Description: In conjunction with the WAGO I/O System, the ETHERNET Controller serves ETHERNET networks requiring fast and safe media redundancy. The controller supports all digital, analog and specialty modules found within the 750/753 Series, and is suitable for data rates of 10/100 Mbit/s. Media redundancy is achieved by operating the controller in two separate networks – which is accessible via two different IP addresses (including two MAC IDs). Cross communication between separate channels is not possible. The two separate ETHERNET interfaces allow redundant connection of two transmission paths (no hub or switch required). Both interfaces support autonegotiation and Auto-MDI(X). The DIP switch configures the last byte of both default IP addresses and may be used for IP address assignment (DHCP, BootP). The media redundancy controller is designed for fieldbus communication via MODBUS/TCP in ETHERNET networks. It also supports a wide variety of standard ETHERNET protocols (HTTP, BootP, DHCP, DNS, FTP). An integrated Webserver provides user configuration options, while displaying the controllers status information. The IEC 61131-3 programmable controller is multitasking-capable and features a capacitor-backed RTC. A data memory of 1 MB is available. For memory expansion, the 750-885 Controller is equipped with a removable memory card slot.
Description: In conjunction with the WAGO I/O System, the ETHERNET Controller serves ETHERNET networks requiring fast and safe media redundancy. The controller supports all digital, analog and specialty modules found within the 750/753 Series, and is suitable for data rates of 10/100 Mbit/s. Media redundancy is achieved by operating the controller in two separate networks – which is accessible via two different IP addresses (including two MAC IDs). Cross communication between separate channels is not possible. The two separate ETHERNET interfaces allow redundant connection of two transmission paths (no hub or switch required). Both interfaces support autonegotiation and Auto-MDI(X). The DIP switch configures the last byte of both default IP addresses and may be used for IP address assignment (DHCP, BootP). The media redundancy controller is designed for fieldbus communication via MODBUS/TCP in ETHERNET networks. It also supports a wide variety of standard ETHERNET protocols (HTTP, BootP, DHCP, DNS, FTP). An integrated Webserver provides user configuration options, while displaying the controllers status information. The IEC 61131-3 programmable controller is multitasking-capable and features a capacitor-backed RTC. A data memory of 1 MB is available. For memory expansion, the 750-885 Controller is equipped with a removable memory card slot.
  • Available Quantity: 0

$1,316.00

Technical data

Communication

EtherNet/IP

Modbus (TCP, UDP)

ETHERNET

ETHERNET protocols

HTTP

BootP

DHCP

DNS

SNTP

FTP

SNMP

Redundancy function

via two logically separated ETHERNET interfaces

Visualization

Web-Visu

Web Visu

CPU

32 bits

Programming languages per IEC 61131-3

Instruction List (IL)

Ladder Diagram (LD)

Function Block Diagram (FBD), Continuous Function Chart (CFC)

Structured Text (ST)

Sequential Function Chart (SFC)

Programming environment

WAGO-I/O-PRO V2.3 (based on CODESYS V2.3)

Configuration options

WAGO-I/O-CHECK

Web-Based Management

Baud rate (communication/fieldbus 1)

10/100 Mbit/s

Baud rate

10/100 Mbit/s

Transmission medium (communication/fieldbus)

Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length

Transmission performance

Class D per EN 50173

Program memory

1024 KB

Data memory

1024 KB

Non-volatile software memory

32

Type of memory card

SD card

Memory card slot

Push-push mechanism; Cover lid (sealable)

Number of modules per node (max.)

250

Number of modules without a bus extension (max.)

64

Input and output process image (fieldbus) max.

1020 Worte/1020 Worte

Indicators

LED (LINK/ACT) green: Network connection via ports 1 … 2; LED (MS, NS) red/green: Status of node, network; LED (I/O, USR) red/green/orange: Local data bus status, status programmable by user; LED (A, B) green: System power supply status, field supply

Supply voltage (system)

24 VDC (-25 … +30 %); via pluggable connector (CAGE CLAMP® connection)

Input current (typ.) at nominal load (24 V)

500

Power supply efficiency (typ.) at nominal load (24 V)

90

Current consumption (5 V system supply)

450

Total current (system supply)

1,700

Supply voltage (field)

24 VDC (-25 … +30 %); via power jumper contacts

Current carrying capacity (power jumper contacts)

