Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

2857-535/000-001 - Temperature signal conditioner; Configuration via software; Supply voltage: 24 VDC

  • Brand: Wago
  • Product Code: 2857-535/000-001
Description: Short description: WAGOs RTD TC temperature signal conditioner for RTD sensors, potentiometers, resistors and thermocouples monitors and reports signals for up to two switching thresholds. The sensor and status information that is collected is also made available to a higher-order device (e.g., a PLC) via a bus connection. Features: A relay with changeover contact reacts to configured measurement range limits (on/off switching delay and threshold value switch function can be configured with up to two threshold values). Configurable Pt factor Adjustable software filter Simulation of input/output response via interface configuration display Input of customer-specific sensors via the interface configuration software Safe 3-way isolation with 3 kV test voltage per EN 61010-1 Output-end RS-485 interface with Modbus protocol Terminating resistor can be adjusted at the output Adjustable transfer characteristic
Description: Short description: WAGOs RTD TC temperature signal conditioner for RTD sensors, potentiometers, resistors and thermocouples monitors and reports signals for up to two switching thresholds. The sensor and status information that is collected is also made available to a higher-order device (e.g., a PLC) via a bus connection. Features: A relay with changeover contact reacts to configured measurement range limits (on/off switching delay and threshold value switch function can be configured with up to two threshold values). Configurable Pt factor Adjustable software filter Simulation of input/output response via interface configuration display Input of customer-specific sensors via the interface configuration software Safe 3-way isolation with 3 kV test voltage per EN 61010-1 Output-end RS-485 interface with Modbus protocol Terminating resistor can be adjusted at the output Adjustable transfer characteristic
  • Available Quantity: 0

$654.50

Technical data
Configuration

Configuration options

WAGO Interface Configuration Software

WAGO Configuration Display

WAGO Interface Configuration App

Rotary encoder switch

Input

Input signal type

RTD sensors

Potentiometer

Resistance

TC sensors

Input – RTD sensors

Sensor types (RTD)

Pt10 … Pt2000 (expandable)

Sensor connection

2-wire; 3-wire; 4-wire; differential; potentiometer

Sensor power supply (RTD) max.

≤ 0.5 mA

Temperature measurement range (RTD)

-200 … 850°C

Measurement span (RTD) min.

50

Input – TC sensors

Sensor types (TC)

Type J

Type K

Type E

Type R

Type N

Type S

Type T

Type B

Type C

Temperature measurement range (TC)

-210 … 1200 °C (Type J); -200 … 1372 °C (Type K); -200 … 1000 °C (Type E); 250 … 1768 °C (Type R); -200 … 1300 °C (Type N); -50 … 1664 °C (Type S); -200 … 400 °C (Type T); 250 … 1820 °C (Type B); 0 … 2320 °C (Type C)

Measurement span (TC) min.

100

Cold junction compensation

ON/OFF (default: ON)

Cold junction error

3 K (typ. 2 K )

Input – resistors

Input range (resistor)

0 … 10 kΩ

Input range (potentiometer)

0 … 10 kΩ

Measurement span (min.)

50

Output – MODBUS

Number of devices (max.)

64

Addressing

via rotary encoder switch: 1 … 99
via service interface: 1 … 247 (rotary encoder switch set to “0”)

Parity

Even; others can be configured

Connector

6 x picoMAX® for daisy chain configuration

Bus length (max.)

1000

Terminating resistor

Can be activated; 150 Ω; 120 Ω + 1 nF

Parameter

Read input registers (0x04):

  • Measured value: address (0x0000); data type (float); access (read)
  • Relay status: address (0x0002); data type (word); access (read)

Output – relay

Dielectric strength (open contact) (AC, 1 min)

1

Number of changeover contacts

1

Switching voltage (max.)

AC 250 V

Limiting continuous current (relay; module assembly)

6 A (≤ 60 °C); 3 A (60 … 70 °C)

Dielectric strength (open contact) (AC, 1 min)

1 kVrms

Number of switching thresholds (relay)

1 or 2 (adjustable)

Configurable rise/fall delay time (relay)

0 … 60 s (via software)

Communication

Communication

Modbus® RTU

Interface

RS-485 (2-wire)

Number of devices (max.)

