  • 750-586, 2AO 4-20mA Ex i, data sheet

    Download
Manual
  • System Manual WAGO I/O System 750 / 753

    Download
  • 2-channel, 4 - 20 mA, Ex i

    Download
Bid Text
  • 750-586

    Download
  • 750-586

    Download
System Description
  • Overview on WAGO-I/O-SYSTEM 750 approvals

    Download
  • Ex i Overview

    Download
  • 750/753 Series I/O-System ‒ General Product Information

    Download
  • Use in Hazardous Environments

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
CAD data
  • 2D/3D Models 750-586

    Download
CAE data
  • EPLAN Data Portal 750-586

    Download
  • WSCAD Universe 750-586

    Download
  • ZUKEN Portal 750-586

    Download