10

Number of outgoing power jumper contacts

3

Isolation

500 V system/field

Connection data

Connection technology: communication/fieldbus

EtherNet/IPTM: 2 x RJ-45; Modbus TCP/UDP: 2 x RJ-45

Connection technology: system supply

2 x CAGE CLAMP®

Connection technology: field supply

6 x CAGE CLAMP®

Connection type 1

System/field supply

Solid conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Fine-stranded conductor

0.08 … 2.5 mm² / 28 … 14 AWG

Strip length

8 … 9 mm / 0.31 … 0.35 inches

Connection technology: device configuration

1 x Male connector; 4-pole

Physical data

Width

61.5 mm / 2.421 inches

Height

100 mm / 3.937 inches

Depth

71.9 mm / 2.831 inches

Depth from upper-edge of DIN-rail

64.7 mm / 2.547 inches

Mechanical data

Weight

161.9

Color

light gray

Housing material

Polycarbonate; polyamide 6.6

Conformity marking

CE

Environmental requirements

Ambient temperature (operation)

0 … +55 °C

Surrounding air temperature (storage)

-25 … +85 °C

Protection type

IP20

Pollution degree (5)

2 per IEC 61131-2

Operating altitude

without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.)

Relative humidity (without condensation)

95

Mounting position

any

Mounting type

DIN-35 rail

Vibration resistance

4g per IEC 60068-2-6

Shock resistance

15g per IEC 60068-2-27

EMC immunity to interference

per EN 61000-6-2, marine applications

EMC emission of interference

per EN 61000-6-3, marine applications

Exposure to pollutants

Per IEC 60068-2-42 and IEC 60068-2-43

Fire load

3.588

Permissible pollutant concentration H2S at a relative humidity < 75%

10

Permissible pollutant concentration SO 2 at a relative humidity < 75%

25

Manual
  • System Manual WAGO I/O System 750 / 753

    Download
  • WAGO MODBUS Master Configurator

    Download
  • ETHERNET-MR/SD-Fieldbus Controller

    Download
  • System Manual Series 750/753

    Download
Bid Text
  • 750-885

    Download
  • 750-885

    Download
System Description
  • 750 Controller, General Product Information

    Download
  • Overview on WAGO-I/O-SYSTEM 750 approvals

    Download
  • Use in Hazardous Environments

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
Application Note CoDeSys 2.3
  • Application Note: MpBus_03 Library

    Download
  • Connection of Thermokon Multi-function room control units WRF 08

    Download
  • Connection of Thermokon Multi-function room control units WRF 06

    Download
  • HART Tool Routing via ETHERNET with
    750-820x/750-88x and CODESYS 2.3 (a116120)

    Download
  • HVAC System Macros

    Download
  • Using the web visualization with Java™ runtime environment (JRE, JVM) 7 update 51 (7u51) (a500690)

    Download
  • Anbindung der HKW-Elektronik Wetterprognose-Station WS-K xx T ModBus

    Download
  • Application Note: DMX_02

    Download
  • GRUNDFOS GENIbus interface, application note

    Download
  • Application Note: EnOcean_06 Library

    Download
  • Application Note Library ModuleAccess_01

    Download
  • HLK-Anlagenmakros für TRIC

    Download
  • Application Note for the 750-494 3-Phase Power Measurement Module

    Download
  • Application Note for the 750-495 3-Phase Power Measurement Module

    Download
  • Connection of a Thermokon Thanos SR L MODBUS room control unit to the WAGO-I/O-SYSTEM

    Download
  • Connection of DMX devices to the WAGO-I/O-SYSTEM via the ArtNet-DMX STAGE-PROFI 1.1

    Download
  • Application Note PowerMeasurement_03 Library

    Download
  • Application Note DaylightSaving

    Download
  • Application Note Connecting with an iPod Touch

    Download
  • Application Note Weather Station Elsner P03 Modbus

    Download
  • Application Note Scheduler_03.lib

    Download
Library
  • ModuleAccess_01.lib

    Download
  • WagoLibConfigETH_01

    Download
Configuration and Commissioning Software
  • WAGO-IO-PRO Demo-Version (759-912) / Serie 750, 758 und 762

    Download
  • WAGOupload

    Download
  • (759-316) WAGO Ethernet Settings / Serie 750

    Download
Firmware
  • 0750-0885, Controller ETHERNET

    Download
CAE data
  • WSCAD Universe 750-885

    Download
  • ZUKEN Portal 750-885

    Download
  • EPLAN Data Portal 750-885

    Download
CAD data
  • 2D/3D Models 750-885

    Download
Compliance Search
  • Environmental Product Compliance 750-885

    Download