Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

101180845 - AES 2535 UE: 24...230V AC/DC

Description: Product type description:AES 253(1)(1)215without start-up test6with start-up test
Description: Product type description:AES 253(1)(1)215without start-up test6with start-up test
Productfeatures
  • Monitoring of BNS range magnetic safety sensors
  • 4 safety contacts, STOP 0
  • 2 Signalling outputs
Data
Ordering data

Note (Delivery capacity)

Phased-out product

Product type description

AES 2535 UE: 24...230V AC/DC

Article number (order number)

101180845

EAN (European Article Number)

4030661343570

eCl@ss number, version 9.0

27-37-18-19

eCl@ss number, version 11.0

27-37-18-19

eCl@ss number, version 12.0

27-37-18-19

ETIM number, version 7.0

EC001449

ETIM number, version 6.0

EC001449

Available until

01.12.2021

Approvals - Standards

Certificates

BG

cULus

EAC

General data

Standards

BG-GS-ET-14

BG-GS-ET-20

EN 60947-5-1

IEC 60947-5-3

IEC 61508

IEC/EN 60204-1

Climatic stress

BG-GS-ET-14

IEC 60947-5-3

Enclosure material

Glass-fibre, reinforced thermoplastic

Material of the contacts, electrical

Ag-Ni 10 and 0.2 µm gold-plated

Gross weight

359 g

General data - Features

Stop-Category

0

Wire breakage detection

Yes

Cross-circuit detection

Yes

Feedback circuit

Yes

Automatic reset function

Yes

Reset after disconnection of supply voltage

Yes

Integral system diagnostics, status

Yes

Number of auxiliary contacts

1

Number of LEDs

1

Number of openers

2

Number of shutters

1

Number of undelayed semi-conductor outputs with signaling function

2

Number of safety contacts

4

Number of signalling outputs

2

Mechanical data

Mechanical life, minimum

20,000,000 Operations

Mounting

Snaps onto standard DIN rail to EN 60715

Mechanical data - Connection technique

Type of connection

Screw terminals M20 x 1.5

rigid or flexible

Terminal designations

IEC/EN 60947-1

Cable section, minimum

0.25 mm²

Cable section, maximum

2.5 mm²

Tightening torque of Clips

0.6 Nm

Mechanical data - Dimensions

Width

45 mm

Height

100 mm

Depth

121 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+55 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+70 °C

Resistance to vibration to EN 60068-2-6

10...55 Hz, Amplitude 0.35 mm, ± 15 %

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation values

Rated impulse withstand voltage U

4 kV

Overvoltage category

III

Degree of pollution to IEC/EN 60664-1

2

Electrical data

Frequency range

50 Hz

60 Hz

Thermal test current

6 A

Rated operating voltage

24 ... 230 VAC/DC

Rated AC voltage for controls, 50 Hz, minimum

20.4 VAC

Rated control voltage at AC 50 Hz, maximum

253 VAC

Rated AC voltage for controls, 60 Hz, minimum

20.4 VAC

Rated control voltage at AC 60 Hz, maximum

253 VAC

Rated AC voltage for controls at DC minimum

20.4 VDC

Rated control voltage at DC, maximum

253 VDC

Electrical power consumption

5 W

Contact resistance, maximum

0.1 Ω

Note (Contact resistance)

in new state

Drop-out delay in case of power failure, typically

80 ms

Drop-out delay in case of emergency, typically

20 ms

Pull-in delay at automatic start, maximum, typically

100 ms

Pull-in delay at RESET, typically

20 ms

Electrical data - Safe relay outputs

Voltage, Utilisation category AC-15

230 VAC

Current, Utilisation category AC-15

3 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

2 A

Switching capacity, minimum

10 VDC

Switching capacity, minimum

10 mA

Switching capacity, maximum

250 VAC

Switching capacity, maximum

8 A

Electrical data - Digital inputs

Input signal, HIGH Signal "1"

10 … 30 VDC

Input signal, LOW Signal "0"

0 … 2 VDC

Conduction resistance, maximum

40 Ω

Electrical data - Digital Output

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.1 A

Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum

24 VDC

Switching capacity, maximum

2 A

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMC-Directive

Integral system diagnosis (ISD)

Note (ISD -Faults)

The following faults are registered by the safety monitoring modules and indicated by ISD.

Faults

Failure of the safety relay to pull-in or drop-out

Failure of door contacts to open or close

Cross-wire or short-circuit monitoring of the switch connections

Interruption of the switch connections

Fault on the input circuits or the relay control circuits of the safety monitoring module

Failure of or functional fault on the safety relay

Other data

Note (applications)

Safety sensor

Guard system

Operating instructions and Declaration of conformity
  • AES 2335 / AES 2336 / AES 2535 / AES 2536

    Download
BG-test certificate
  • AES - BG-GS-ET-20 - AES 2135 / AES 2136 / AES 2335 / AES 2336 / AES 2355 / AES 2356 / AES 2365 / AES 2366 / AES 2535 / AES 2536 / AES 2555 / AES 2556 / AES 2565 / AES 2566

    Download
  • AES and BNS - BG-GS-ET-14 - AES 2135 / AES 2136 / AES 2335 / AES 2336 / AES 2355 / AES 2356 / AES 2365 / AES 2366 / AES 2535 / AES 2536 / AES 2555 / AES 2556 / AES 2565 / AES 2566

    Download
UL Certificate
  • (385.6 kB, 08/01/2019)

    Download
Force-travel diagram
  • AES 2135 / AES 2136 / AES 2336 / AES 2335 / AES 2536 / AES 2535 / AES 2365 / AES 2366 / AES 2565 / AES 2566

    Download
SISTEMA-VDMA library
  • (131.9 kB, 12/09/2021)

    Download
  • SISTEMA

    Download