101209056 - MZM 100 B ST2-1P2PW2RM-A

Description: Product type description:MZM 100(1)(2)(3)(4)(5)(1)withoutSolenoid interlock monitoredBActuator monitored(2)ST2Connector plug M12, 8-poleSTConnector plug M23, 8+1-pole(3)1P2P1 p-type diagnostic output and 2 p-type safety outputs (only in connection with Solenoid interlock monitored)1P2PWserial diagnostic output and 2 p-type safety outputs(4)withoutelectrically adjustable latching force 30 … 100 N(5)
Description: Product type description:MZM 100(1)(2)(3)(4)(5)(1)withoutSolenoid interlock monitoredBActuator monitored(2)ST2Connector plug M12, 8-poleSTConnector plug M23, 8+1-pole(3)1P2P1 p-type diagnostic output and 2 p-type safety outputs (only in connection with Solenoid interlock monitored)1P2PWserial diagnostic output and 2 p-type safety outputs(4)withoutelectrically adjustable latching force 30 … 100 N(5)
Productfeatures
  • Connector M12, 8-pole
  • Power to lock
  • Automatic latching
  • Solenoid interlocks (for the protection of man) with innovating and unique operating principle
  • 40 mm x 179 mm x 40 mm
  • Electronic contact-free, coded system
  • Thermoplastic enclosure
  • Max. length of the sensor chain 200 m
  • 3 LEDs to show operating conditions
  • Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
  • Intelligent diagnosis
  • Self-monitoring series-wiring
  • Patented
Data
Ordering data

Product type description

MZM 100 B ST2-1P2PW2RM-A

Article number (order number)

101209056

EAN (European Article Number)

4030661389752

eCl@ss number, version 9.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 12.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Approvals - Standards

Certificates

TÜV

cULus

EAC

General data

Standards

EN 60947-5-3

EN ISO 13849-1

EN ISO 14119

IEC 61508

Coding

Universal coding

Coding level according to ISO 14119

Low

Working principle

inductive

Enclosure material

Glass-fibre, reinforced thermoplastic

Gross weight

632 g

Time to readiness, maximum

4,000 ms

Reaction time, maximum

150 ms

Duration of risk, maximum

150 ms

General data - Features

Power to lock

Yes

Actuator monitored

Yes

Latching

Yes

Short circuit detection

Yes

Cross-circuit detection

Yes

Series-wiring

Yes

Safety functions

Yes

Integral system diagnostics, status

Yes

Number of safety contacts

2

Number of series-wiring of sensors

31

Safety classification - Interlocking function

Performance Level, up to

e

Category

4

PFH value

3.54 x 10⁻⁹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Note (Mechanical life)

Actuating speed < 0.5 m/s

Operations for door weights ≤ 5 kg

Holding force, typically

750 N

Holding force, guaranteed

500 N

Latching force

45 N

Mechanical data - Connection technique

Type of connection

Connector M12, 8-pole

Mechanical data - Dimensions

Length of sensor

40 mm

Width of sensor

40 mm

Height of sensor

179 mm

Ambient conditions

Degree of protection

IP65

IP67

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+55 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+70 °C

Relative humidity, minimum

30 %

Relative humidity, maximum

95 %

Note (Relative humidity)

non-condensing

non-icing

Resistance to vibration to EN 60068-2-6

10 … 150 Hz, amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Protection class

III

Ambient conditions - Insulation values

Rated insulation voltage U

32 VDC

Rated impulse withstand voltage U

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data

Operating voltage, minimum

20.4 VDC

Operating voltage, maximum

26.4 VDC

No-load supply current, maximum I

600 mA

Operating current

50 mA

Required rated short-circuit current to EN 60947-5-1

100 A

Note

Cable length and cable section alter the voltage drop depending on the output current

Switching frequency, maximum

1 Hz

Electrical data - Magnet control

Switching thresholds

-3 V … 5 V (Low)

15 V … 30 V (High)

Classification ZVEI CB24I, Sink

C0

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Safety digital inputs

Switching thresholds

−3 V … 5 V (Low)

15 V … 30 V (High)

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Safety digital outputs

Rated operating current (safety outputs)

250 mA

Voltage drop U

1 V

Leakage current I

0.5 mA

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.25 A

Classification ZVEI CB24I, Source

C1

Classification ZVEI CB24I, Sink

C1

Electrical data - Diagnostic outputs

Voltage drop U

2 V

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.05 A

Status indication

Note (LED switching conditions display)

Operating condition: LED green

Error / functional defect: LED red

Supply voltage UB: LED green

Pin assignment

PIN 1

A1 Supply voltage UB

PIN 2

X1 Safety input 1

PIN 3

A2 GND

PIN 4

Y1 Safety output 1

PIN 5

OUT Diagnostic output

PIN 6

X2 Safety input 2

PIN 7

Y2 Safety output 2

PIN 8

IN Solenoid control

Scope of delivery

Scope of delivery

Actuators must be ordered separately.

Accessory

Recommendation (actuator)

MZM 100-B1.1

Operating instructions and Declaration of conformity
  • MZM 100 / MZM 100 B

    Download
UL Certificate
  • (413.4 kB, 08/01/2019)

    Download
Brochure
  • Electronic Safety Sensors and Solenoid Interlocks

    Download
SISTEMA-VDMA library
  • (131.9 kB, 12/09/2021)

    Download
  • TraceParts

    Download
  • SISTEMA

    Download