Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

750-663/000-003 - Intrinsically safe 4-channel digital input; 24 VDC; PROFIsafe V2.0 iPar

  • Brand: Wago
  • Product Code: 750-663/000-003
Description: The intrinsically safe PROFIsafe Input Module (750-663/000-003) for functional safety provides risk reductions up to SIL 3, Cat. 4, PL e, and connects to potential-free, contact-based emergency stop switches, safety door switches, mode selectors, as well as safety sensors, that are located hazardous environments 0, 1 and 2. The fail-safe input module must be located in Zone 2. The input module features four clock-sensitive inputs (I1 … I4) that are fed by two differently clocked outputs (T1 … T2). Inputs are continually monitored for cross circuits and power supply from separate sources. Additional safety-relevant functions (e.g., operating modes, switching off test pulses, discrepancy or filter times) can be configured via WAGO-I/O-CHECK. This configuration tool supports both CC2 and CC3 tool calling interfaces (TCI). When exchanging the module, parameters are automatically downloaded by the controller via PROFIsafe-compatible iPar server – depending on settings. The module supports both PROFIsafe V1 and V2 (PROFIBUS, PROFINET) protocols. Individual modules can be arranged in any combination within the fieldbus nodes Ex segment. Note 1: The PROFIsafe Input Module must only be operated using an Ex i 24 VDC power supply (e.g., 750-606, 750-625/000-001)! General information (e.g., installation regulations) on explosion protection is available in the WAGO I/O System 750 manuals! Note 2: To protect the module against surge voltages (surge protection per IEC 61000-4-5), a filter module (750-626 or 750-624) or an external surge filter must be used upstream of the Ex i 24 VDC power supply. Reference the product manual for further information!
Description: The intrinsically safe PROFIsafe Input Module (750-663/000-003) for functional safety provides risk reductions up to SIL 3, Cat. 4, PL e, and connects to potential-free, contact-based emergency stop switches, safety door switches, mode selectors, as well as safety sensors, that are located hazardous environments 0, 1 and 2. The fail-safe input module must be located in Zone 2. The input module features four clock-sensitive inputs (I1 … I4) that are fed by two differently clocked outputs (T1 … T2). Inputs are continually monitored for cross circuits and power supply from separate sources. Additional safety-relevant functions (e.g., operating modes, switching off test pulses, discrepancy or filter times) can be configured via WAGO-I/O-CHECK. This configuration tool supports both CC2 and CC3 tool calling interfaces (TCI). When exchanging the module, parameters are automatically downloaded by the controller via PROFIsafe-compatible iPar server – depending on settings. The module supports both PROFIsafe V1 and V2 (PROFIBUS, PROFINET) protocols. Individual modules can be arranged in any combination within the fieldbus nodes Ex segment. Note 1: The PROFIsafe Input Module must only be operated using an Ex i 24 VDC power supply (e.g., 750-606, 750-625/000-001)! General information (e.g., installation regulations) on explosion protection is available in the WAGO I/O System 750 manuals! Note 2: To protect the module against surge voltages (surge protection per IEC 61000-4-5), a filter module (750-626 or 750-624) or an external surge filter must be used upstream of the Ex i 24 VDC power supply. Reference the product manual for further information!
  • Available Quantity: 0

$1,579.00

Technical data

Number of digital inputs

4

Number of Channels

4

Signal type

Voltage

Signal type (voltage)

24 VDC

Sensor connection

4 x (Fail-safe input with test pulse)

Input characteristic

clock sensitive

Input characteristic

Type 1

Input filter (digital)

0.5

1

2

3

5

10

20

50

100

200

0

Input filter

0 … 200 ms (parameterizable in steps)

Input filter: parametrizable (channel by channel)

yes

Input current per channel for signal (1) typ.

3

Output current per channel

0.05

Short-circuit current

≤ 25 mA

Signal frequency (max.)

