101180845 - AES 2535 UE: 24...230V AC/DC
- Brand: Schmersal
- Product Code: 101180845
- Monitoring of BNS range magnetic safety sensors
- 4 safety contacts, STOP 0
- 2 Signalling outputs
Data
Ordering data
Note (Delivery capacity) | Phased-out product |
Product type description | AES 2535 UE: 24...230V AC/DC |
Article number (order number) | 101180845 |
EAN (European Article Number) | 4030661343570 |
eCl@ss number, version 9.0 | 27-37-18-19 |
eCl@ss number, version 11.0 | 27-37-18-19 |
eCl@ss number, version 12.0 | 27-37-18-19 |
ETIM number, version 7.0 | EC001449 |
ETIM number, version 6.0 | EC001449 |
Available until | 01.12.2021 |
Approvals - Standards
Certificates | BG cULus EAC |
General data
Standards | BG-GS-ET-14 BG-GS-ET-20 EN 60947-5-1 IEC 60947-5-3 IEC 61508 IEC/EN 60204-1 |
Climatic stress | BG-GS-ET-14 IEC 60947-5-3 |
Enclosure material | Glass-fibre, reinforced thermoplastic |
Material of the contacts, electrical | Ag-Ni 10 and 0.2 µm gold-plated |
Gross weight | 359 g |
General data - Features
Stop-Category | 0 |
Wire breakage detection | Yes |
Cross-circuit detection | Yes |
Feedback circuit | Yes |
Automatic reset function | Yes |
Reset after disconnection of supply voltage | Yes |
Integral system diagnostics, status | Yes |
Number of auxiliary contacts | 1 |
Number of LEDs | 1 |
Number of openers | 2 |
Number of shutters | 1 |
Number of undelayed semi-conductor outputs with signaling function | 2 |
Number of safety contacts | 4 |
Number of signalling outputs | 2 |
Mechanical data
Mechanical life, minimum | 20,000,000 Operations |
Mounting | Snaps onto standard DIN rail to EN 60715 |
Mechanical data - Connection technique
Type of connection | Screw terminals M20 x 1.5 rigid or flexible |
Terminal designations | IEC/EN 60947-1 |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 2.5 mm² |
Tightening torque of Clips | 0.6 Nm |
Mechanical data - Dimensions
Width | 45 mm |
Height | 100 mm |
Depth | 121 mm |
Ambient conditions
Degree of protection of the enclosure | IP40 |
Degree of protection of the mounting space | IP54 |
Degree of protection of clips or terminals | IP20 |
Ambient temperature, minimum | +0 °C |
Ambient temperature, maximum | +55 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +70 °C |
Resistance to vibration to EN 60068-2-6 | 10...55 Hz, Amplitude 0.35 mm, ± 15 % |
Restistance to shock | 30 g / 11 ms |
Ambient conditions - Insulation values
Rated impulse withstand voltage U | 4 kV |
Overvoltage category | III |
Degree of pollution to IEC/EN 60664-1 | 2 |
Electrical data
Frequency range | 50 Hz 60 Hz |
Thermal test current | 6 A |
Rated operating voltage | 24 ... 230 VAC/DC |
Rated AC voltage for controls, 50 Hz, minimum | 20.4 VAC |
Rated control voltage at AC 50 Hz, maximum | 253 VAC |
Rated AC voltage for controls, 60 Hz, minimum | 20.4 VAC |
Rated control voltage at AC 60 Hz, maximum | 253 VAC |
Rated AC voltage for controls at DC minimum | 20.4 VDC |
Rated control voltage at DC, maximum | 253 VDC |
Electrical power consumption | 5 W |
Contact resistance, maximum | 0.1 Ω |
Note (Contact resistance) | in new state |
Drop-out delay in case of power failure, typically | 80 ms |
Drop-out delay in case of emergency, typically | 20 ms |
Pull-in delay at automatic start, maximum, typically | 100 ms |
Pull-in delay at RESET, typically | 20 ms |
Electrical data - Safe relay outputs
Voltage, Utilisation category AC-15 | 230 VAC |
Current, Utilisation category AC-15 | 3 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 2 A |
Switching capacity, minimum | 10 VDC |
Switching capacity, minimum | 10 mA |
Switching capacity, maximum | 250 VAC |
Switching capacity, maximum | 8 A |
Electrical data - Digital inputs
Input signal, HIGH Signal "1" | 10 … 30 VDC |
Input signal, LOW Signal "0" | 0 … 2 VDC |
Conduction resistance, maximum | 40 Ω |
Electrical data - Digital Output
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.1 A |
Electrical data - Relay outputs (auxiliary contacts)
Switching capacity, maximum | 24 VDC |
Switching capacity, maximum | 2 A |
Electrical data - Electromagnetic compatibility (EMC)
EMC rating | EMC-Directive |
Integral system diagnosis (ISD)
Note (ISD -Faults) | The following faults are registered by the safety monitoring modules and indicated by ISD. |
Faults | Failure of the safety relay to pull-in or drop-out Failure of door contacts to open or close Cross-wire or short-circuit monitoring of the switch connections Interruption of the switch connections Fault on the input circuits or the relay control circuits of the safety monitoring module Failure of or functional fault on the safety relay |
Other data
Note (applications) | Safety sensor Guard system |
AES - BG-GS-ET-20 - AES 2135 / AES 2136 / AES 2335 / AES 2336 / AES 2355 / AES 2356 / AES 2365 / AES 2366 / AES 2535 / AES 2536 / AES 2555 / AES 2556 / AES 2565 / AES 2566
AES and BNS - BG-GS-ET-14 - AES 2135 / AES 2136 / AES 2335 / AES 2336 / AES 2355 / AES 2356 / AES 2365 / AES 2366 / AES 2535 / AES 2536 / AES 2555 / AES 2556 / AES 2565 / AES 2566