Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

103027848 - AZ201-I1-ST-T-AS

Description: Product type description:AZM201(1)-(2)-ST-T-AS-(3)-P(1)ZSolenoid interlock monitoredNB, MBN, BNActuator monitoredBZCombined monitoring of actuator and solenoid interlock(2)I1Individual codingI2Individual coding, re-teaching enabled(3)withoutPower to unlock (spring-operated locking)APower to lock (magnet-operated locking)PwithoutMagnet supply 24 VDC (AUX)
Description: Product type description:AZM201(1)-(2)-ST-T-AS-(3)-P(1)ZSolenoid interlock monitoredNB, MBN, BNActuator monitoredBZCombined monitoring of actuator and solenoid interlock(2)I1Individual codingI2Individual coding, re-teaching enabled(3)withoutPower to unlock (spring-operated locking)APower to lock (magnet-operated locking)PwithoutMagnet supply 24 VDC (AUX)
Productfeatures
  • Safety switch with separate actuator
  • Thermoplastic enclosure
  • Integrated AS-Interface
  • 40 mm x 220 mm x 50 mm
  • 3 LEDs to show operating conditions
  • Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
  • Intelligent diagnosis
  • With door detection sensor T
  • Protection class IP67
Data
Ordering data

Product type description

AZ201-I1-ST-T-AS

Article number (order number)

103027848

EAN (European Article Number)

4030661524368

eCl@ss number, version 9.0

27-27-26-02

eCl@ss number, version 11.0

27-27-26-02

eCl@ss number, version 12.0

27-27-26-02

ETIM number, version 7.0

EC002592

ETIM number, version 6.0

EC002592

Approvals - Standards

Certificates

TÜV

cULus

ASi-SaW

EAC

FCC

IC

General data

Standards

EN 62026-2

EN ISO 13849-1

EN ISO 14119

IEC 60947-5-3

IEC 61508

IEC 62061

Coding

Individual coding

Coding level according to ISO 14119

High

Working principle

RFID

Enclosure material

Glass-fibre, reinforced thermoplastic

Gross weight

351 g

Time to readiness, maximum

4,000 ms

Reaction time, maximum

100 ms

Duration of risk, maximum

200 ms

General data - Features

Latching

Yes

Safety functions

Yes

Integral system diagnostics, status

Yes

Number of actuating directions

2

Safety classification - Interlocking function

Performance Level, up to

e

Category

4

PFH value

1.81 x 10⁻⁹ /h

PFD value

1.59 x 10⁻⁴

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Latching force

30 N

Actuating speed, maximum

0.2 m/s

Tightening torque of the fixing screws, maximum

8 Nm

Mechanical data - Connection technique

Type of connection

Connector plug M12, 4-pole, (A-coding)

Mechanical data - Dimensions

Length of sensor

50 mm

Width of sensor

40 mm

Height of sensor

220 mm

Ambient conditions

Degree of protection

IP67

IP66

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+65 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Relative humidity, minimum

10 %

Relative humidity, maximum

95 %

Note (Relative humidity)

non-condensing

non-icing

Resistance to vibration to EN 60068-2-6

10 … 150 Hz, amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Protection class

III

Ambient conditions - Insulation values

Rated insulation voltage U

32 VDC

Rated impulse withstand voltage U

0.8 kV

Overvoltage category

III

Degree of pollution to IEC/EN 60664-1

3

Electrical data

Switching frequency, maximum

1 Hz

Electrical data - AS Interface

AS-i Operating voltage, minimum

26.5 VDC

AS-i Operating voltage AS-i maximum

31.6 VDC

Note (AS-i Operating voltage)

Protection against polarity reversal

AS-i Current consumption, maximum

100 mA

Electrical data - AS-Interface specification

AS-i Specification

Safety-Slave

AS-i Version

V 3.0

AS-i Profile

S-0.B.F.E

AS-i, IO-Code

0x0

AS-i, ID-Code

0xB

AS-i, ID-Code1

0xF

AS-i, ID-Code2

0xE

AS-i Input, Channel 1

Data bits DI 0 / DI 1 = dynamic code transmission

AS-i Input, Channel 2

Data bits DI 2 / DI 3 = dynamic code transmission

AS-i Outputs, DO 0

No Function

AS-i Outputs, DO 1

No Function

AS-i Outputs, DO 2

No Function

AS-i Outputs, DO 3

No Function

AS-i Parameter bits, P0

Safety guard and actuator detected

AS-i Parameter bits, P1

Static 0

AS-i Parameter bits, P3

Internal device error (FID)

Note (AS-i Parameter bits)

FID: periphery error

AS-i AS-i Parameter bits (A/B Slave), P2

Enabling inhibit (tamper protection time) active (FID)

AS-i Input module address

0

Note (AS-i Input module address)

Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Status indication

Note (LED switching conditions display)

Status and diagnostics: Transmitter + receiver

(2) LED red: Internal device error

(3) LED yellow: Device condition

Pin assignment

PIN 1

AS-Interface +

PIN 2

n.c.

PIN 3

AS-Interface -

PIN 4

n.c.

Scope of delivery

Scope of delivery

Actuators must be ordered separately.

Operating instructions and Declaration of conformity
  • AZ201-AS

    Download