50

Intrinsic safety Ex i

yes

Configuration options

PROFIsafe address adjustable via DIP switch or engineering software

Supply voltage (system)

5 VDC; via data contacts

Current consumption (5 V system supply)

145

Supply voltage (field)

24 VDC; (Ex i power supply: UO = max. 27.3 V); via power jumper contacts (power supply via blade contact; transmission via spring contact)

Current consumption, field supply (module with no external load)

20

Isolation

300 VAC system/field

Indicators

LED (A-D) green/red: Status/Error I1 … I4; LED (E) red: Group error; LED (F-H) green/red: Diagnostics

Number of incoming power jumper contacts

2

Number of outgoing power jumper contacts

2

Current carrying capacity (power jumper contacts)

1

Marking

ATEX/IECEx: II 3 (1) G Ex ec [ia Ga] IIC T4 Gc; II (1) D [Ex ia Da] IIIC; I (M1) [Ex ia Ma] I

Functional safety

Achievable risk reduction

SIL 3 per IEC 61508; SIL 3 per IEC 61511; SIL 3 per IEC 62061; Cat. 4, PL e per EN ISO 13849

Safety standards

IEC 61508; IEC 62061; EN ISO 13849; IEC 61511

Explosion protection

Ex standard

EN IEC 60079-0, -7, -11

Safety-relevant data (circuit)

Uo = 27.3 V; Io = 23 mA; Po = 157 mW; linear characteristic curve

Reactances Ex ia IIC

Lo = 61 mH; Co = 64 nF

Reactances Ex ia IIB

Lo = 100 mH; Co = 552 nF

Reactances Ex ia IIA

Lo = 100 mH; Co = 2.28 µF

Reactances Ex ia I

Lo = 100 mH; Co = 2.95 µF

Reactances (note)

Reactances without accounting for the concurrence of capacitance (Co) and inductance (Lo)

Connection data

Connection technology: inputs / outputs

8 x CAGE CLAMP®

Connection type 1

Inputs/Outputs

Solid conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Fine-stranded conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Strip length

8 … 9 mm / 0.31 … 0.35 inches

Connection requirement (permissible cable length)

100

Physical data

Width

24 mm / 0.945 inches

Height

100 mm / 3.937 inches

Depth

67.8 mm / 2.669 inches

Depth from upper-edge of DIN-rail

60.6 mm / 2.386 inches

Mechanical data

Mounting type

DIN-35 rail

Material data

Color

multicoloured

Housing material

Polycarbonate; polyamide 6.6

Fire load

1.831

Weight

92

Conformity marking

CE

Environmental requirements

Ambient temperature (operation)

0 … +55 °C

Surrounding air temperature (storage)

-25 … +85 °C

Protection type

IP20

Pollution degree (5)

2 per IEC 61131-2

Operating altitude

0 … 2000 m / 0 … 6562 ft

Mounting position

horizontal (standing/lying); vertical

Relative humidity (without condensation)

95

Vibration resistance

4g per IEC 60068-2-6

Shock resistance

15g per IEC 60068-2-27

EMC immunity to interference

per EN 61000-6-2, marine applications

EMC emission of interference

per EN 61000-6-3, marine applications

Exposure to pollutants

Per IEC 60068-2-42 and IEC 60068-2-43

Permissible pollutant concentration H2S at a relative humidity < 75%

10

Permissible pollutant concentration SO 2 at a relative humidity < 75%

25

Data sheet
  • 750-663/000-003, 4F Ex i DI 24V PROFIsafe V2 iPar, data sheet

    Download
Manual
  • System Manual WAGO I/O System 750 / 753

    Download
  • 4-channel, Ex i, 24 V, PROFIsafe V2 iPar

    Download
  • System Manual Series 750/753

    Download
Bid Text
  • 750-663/000-003

    Download
  • 750-663/000-003

    Download
Instruction Leaflet
  • Gebrauchs- und Montageanleitung

    Download
System Description
  • Ex i Overview

    Download
  • Use in Hazardous Environments

    Download
  • Functional Safety ‒ General Product Information

    Download
  • Overview on WAGO-I/O-SYSTEM 750 approvals

    Download
  • 750/753 Series I/O-System ‒ General Product Information

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
SISTEMA library
  • VDMA-Bibliothek

    Download
  • SISTEMA-Bibliothek

    Download
Library
    Configuration and Commissioning Software
    • Safety Editor (SEDI) / 750-66x

      Download
    CAD data
    • 2D/3D Models 750-663/000-003

      Download
    CAE data
    • EPLAN Data Portal 750-663/000-003

      Download
    • WSCAD Universe 750-663/000-003

      Download
    • ZUKEN Portal 750-663/000-003

      Download
    • EPLAN Data Portal 750-663/000-003

      Download
    • WSCAD Universe 750-663/000-003

      Download