Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

103012540 - EX-AZM300B-ST-1P2P-A-CR

Description: Product type description:EX-AZM300(1)(2)-ST(3)(4)(5)(1)ZGuard locking monitored >NB, MBN, BNActuator monitored(2)withoutStandard codingI1Individual codingI2Individual coding, multiple teaching(3)1P2P1 p-type diagnostic output and 2 p-type safety outputsSD2Pserial diagnostic output and 2 p-type safety outputs(4)withoutPower to unlockAPower to lock(5)CLWith protective enclosure, door hinge leftCRWith protective enclosure, door hinge right
Description: Product type description:EX-AZM300(1)(2)-ST(3)(4)(5)(1)ZGuard locking monitored >NB, MBN, BNActuator monitored(2)withoutStandard codingI1Individual codingI2Individual coding, multiple teaching(3)1P2P1 p-type diagnostic output and 2 p-type safety outputsSD2Pserial diagnostic output and 2 p-type safety outputs(4)withoutPower to unlockAPower to lock(5)CLWith protective enclosure, door hinge leftCRWith protective enclosure, door hinge right
Productfeatures
  • Explosion protection for ATEX Zones 2 and 22
  • RFID-technology for needs-based protection against tampering
  • Thermoplastic enclosure
  • Suitable for mounting to profile systems
  • 3 different directions of actuation
  • 3 LEDs to show operating conditions
  • Suitable for hinged and sliding guards
  • Series-wiring
  • Manual release
Data
Ordering data

Product type description

EX-AZM300B-ST-1P2P-A-CR

Article number (order number)

103012540

EAN (European Article Number)

4030661483917

eCl@ss number, version 9.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 12.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Explosion protection

Explosion protection: regulations

EN 60079-0

EN 60079-11

EN 60079-31

Explosion protection zones

22

2

Explosion protection category

3D

3G

Explosion protection designation

II 3GD

EX nA IIB T5 Gc

EX tc IIIB T95°C Dc X

General data

Standards

EN ISO 13849-1

IEC 60947-5-1

IEC 60947-5-3

IEC 61508

Coding level according to ISO 14119

Low

Working principle

RFID

Enclosure material

Glass-fibre, reinforced thermoplastic

Material of the fixing screws

Stainless steel (V4A)

Gross weight

1,056 g

Time to readiness, maximum

5,000 ms

Reaction time, maximum

120 ms

Duration of risk, maximum

200 ms

Reaction time, switching off safety outputs via actuator, maximum

100 ms

Reaction time, switching off safety outputs via safety inputs, maximum

0.5 ms

General data - Features

Power to lock

Yes

Actuator monitored

Yes

Latching

Yes

Manual release

Yes

Short circuit detection

Yes

Cross-circuit detection

Yes

Series-wiring

Yes

Safety functions

Yes

Integral system diagnostics, status

Yes

Number of safety contacts

2

Safety classification - Interlocking function

Performance Level, up to

e

Category

4

PFH value

5.20 x 10⁻¹⁰ /h

PFD value

4.50 x 10⁻⁵

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Note (Mechanical life)

When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)

Impact energy, maximum

7 J

Holding force in accordance with EN ISO 14119 F

1,150 N

Holding force, maximum F

1,500 N

Latching force, adjustable, position 1

25 N

Latching force, adjustable, position 2

50 N

Type of the fixing screws

2x M6

Mechanical data - Switching distances according EN IEC 60947-5-3

Assured switching distance "ON" S

1 mm

Assured switching distance "OFF" S

20 mm

Mechanical data - Connection technique

Type of connection

Connector M12, 8-pole, A-coded

Mechanical data - Dimensions

Width of sensor

85 mm

Ambient conditions

Degree of protection

IP67

IP69

IP66

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+50 °C

Storage and transport temperature, minimum

-10 °C

Storage and transport temperature, maximum

+90 °C

Resistance to vibration to EN 60068-2-6

10 … 150 Hz, amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Protection class

III

Ambient conditions - Insulation values

Rated insulation voltage U

32 VDC

Rated impulse withstand voltage U

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data

No-load supply current, maximum I

100 mA

Operating current

50 mA

Required rated short-circuit current to EN 60947-5-1

100 A

Switching frequency, approx.

0.5 Hz

Electrical data - Magnet control

Switching thresholds

-3 V … 5 V (Low)

15 V … 30 V (High)

Current consumption at 24V

10 mA

Classification ZVEI CB24I, Sink

C0

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Safety digital inputs

Switching thresholds

−3 V … 5 V (Low)

15 V … 30 V (High)

Current consumption at 24V

5 mA

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Safety digital outputs

Rated operating current (safety outputs)

250 mA

Design of switching elements

short-circuit proof, p-type

Voltage drop U

4 V

Leakage current I

0.5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.25 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.25 A

Classification ZVEI CB24I, Source

C2

Classification ZVEI CB24I, Sink

C1

C2

Electrical data - Diagnostic outputs

Design of switching elements

short-circuit proof, p-type

Voltage drop U

4 V

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.05 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.05 A

Status indication

Note (LED switching conditions display)

Operating condition: LED green

Error / functional defect: LED red

Supply voltage UB: LED green

Pin assignment

PIN 1

A1 Supply voltage UB

PIN 2

X1 Safety input 1

PIN 3

A2 GND

PIN 4

Y1 Safety output 1

PIN 5

OUT Diagnostic output

PIN 6

X2 Safety input 2

PIN 7

Y2 Safety output 2

PIN 8

IN Solenoid control

Scope of delivery

Scope of delivery

Actuators must be ordered separately.

Operating instructions and Declaration of conformity
  • EX-AZM300

    Download
  • EX-AZM300

    Download
  • EX-AZM300 (3GD)

    Download
TÜV certification
  • AZM300 , AZ300 , AZM300-AS

    Download
SISTEMA-VDMA library
  • (131.9 kB, 12/09/2021)

    Download
  • SISTEMA

    Download