K2A6C30EP56BR - Intrepid Series EP56 Outdoor
- Brand: Kooltronic
- Product Code: K2A6C30EP56BR
- The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
- A speed control sensing bulb located in the condenser air outlet area switches the condenser blower between minimum and maximum speed based on the ambient temperature. This reduces noise levels, fan cycling, compressor cycling and prevents the unit from freezing.
- 120V or 240V heater attached to the compressor crankcase to maintain appropriate temperatures during cold operating conditions.
- Electronic Thermostatic Low Temperature Control prevents over-cooling and provides energy-efficient operation.
- Fully gasketed for tight, leakproof installation, in compliance with the NEMA 12, 3R & 1 Enclosure Ratings.
- R410a, an HFC having zero ozone depleting potential.
- Eliminates damaging condensation, increasing reliability of electrical enclosure components.
- This protection increases reliability in hostile environments. This protection for the refrigeration system consists of an air cured coating applied to the brazed joints on the condenser side, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or GuardianX Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
- Used only with a user-installed remote thermostat or the Kooltronic KLLC100 Lead Lag Controller, this 24VAC relay can be used for the sequential operation of two units or with a single unit. An external terminal strip is provided for field interconnection. NOTE: User-installed thermostat must have a set point of 75°F with a differential of 11°F. NOTE: A factory installed thermostat is not provided with this option.
- A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.
Air Conditioner Quick-Sheet [105Kb]
Condensate Evaporator Kits [241Kb]
Condensation and Electronics [3983Kb]
Electronic Enclosure Cooling With Special Purpose Air Conditioners [254Kb]
Hazardous Location Series White Paper [234Kb]
Increasing the Lifespan and Reliability of Electrical Components [212Kb]
Slimkool Series Flyer [584Kb]
Kooltronic Custom Capabilities Flyer [2194Kb]
Kooltronic Custom Cooling Medical Flyer [211Kb]
Kooltronic Design Guide/Catalog (220 pages) [229400Kb]
Kooltronic Refrigeration System Manufacturing [55Kb]
Kooltronic Standard Warranty [55Kb]
Kooltronic Unit Longevity Press Release [167Kb]
NEMA Enclosure Ratings [91Kb]
Short-Form Catalog (16 pages) [897Kb]
Airflow Switch Data Sheet [159Kb]
Laboratory Environmental Testing Services [157Kb]
Powder Paint Application Facilities Flyer [165Kb]
K2A6C30EP56_R Wiring Diagram (Ladder) [53Kb]
K2A6C30EP56_R Wiring Diagram (Point-to-Point) [64Kb]
K2A6C30EP56_R Wiring Diagram (Point-to-Point) [62Kb]
K2A6C30EP56_R Wiring Diagram (Point-to-Point) [66Kb]
K2A6C30EP56_R Wiring Diagram (Point-to-Point) [64Kb]
K2A6C30EP56BR-2,-3 Wiring Diagram (Point-to-Point) [75Kb]
K2A6C30EP56TR-4 Wiring Diagram (Point-to-Point) [85Kb]