Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

101086912 - IFL 4-12M-10STP

Description: Product type description:IFL (1)-(2)(3)-(4)(5)(6)(7)(8)-(9)(1)2Switching distance 2 mm 4Switching distance 4 mm NB, MBN, BNQuasi-embeddable(2)12Cylinder, thread M12, metal120Cylinder, thread M12, plastic(3)withoutStandard bodyMMiniature bodyLLong design(4)01Opener (NC)10Normally open contact (NO)10/01NO contact / NC contact with wiring compartment111 NO contact / 1 NC contact antivalent(5)withoutCableSTMale connectorTConductor with strain relief(6)withoutStandard connector version2Alternative conector version(7)Nn-typePp-type(8)KMax. fuse rating1pulsed(9)2033Stainless steel enclosure
Description: Product type description:IFL (1)-(2)(3)-(4)(5)(6)(7)(8)-(9)(1)2Switching distance 2 mm 4Switching distance 4 mm NB, MBN, BNQuasi-embeddable(2)12Cylinder, thread M12, metal120Cylinder, thread M12, plastic(3)withoutStandard bodyMMiniature bodyLLong design(4)01Opener (NC)10Normally open contact (NO)10/01NO contact / NC contact with wiring compartment111 NO contact / 1 NC contact antivalent(5)withoutCableSTMale connectorTConductor with strain relief(6)withoutStandard connector version2Alternative conector version(7)Nn-typePp-type(8)KMax. fuse rating1pulsed(9)2033Stainless steel enclosure
Productfeatures
  • Metal enclosure
  • DC 3-wire
  • miniature body
  • Connector M12
  • Design M12
Data
Ordering data

Product type description

IFL 4-12M-10STP

Article number (order number)

101086912

EAN (European Article Number)

4030661018089

eCl@ss number, version 9.0

27-27-01-01

eCl@ss number, version 11.0

27-27-01-01

ETIM number, version 7.0

EC002714

ETIM number, version 6.0

EC002714

General data

Standards

DIN VDE 0660-208

IEC/EN 60947-5-2

Housing construction form

Cylinder, thread

Installation conditions (mechanical)

not flush

Enclosure material

Brass

Enclosure coating material

nickel-plated

Active area

Plastic

Material of the nuts

Nickel plated brass

Gross weight

25 g

General data - Features

Integral system diagnostics, status

Yes

Number of cable wires

3

Mechanical data

Tightening torque of nuts, maximum

15 Nm

Note (Tightening torque of nuts)

In the shell core area: max. 500 Ncm

Mechanical data - Switching distances according EN IEC 60947-5-3

Switching distance

4 mm

Mechanical data - Connection technique

Type of connection

Connector M12

Mechanical data - Dimensions

ISO thread of the sensor

M12

width across flats

17 BK

Length of sensor

45.6 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Protection class

0

Electrical data

Voltage type

DC (direct current)

Operating voltage, minimum

10 V

Operating voltage, maximum

30 V

No-load supply current, maximum I

3 mA

Operating current

200 mA

Switching element

Normally open contact (NO)

Protection circuit integrated

inductive interference protection

Protection against polarity reversal

Surge protection

Max. fuse rating

Switching frequency, approx.

500 Hz

Electrical data - Digital Output

Voltage drop U

1.2 V

Current at Voltage drop U

0.2 A

Design of switching elements

p-type

Status indication

Note (Integral System Diagnostics, status )

yellow LED

Operating instructions (supplementary sheet/quick guide)
  • IFL Inductive proximity switch

    Download
EC Declaration of conformity
  • IFL Inductive proximity switch

    Download