Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

103016120 - SLG240COM-ER-0500-02

Description: Product type description:SLG240COM-ER-(1)(1)0500-02Distance between outermost beams 500 mm, 2-beam0800-03Distance between outermost beams 800 mm, 3-beam0900-04Distance between outermost beams 900 mm, 4-beam
Description: Product type description:SLG240COM-ER-(1)(1)0500-02Distance between outermost beams 500 mm, 2-beam0800-03Distance between outermost beams 800 mm, 3-beam0900-04Distance between outermost beams 900 mm, 4-beam
Productfeatures
  • Safety type 2 in accordance with IEC 61496-1
  • User-friendly parameter setting, no tools required
  • Reliable safety concept in case of interferences (EMC, welding sparks)
  • Process safety with highest availability
  • active integrated set-up tool
Data
Ordering data

Product type description

SLG240COM-ER-0500-02

Article number (order number)

103016120

EAN (European Article Number)

4030661506531

eCl@ss number, version 9.0

27-27-27-03

eCl@ss number, version 11.0

27-27-27-03

eCl@ss number, version 12.0

27-27-27-03

ETIM number, version 7.0

EC001832

ETIM number, version 6.0

EC001832

Approvals - Standards

Certificates

TÜV

cULus

General data

Standards

EN 61496-1

EN 61496-2

Master- or Slave-function

Yes

Enclosure material

Aluminium

Gross weight

940 g

Reaction time, maximum

10 ms

General data - Features

Cascadable

Yes

Restart interlock (manual reset)

Yes

Hide function

Yes

Integral system diagnostics, status

Yes

Integral system diagnostics

Yes

Number of beams

2

Number of fail-safe digital outputs

2

Mechanical data

Detection ability for test bodies at v = 1.6 m/s

500 mm

Height of the protection field

500 mm

Range, protection field, minimum

300 mm

Range, protection field, maximum

12,000 mm

Wave length of the sensor

880 nm

Mechanical data - Connection technique

Type of connection

Connector

Length of cable

100 m

Terminal connector, Recipient

Connector plug M12, 5-pole

Terminal, Connector, Transmitter

Connector plug M12, 4-pole

Mechanical data - Dimensions

Length of sensor

33 mm

Width of sensor

27.8 mm

Height of sensor

571 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature, minimum

-10 °C

Ambient temperature, maximum

+50 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+70 °C

Protection class

III

Electrical data

Voltage type

DC (direct current)

Switching voltage OSSD, HIGH signal

24 V

Electrical power consumption of the receiver, maximum

10 W

Electrical power consumption of the transmitter, maximum

5 W

Electrical data - Safety digital outputs

Output current, (fail-safe output), maximum

0.25 A

Design of switching elements

p-type

Scope of delivery

Scope of delivery

Kit with 2 mounting angles

Operating instructions and Declaration of conformity
  • SLC240COM / SLG240COM

    Download
UL Certificate
  • (422.3 kB, 08/01/2019)

    Download
Brochure
  • Optoelectronic safety devices

    Download
SISTEMA-VDMA library
  • (131.9 kB, 12/09/2021)

    Download
  • TraceParts

    Download
  • CADENAS

    Download
  • SISTEMA

    Download