Technical data
Control circuit

Nominal input voltage UN

DC 24 V

Input voltage range

±10 %

Nominal input current at UN

16.7 mA

Load circuit

Number of changeover contacts

1

Contact material (relay)

AgNi

Limiting continuous current

16 A

Inrush current (resistive) max.

(AC) 32 A / 0.02 s; (AC) 24 A / 4 s

Switching voltage (max.)

AC 250 V

Switching power (resistive) max.

AC 4000 VA; DC (see load limit curve)

Switching capacity

AC-15: 3 A / AC 240 V; DC-13: 2 A / DC 24 V

Recommended minimum load

12 V / 10 mA

Pull-in time (typ.)

15

Drop-out time (typ.)

8

Bounce time (typ.)

6

Electrical life (NO; resistive load; 23 °C)

10 x 103 switching operations

Mechanical life

5 x 106 switching operations

Switching frequency with/without load (max.)

6 min-1 / 300 min-1

Signaling

Status indicator

Red LED

Mechanical

Safety and protection

Rated voltage

250

Rated surge voltage

4

Pollution degree

3

Dielectric strength (control/load circuit) (AC, 1 min)

5 kVrms

Dielectric strength (open contact) (AC, 1 min)

1 kVrms

Safety information 1

A separator plate (e.g., 209-191) must be used for voltages greater than 250 V between adjacent relay modules and for compliance with the reinforced insulation requirements.

Protection type

IP20

Notes

Safety information 1

A separator plate (e.g., 209-191) must be used for voltages greater than 250 V between adjacent relay modules and for compliance with the reinforced insulation requirements.

Note

  • Reinforced insulation between coil and contacts
  • To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.

Connection data

Connection technology

Push-in CAGE CLAMP®

Solid conductor

0.34 … 2.5 mm² / 22 … 14 AWG

Fine-stranded conductor

0.34 … 2.5 mm² / 22 … 14 AWG

Strip length

9 … 10 mm / 0.35 … 0.39 inch

Physical data

Width

15 mm / 0.591 inch

Height

86 mm / 3.386 inch

Depth from upper-edge of DIN-rail

73 mm / 2.874 inch

Mechanical data

Mounting type

DIN-35 rail

Material data

Fire load

0.689

Weight

55.2

Environmental requirements

Ambient temperature (operation at UN)

-40 … 70 °C

Ambient temperature UL (operation at UN)

-40 … 50 °C

Surrounding air temperature (storage)

-40 … +70 °C

Processing temperature

-25 … +50 °C

Standards and specifications

Standards/specifications

EN 61010-2-201

EN 61810-1

EN 61373

UL 508 (max. 10 A)

Basic relay

WAGO Basic Relay

788-931

Bid Text
  • 788-341

    Download
  • 788-341

    Download
Instruction Leaflet
  • Sockets with Elementary Relay/ SSR

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
CAD data
  • 2D/3D Models 788-341

    Download
CAE data
  • EPLAN Data Portal 788-341

    Download
  • WSCAD Universe 788-341

    Download
  • ZUKEN Portal 788-341

    Download
Compliance Search
  • Environmental Product Compliance 788-341

    Download