- Can be used for CSS and RSS sensors, as well as for MZM 100, AZM 201, AZM 300, AZM40
- Safe active AS-i distributor
- Connections for profile cable AS-i & AUX
- With 2 fail-safe inputs for OSSDs and one digital output that is not fail-safe
- M12, 8-pole connecting cable 1 m
- Protection class IP67
Data
Ordering data
Product type description | BWU3635 |
Article number (order number) | 103016678 |
EAN (European Article Number) | 4030661508924 |
eCl@ss number, version 9.0 | 27-24-26-04 |
eCl@ss number, version 11.0 | 27-24-26-04 |
eCl@ss number, version 12.0 | 27-24-26-04 |
ETIM number, version 7.0 | EC001599 |
ETIM number, version 6.0 | EC001599 |
General data
Standards | EN 62026-2 EN 62061 EN ISO 13849-1 |
Enclosure material | Plastic |
Gross weight | 141.3 g |
Reaction time, maximum | 11 ms |
General data - Features
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Mechanical data - Connection technique
Type of connection | Cable connector M12, 8-pole, A-coded |
Length of cable | 1 m |
Material of the cable | PUR |
Mechanical data - Dimensions
Width | 60 mm |
Height | 45 mm |
Depth | 19 mm |
Ambient conditions
Degree of protection | IP67 |
Ambient temperature, minimum | -20 °C |
Ambient temperature, maximum | +60 °C |
Storage and transport temperature, minimum | -30 °C |
Storage and transport temperature, maximum | +85 °C |
Resistance to vibration to EN 60068-2-6 | 10 … 55 Hz, amplitude 0.5 mm |
Restistance to shock | 15 g / 11 ms |
Electrical data - AS Interface
AS-i Operating voltage, minimum | 21.6 VDC |
AS-i Operating voltage AS-i maximum | 31.6 VDC |
AS-i Current consumption, maximum | 60 mA |
Electrical data - AS-Interface specification
AS-i Specification | Safety-Slave |
AS-i Version | V 2.1 |
AS-i Profile | S-7.B.F.1 |
AS-i Input, Channel 1 | Data bits DI 0 / DI 1 = dynamic code transmission |
AS-i Input, Channel 2 | Data bits DI 2 / DI 3 = dynamic code transmission |
AS-i Outputs, DO 0 | Digital output, Solenoid control |
AS-i Outputs, DO 1 … DO 3 | No Function |
AS-i Parameter bits, P0 | Control system watchdog |
AS-i Parameter bits, P1 | Diagnostics signal safety switchgear (inverted) |
AS-i Parameter bits, P2 ... P3 | No function |
Note (AS-i Parameter bits) | Set the parameter outputs to "1111" (0xF) |
AS-i Input module address | 0 |
Note (AS-i Input module address) | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Electrical data - Auxiliary voltage
Rated operating voltage | 24 VDC -15% / +10% (stabilised PELV) |