103011892 - AZM300Z-I2-ST-AS-T
- Brand: Schmersal
- Product Code: 103011892
- Thermoplastic enclosure
- Repeated individual coding with RFID technology
- Coding level "High" according to ISO 14119
- Suitable for hinged and sliding guards
- 3 different directions of actuation
- Guard locking monitored
- Power to unlock
- Emergency exit
- Magnet supply through the AS-Interface
- Hygienic design
- Protection class IP 69
- Solenoid interlock with integrated AS-i Safety Interface
- Universal repeatedly teachable or individual coding because of the RFID technology
- I-variants with coding level HIGH to ISO 14119
- 2 integrated snap-in stages
Data
Ordering data
Product type description | AZM300Z-I2-ST-AS-T |
Article number (order number) | 103011892 |
EAN (European Article Number) | 4030661480428 |
eCl@ss number, version 9.0 | 27-27-26-03 |
eCl@ss number, version 11.0 | 27-27-26-03 |
eCl@ss number, version 12.0 | 27-27-26-03 |
ETIM number, version 7.0 | EC002593 |
ETIM number, version 6.0 | EC002593 |
Approvals - Standards
Certificates | TÜV cULus ASi-SaW ECOLAB EAC FCC |
General data
Standards | EN 60947-5-1 EN 62026-2 EN ISO 13849-1 EN ISO 14119 IEC 61508 |
Coding | Individual coding, multiple teaching |
Coding level according to ISO 14119 | High |
Working principle | RFID |
Enclosure material | Glass-fibre, reinforced thermoplastic |
Gross weight | 644 g |
Time to readiness, maximum | 5,000 ms |
Reaction time, maximum | 120 ms |
Duration of risk, maximum | 200 ms |
General data - Features
Power to unlock | Yes |
Solenoid interlock monitored | Yes |
Latching | Yes |
Emergency exit | Yes |
Safety functions | Yes |
Integral system diagnostics, status | Yes |
Number of actuating directions | 3 |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Note (Mechanical life) | When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) |
Holding force | 1,150 N |
Latching force, adjustable, position 1 | 25 N |
Latching force, adjustable, position 2 | 50 N |
Mechanical data - Switching distances according EN IEC 60947-5-3
Switching distance | 2 mm |
Assured switching distance "ON" S | 1 mm |
Assured switching distance "OFF" S | 20 mm |
Mechanical data - Connection technique
Type of connection | Connector plug M12, 4-pole, (A-coding) |
Mechanical data - Dimensions
Length of sensor | 55 mm |
Width of sensor | 87.4 mm |
Height of sensor | 128.5 mm |
Ambient conditions
Degree of protection | IP67 IP69K IP66 |
Ambient temperature, minimum | +0 °C |
Ambient temperature, maximum | +60 °C |
Storage and transport temperature, minimum | -10 °C |
Storage and transport temperature, maximum | +90 °C |
Resistance to vibration to EN 60068-2-6 | 10 … 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection class | II |
Ambient conditions - Insulation values
Rated insulation voltage U | 32 VDC |
Rated impulse withstand voltage U | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data - AS Interface
AS-i Operating voltage, minimum | 26.5 VDC |
AS-i Operating voltage AS-i maximum | 31.6 VDC |
Note (AS-i Operating voltage) | Protection against polarity reversal |
AS-i Current consumption, maximum | 200 mA |
Electrical data - AS-Interface specification
AS-i Specification | Safety-Slave |
AS-i Version | V 3.0 |
AS-i Profile | S-7.B.F.E |
AS-i Input, Channel 1 | Data bits DI 0 / DI 1 = dynamic code transmission |
AS-i Input, Channel 2 | Data bits DI 2 / DI 3 = dynamic code transmission |
AS-i Outputs, DO 0 | Solenoid control |
AS-i Outputs, DO 1 | No Function |
AS-i Outputs, DO 2 | No Function |
AS-i Outputs, DO 3 | No Function |
AS-i Parameter bits, P0 | Safety guard closed and can be locked |
AS-i Parameter bits, P1 | Solenoid interlock locked |
AS-i Parameter bits, P2 | Auxiliary voltage in |
AS-i Parameter bits, P3 | Internal device error (FID) |
Note (AS-i Parameter bits) | Set the parameter outputs to "1111" (0xF) FID: periphery error |
AS-i Input module address | 0 |
Note (AS-i Input module address) | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Status indication
Note (LED switching conditions display) | (1) green/red LED (AS-i duo LED): Supply voltage/communication error/slave address = 0/periphery error detected/device error detected/manipulation protection active (2) LED yellow: Device condition (Enabling status) (3) LED red: Internal device error |
Pin assignment
PIN 1 | AS-Interface + |
PIN 2 | Aux - (P) |
PIN 3 | AS-Interface - |
PIN 4 | Aux + (P) |
Scope of delivery
Scope of delivery | Actuators must be ordered separately. |