101194954 - BNS 36 AS-R

Description: Product type description:BNS 36 (1)-AS-(2)(1)withoutConnecting cable (2 m)STGPre-wired cable with connector plug M12, straight, 4 poleSTWPre-wired cable with connector plug M12, angled, 4 pole(2)LDoor hinge on the left-hand sideRDoor hinge on the right-hand side
Description: Product type description:BNS 36 (1)-AS-(2)(1)withoutConnecting cable (2 m)STGPre-wired cable with connector plug M12, straight, 4 poleSTWPre-wired cable with connector plug M12, angled, 4 pole(2)LDoor hinge on the left-hand sideRDoor hinge on the right-hand side
Productfeatures
  • 2 m Pre-wired cable, 2-pole
  • Safety sensor
  • Thermoplastic enclosure
  • no mechanical wear
  • 88 mm x 25 mm x 13 mm
  • Integrated AS-Interface
  • Concealed mounting possible
  • Long life
  • Insensitive to transverse misalignment
  • Insensitive to soiling
  • AS-Interface LED and status display
Data
Ordering data

Product type description

BNS 36 AS-R

Article number (order number)

101194954

EAN (European Article Number)

4030661362250

eCl@ss number, version 9.0

27-27-24-02

eCl@ss number, version 11.0

27-27-24-02

ETIM number, version 7.0

EC002544

ETIM number, version 6.0

EC002544

Approvals - Standards

Certificates

TÜV

cULus

ASi-SaW

EAC

General data

Standards

EN 62026-2

EN ISO 13849-1

IEC 60947-5-3

IEC 61508

Working principle

Magnetic drive

Installation conditions (mechanical)

quasi-flush

Enclosure material

Glass-fibre, reinforced thermoplastic

Gross weight

95 g

Reaction time, maximum

100 ms

General data - Features

Coding

Yes

Integral system diagnostics, status

Yes

Mechanical data

Actuating element

Magnet

Door hinge

Right

Repeat accuracy

≤ 0.1 x S

Direction of motion

Head-on to the active surface

Mechanical data - Switching distances according EN IEC 60947-5-3

Note (Switching distance Sn)

Axial misalignment, a horizontal and vertical misalignment of the safety sensor and the actuator are tolerated. The possible misalignment depends on the distance of the active surfaces of the sensor and the actuator. The sensor remains active within the tolerance range.

Assured switching distance "ON" S

7 mm

Assured switching distance "OFF" S

17 mm

Mechanical data - Connection technique

Type of connection

Connecting cable, 2 pole

Length of cable

2 m

Wire cross-section

0.23 mm

Wire cross-section

23 AWG

Material of the Cable mantle

LSYY

Mechanical data - Dimensions

Length of sensor

13 mm

Height of sensor

25 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+60 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+70 °C

Resistance to vibration to EN 60068-2-6

10 … 55 Hz, amplitude 1 mm

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation values

Rated insulation voltage U

32 VDC

Rated impulse withstand voltage U

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data - AS Interface

AS-i Operating voltage, minimum

18 VDC

AS-i Operating voltage AS-i maximum

31.6 VDC

Note (AS-i Operating voltage)

Protection against polarity reversal

AS-i Current consumption, maximum

50 mA

Electrical data - AS-Interface specification

AS-i Specification

Safety-Slave

AS-i Version

V 2.1

AS-i Profile

S-0.B.F.E

AS-i, IO-Code

0x0

AS-i, ID-Code

0xB

AS-i, ID-Code1

0xF

AS-i, ID-Code2

0xE

AS-i Input, Channel 1

Data bits DI 0 / DI 1 = dynamic code transmission

AS-i Input, Channel 2

Data bits DI 2 / DI 3 = dynamic code transmission

AS-i Outputs, DO 0 … DO 3

No Function

AS-i Parameter bits, P0 ... P3

No function

Note (AS-i Parameter bits)

Set the parameter outputs to "1111" (0xF)

AS-i Input module address

0

Note (AS-i Input module address)

Preset to address 0, can be changed through AS-interface bus master or hand-held programming device

Status indication

Note (LED switching conditions display)

(1) LED green-red (AS-i Duo LED): Supply voltage / Communication error / Slave address = 0

(2) LED yellow: Enabling status

Pin assignment

PIN 1

Brown (AS interface +)

PIN 2

n.c.

PIN 3

Blue (AS interface −)

PIN 4

n.c.

Scope of delivery

Scope of delivery

Actuators must be ordered separately.

Operating instructions and Declaration of conformity
  • BNS 36 AS

    Download
TÜV certification
  • (791.0 kB, 01/12/2021)

    Download
UL Certificate
  • (413.1 kB, 08/01/2019)

    Download
SISTEMA-VDMA library
  • (109.5 kB, 11/11/2021)

    Download
  • TraceParts

    Download
  • SISTEMA

    Download