Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

101147091 - BN 325-R-1279

Description:
Productfeatures
  • Cable output left and 2 shielding plates
  • Actuation from front
  • Non-contact principle
  • 1 Reed contakts
  • Long life
  • Actuating surface and direction of actuation marked by switch symbol
  • 85 mm x 26 mm x 24 mm
  • Thermoplastic enclosure
  • Spade connector
Data
Ordering data

Product type description

BN 325-R-1279

Article number (order number)

101147091

EAN (European Article Number)

4030661141299

eCl@ss number, version 9.0

27-27-01-05

eCl@ss number, version 11.0

27-27-01-05

ETIM number, version 7.0

EC002544

ETIM number, version 6.0

EC002544

General data

Working principle

Magnetic drive

Housing construction form

rectangular

Enclosure material

Glass-fibre, reinforced thermoplastic

Gross weight

98 g

General data - Features

Latching

Yes

Suitable for elevators

Yes

Number of snap-in contacts

1

Mechanical data

Actuating panels

front side

Actuating element

Magnet

Mechanical life, minimum

1,000,000,000 Operations

Repeat accuracy R R

0.3 mm

Actuating speed, maximum

18 m/s

Mounting

rear with 2 threaded bolts

Mechanical data - Switching distances according EN IEC 60947-5-3

Switching distance S

5 mm … 55 mm

2 x BP 21S = 20 ... 55 mm

BP 34S = 10 ... 25 mm

BE 20 = 20 mm

BP 10N = 10 mm

BP 10S = 10 mm

2 x BP 10N = 15 mm

2 x BP 10S = 15 mm

BP 15N = 12 mm

BP 15S = 12 mm

2 x BP 15/2N = 17 mm

2 x BP 15/2S = 17mm

BP 34N = 10 ... 25mm

BP 20N = 5 ... 20 mm

BP 20S = 5 ... 20 mm

BP 31N = 5 ... 20 mm

BP 31S = 5 ... 20 mm

BP 11N = 10 mm

BP 11S = 10 mm

2 x BP 11N = 20 mm

2 x BP 11S = 20 mm

BP 12N = 15 mm

BP 12S = 15 mm

2 x BP 12N = 10 ... 25 mm

2 x BP 12S = 10 ... 25 mm

BP 21N = 15 ... 40 mm

BP 21S = 15 ... 40 mm

2 x BP 21N = 20 ... 55 mm

BE 20N = 15 mm

BE 20S = 15 mm

Note (Switching distance Sn)

Actuating distance up to 55 mm depending on actuating magnet and version. The specified switching distances are applicable for the actuation of individually mounted components without ferromagnetic influence. A change of the distance, either positive or negative, is possible due to ferromagnetic influences. The mutual interference between multiple actuating magnets must be observed.

Mechanical data - Connection technique

Type of connection

Cable outlet left and 2 shielding plates

Length of cable

1 m

Mechanical data - Dimensions

Length of sensor

24 mm

Width of sensor

85 mm

Height of sensor

26 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Resistance to vibration to EN 60068-2-6

10 … 55 Hz, amplitude 1 mm

Restistance to shock

50 g / 11 ms

Electrical data

Switching voltage, maximum

250 VAC

Switching current, maximum

3 A

Switching capacity, maximum

120 W

Switching capacity, maximum

120 VA

Switching element

bistable contact

Bounce duration, minimum

0.3 ms

Bounce duration, maximum

0.6 ms

Switching frequency, maximum

300 Hz

Electrical data - Digital Output

Design of switching elements

Reed contacts

Scope of delivery

Scope of delivery

Actuators must be ordered separately.

Accessory

Recommendation (actuator)

BP 10 S

2x BP 10 S

BP 15 S

BP 34 S

BP 20 S

BP 31 S

BP 11 S

2x BP 11 S

BP 12 S

BP 21 S

2x BP 21 S

BP 10 N

2x BP 10 N

BP 15 N

2 x BP 15/2 N

2x BP 15/2 S

BP 34 N

BP 20 N

BP 31 N

BP 11 N

2x BP 11 N

BP 12 N

2x BP 12 N

2x BP 12 S

BP 21 N

2x BP 21 N

BE 20

BE 20 N(S) ST 24VDC

BE 20 N(S) 48VDC

Recommendation (actuator, lift switchgear)

BP 10

2 x BP 15/2

2 x BP 10

BP 15

BP 34

Note

Note (General)

The opening and closing functions depend on the direction of actuation, the actuating magnets and the polarity of the actuating magnets.

Mounting and wiring instructions
  • BN 325

    Download
Operating instructions and Declaration of conformity
  • BN 325-R (G)

    Download
EC Declaration of conformity
  • Magnetic reed switch

    Download
Info
  • Magnetic reed switch - Actuating distances

    Download
  • Magnetic reed switch

    Download