64

Bus length (max.)

≤ 1000 m

Baud rate

9.6 kBd … 19.2 kBd

Terminating resistor

Can be activated; 150 Ω; 120 Ω + 1 nF

Addressing

via rotary encoder switch: 1 … 99
via service interface: 1 … 247 (rotary encoder switch set to “0”)

Signal processing

Software filter (adjustable)

Moving average value (filter level: 30)

Step response (typ.)

130 ms (2-wire); 700 ms (3-wire); 700 ms (4-wire); 600 ms (Differential); 500 ms (Potentiometer); 150 ms (Cold junction compensation (OFF)); 400 ms (Cold junction compensation (ON))

Measurement error

Transmission error (typ.)

≤ 0.1 % at full measurement span

Transmission error for the set measurement range

≤ (100 K/set measurement range [K]) %

Temperature coefficient

≤ 0.01 %/K

Supply

Power supply type

24 VDC

Nominal supply voltage US

DC 24 V

Supply voltage range

-60 … +30 %

Current consumption at nominal supply voltage

≤ 50 mA

Notes

Note

This product is supplied with 24 VDC, which can be commoned using lateral push-in type jumper bars: (6.1) US+ (BR) and (6.2) GND 2 (BR). With this variant, it is necessary to ensure that the maximum permissible total current of 1 A is not exceeded.

Safety and protection

Rated voltage of the measurement circuit connections per EN 61010-2-030

AC 300 V

Measurement category per EN/UL 61010-2-030

CAT II (input)

Note on insulation parameters

The service interface is located on the service interface potential.

The DIN-rail contact (functional ground) is capacitively coupled to the communication interface.

Protection type

IP20

Connection data

Connection technology

Push-in CAGE CLAMP®

WAGO connector

picoMAX® 5.0

Solid conductor

0.2 … 2.5 mm² / 24 … 12 AWG

Fine-stranded conductor

0.2 … 2.5 mm² / 24 … 12 AWG

Strip length

9 … 10 mm / 0.35 … 0.39 inches

Connector

6 x picoMAX® for daisy chain configuration

Physical data

Width

22.5 mm / 0.886 inches

Height

110 mm / 4.331 inches

Depth from upper-edge of DIN-rail

107 mm / 4.213 inches

Mechanical data

Mounting type

DIN-35 rail

Material data

Fire load

1.796

Weight

13

Environmental requirements

Pollution degree

2

Ambient temperature (operation)

-40 … +70 °C

Surrounding air temperature (storage)

-40 … +85 °C

Temperature range of connection cable per EN 61010-2-201

≥ (Tambient + 10 K)

Temperature range of connection cable per UL 61010-2-201 (min.)

90

Relative humidity

5 … 95 % (non-condensing)

Operating altitude (max.)

2000

Standards and specifications

Conformity marking

CE

EMC immunity to interference

EN 61000-6-2; EN 61326-2-3

EMC emission of interference

EN 61000-6-3; EN 61326-2-3

Standards/specifications

EN 61010-1

EN 61373

Bid Text
  • 2857-535/000-001

    Download
  • 2857-535/000-001

    Download
Instruction Leaflet
  • Signal Conditioner; RTD TC Temperature Signal Conditioner; Serial

    Download
Additional Information
  • Disposal; Electrical and electronic equipment, Packaging

    Download
Software for Interface-Products
  • WAGO Interface Configuration Software G2 SMALL

    Download
  • WAGO Interface Configuration Software G2 FULL

    Download
CAE data
  • EPLAN Data Portal 2857-535/000-001

    Download
  • ZUKEN Portal 2857-535/000-001

    Download
  • EPLAN Data Portal 2857-535/000-001

    Download
CAD data
  • 2D/3D Models 2857-535/000-001

    Download
Compliance Search
  • Environmental Product Compliance 2857-535/000-001

    Download