KPHE28 - KPHE28 Water-to-Air

Description: Description KOOLTRONIC Water-to-Air Heat Exchangers provide uniform cooling in a closed-loop system where a reliable source of clean, cool water is available. The KPHE Series is designed primarily for use in harsh environments with cooling requirements in excess of the capabilities of Air-to-Air Heat Exchangers. They are particularly useful in highly contaminated environments that would require very frequent cleaning or changing of ambient air filters, or require frequent cleaning of the heat exchanger core. KOOLTRONIC Water-to-Air Heat Exchangers can furnish greater cooling capacities than air-to-air models, depending on water temperature and rate of flow. Ambient air is sealed out; heat transfer surfaces remain clean. The higher cooling ability of the KPHE Series depends on the temperature of the cooling water. Thus, if the water is cold enough, the temperature of the air delivered to the electronics cabinet can actually be lower than that provided by air conditioners, at less cost. KPHE Series Heat Exchangers are available in five sizes and capacities. All models are UL/CUL Listed and meet NEMA 12 and NEMA 3R requirements. A complete range of accessories and options is available for both units, adding to their versatility. KOOLTRONIC also designs and manufactures a variety of heat exchangers to meet unique specifications. We invite your inquiries about our modification and custom-design capabilities.
Description: Description KOOLTRONIC Water-to-Air Heat Exchangers provide uniform cooling in a closed-loop system where a reliable source of clean, cool water is available. The KPHE Series is designed primarily for use in harsh environments with cooling requirements in excess of the capabilities of Air-to-Air Heat Exchangers. They are particularly useful in highly contaminated environments that would require very frequent cleaning or changing of ambient air filters, or require frequent cleaning of the heat exchanger core. KOOLTRONIC Water-to-Air Heat Exchangers can furnish greater cooling capacities than air-to-air models, depending on water temperature and rate of flow. Ambient air is sealed out; heat transfer surfaces remain clean. The higher cooling ability of the KPHE Series depends on the temperature of the cooling water. Thus, if the water is cold enough, the temperature of the air delivered to the electronics cabinet can actually be lower than that provided by air conditioners, at less cost. KPHE Series Heat Exchangers are available in five sizes and capacities. All models are UL/CUL Listed and meet NEMA 12 and NEMA 3R requirements. A complete range of accessories and options is available for both units, adding to their versatility. KOOLTRONIC also designs and manufactures a variety of heat exchangers to meet unique specifications. We invite your inquiries about our modification and custom-design capabilities.
Data
Closed-Loop Cooling
  • The enclosure interior airflow system is isolated from the ambient airflow or waterflow system. No ambient air can invade the cool, dehumidified sensitive component compartment.
Epoxy-Coated Heat Exchanger Coils
  • Heat Exchanger Coils are epoxy-coated. This coating will withstand 1000 hours of salt spray per the ASTM B 117 test method. Also see Stainless Steel Cabinet or Integrity NEMA 4/4X Air Conditioners. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosion protection options, contact factory.
NEMA 12 & 3R Ratings Maintained (UL50)
  • All units are fully gasketed for tight, leakproof installation, in compliance with the NEMA 12 and 3R Enclosure Ratings.
UL/CSA Ball-Bearing Motors
  • All motors, whether permanent split capacitor or shaded pole, are UL/CSA Recognized and include automatic-reset thermal overload protection. Designed for low temperature rise, Kooltronic motors are also cooled by the blowers' intake air, for maximum motor life. All motors are UL Recognized and carry a Declaration of Conformity to applicable CE Standards. Special permanent lubricants perform over a broad temperature range: -20°F (-29°C) to 250°F (121°C).
Automatic Water Flow Control
  • This control consists of a temperature control thermostat and a solenoid valve. When the temperature within the enclosure drops below the thermostat set point due to decreased load or decreasing water temperature, the thermostat closes the solenoid valve. When the temperature increases to the set point (plus a differential) the thermostat opens the solenoid valve and the supply water cools the enclosure. In most models the Automatic Water Flow Control also includes a bypass flow meter which allows a small amount of water (0.25 gpm) to pass through the heat exchanger at all times.
High Water Level Detector
  • Closes water-supply valve to prevent flooding if excess water accumulates in the drain pan. Signal circuit activates a user-supplied warning device. The low voltage power for the signal circuit is supplied by the user.
Internal Corrosion Protection - KPHE Series
  • This protection increases reliability in hostile environments. This protection for the cooling system consists of an air cured coating applied to the brazed joints, providing a degree of protection from corrosive environments. This coating will withstand 1000 hours of salt spray per ASTM B 117 test method. Also see KNHE Series NEMA 4X Stainless Steel Heat Exchangers. NOTE: Severe operational environments such as waste water treatment and salt spray are likely to cause corrosion failure over a period of time regardless of coating. This coating provides protection to the external portion of the coil and does not protect from any corrosive elements in the cooling water used internally. Warranty: Corrosive conditions may affect the warranty coverage. Consult factory for warranty limitations in corrosive environments. NOTE: For additional corrosive protection options, contact factory.
Low Airflow Detector
  • Similar to the Airflow Switch shown in the Blower Accessories Section, the switch is installed in a suitable location in the air conditioner to detect loss of airflow, and sends a signal to a terminal block, through which user-installed wiring and warning devices are activated.
Temperature Alarm
  • A thermostat is mounted inside the cabinet and attached to a sensor in the warm air return. When the air temperature increases to the set point, a signal is sent to a terminal block. User-installed wiring from the terminal block to local and/or remote warning devices (light, bell, siren, etc.) can be for normally open or closed operation.
Data Sheet
  • KPHE28 Product Data Sheet [76Kb]

    Download
GA Drawing
  • KPHE28 General Arrangement Drawing [55Kb]

    Download
Installation Instructions
  • KPHE28 Installation Instructions (2 pages) [125Kb]

    Download
Literature
  • Condensate Evaporator Kits [241Kb]

    Download
  • Increasing the Lifespan and Reliability of Electrical Components [212Kb]

    Download
  • Kooltronic Custom Capabilities Flyer [2194Kb]

    Download
  • Kooltronic Custom Cooling Medical Flyer [211Kb]

    Download
  • Kooltronic Design Guide/Catalog (220 pages) [229400Kb]

    Download
  • Kooltronic Refrigeration System Manufacturing [55Kb]

    Download
  • Kooltronic Standard Warranty [55Kb]

    Download
  • Kooltronic Unit Longevity Press Release [167Kb]

    Download
  • NEMA Enclosure Ratings [91Kb]

    Download
  • Short-Form Catalog (16 pages) [897Kb]

    Download
  • Airflow Switch Data Sheet [159Kb]

    Download
  • Heat Exchanger Quick-Sheet [90Kb]

    Download
  • Laboratory Environmental Testing Services [157Kb]

    Download
  • Powder Paint Application Facilities Flyer [165Kb]

    Download
Operator's Manual
  • KLLC100 Lead-Lag Controller [38Kb]

    Download
  • KLLC480 Lead-Lag Controller [79Kb]

    Download
  • KPHE28 Operator's Manual [92Kb]

    Download
Wiring Diagram
  • K_PHE28 Wiring Diagram [34Kb]

    Download
  • KPHE28CDMW Wiring Diagram [57Kb]

    Download