Quick Links


Place here any module, widget, design or HTML. for example menu, categories

IIDM

103008178 - AZM300Z-I2-ST-SD2P-T

Description: Product type description:AZM300(1)(2)-ST(3)-(4)-(5)(1)ZGuard locking monitored >BActuator monitored(2)withoutStandard codingI1Individual codingI2Individual coding, multiple teaching(3)1P2P1 p-type diagnostic output and 2 p-type safety outputsSD2Pserial diagnostic output and 2 p-type safety outputs(4)withoutPower to unlockAPower to lock(5)withoutManual releaseNEmergency releaseTEmergency exitT 8Emergency exit, distance 8.5 mm
Description: Product type description:AZM300(1)(2)-ST(3)-(4)-(5)(1)ZGuard locking monitored >BActuator monitored(2)withoutStandard codingI1Individual codingI2Individual coding, multiple teaching(3)1P2P1 p-type diagnostic output and 2 p-type safety outputsSD2Pserial diagnostic output and 2 p-type safety outputs(4)withoutPower to unlockAPower to lock(5)withoutManual releaseNEmergency releaseTEmergency exitT 8Emergency exit, distance 8.5 mm
Productfeatures
  • Repeated individual coding with RFID technology
  • Coding level "High" according to ISO 14119
  • Connector M12, 8-pole
  • Power to unlock
  • Guard locking monitored
  • serial diagnostic output
  • Emergency exit
  • Hygienic design
  • Protection class IP 69
  • Suitable for mounting to profile systems
  • Thermoplastic enclosure
  • RFID-technology for needs-based protection against tampering
  • 3 different directions of actuation
  • Compact design
  • 3 LEDs to show operating conditions
  • Suitable for hinged and sliding guards
  • Series-wiring
  • Manual release
Data
Ordering data

Product type description

AZM300Z-I2-ST-SD2P-T

Article number (order number)

103008178

EAN (European Article Number)

4030661452197

eCl@ss number, version 9.0

27-27-26-03

eCl@ss number, version 11.0

27-27-26-03

eCl@ss number, version 12.0

27-27-26-03

ETIM number, version 7.0

EC002593

ETIM number, version 6.0

EC002593

Approvals - Standards

Certificates

TÜV

cULus

ECOLAB

EAC

FCC

IC

General data

Standards

EN ISO 13849-1

EN ISO 14119

IEC 60947-5-3

IEC 61508

Coding

Individual coding, multiple teaching

Coding level according to ISO 14119

High

Working principle

RFID

Frequency band RFID

125 kHz

Transmitter output, maximum

-6 dB/m

Enclosure material

Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Gross weight

660.1 g

Time to readiness, maximum

5,000 ms

Duration of risk, maximum

200 ms

Reaction time, switching off safety outputs via actuator, maximum

100 ms

Reaction time, switching off safety outputs via safety inputs, maximum

1.5 ms

General data - Features

Power to unlock

Yes

Solenoid interlock monitored

Yes

Serial diagnostics

Yes

Latching

Yes

Emergency exit

Yes

Short circuit detection

Yes

Cross-circuit detection

Yes

Series-wiring

Yes

Safety functions

Yes

Integral system diagnostics, status

Yes

Number of fail-safe digital outputs

2

Safety classification - Interlocking function

Performance Level, up to

e

Category

4

PFH value

5.20 x 10⁻¹⁰ /h

PFD value

4.50 x 10⁻⁵

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Note (Mechanical life)

When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)

Angular misalignment between solenoid interlock and actuator, maximum

2 °

Holding force in accordance with EN ISO 14119 F

1,150 N

Holding force, maximum F

1,500 N

Latching force, adjustable, position 1

25 N

Latching force, adjustable, position 2

50 N

Type of the fixing screws

2x M6

Tightening torque of the fixing screws, minimum

6 Nm

Tightening torque of the fixing screws, maximum

7 Nm

Mechanical data - Switching distances according EN IEC 60947-5-3

Switching distance

2 mm

Assured switching distance "ON" S

1 mm

Assured switching distance "OFF" S

20 mm

Mechanical data - Connection technique

Type of connection

Connector M12, 8-pole, A-coded

Length of sensor chain, maximum

200 m

Note (length of the sensor chain)

Cable length and cross-section change the voltage drop dependiing on the output current

Note (series-wiring)

Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD

Mechanical data - Dimensions

Length of sensor

146 mm

Width of sensor

87.5 mm

Height of sensor

55 mm

Ambient conditions

Degree of protection

IP67

IP69

IP66

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+60 °C

Storage and transport temperature, minimum

-10 °C

Storage and transport temperature, maximum

+90 °C

Relative humidity, maximum

93 %

Note (Relative humidity)

non-condensing

non-icing

Resistance to vibration to EN 60068-2-6

10 … 150 Hz, amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Protection class

III

Permissible installation altitude above sea level, maximum

2,000 m

Ambient conditions - Insulation values

Rated insulation voltage U

32 VDC

Rated impulse withstand voltage U

0.8 kV

Overvoltage category

III

Degree of pollution to IEC/EN 60664-1

3

Electrical data

Operating voltage, minimum

20.4 VDC

Operating voltage, maximum

26.4 VDC

Note (Power supply, general)

stabilised PELV power supply

No-load supply current, maximum I

100 mA

Current consumption with magnet ON, average

200 mA

Current consumption with magnet ON, peak

350 mA / 200 ms

Required rated short-circuit current to EN 60947-5-1

100 A

External wire and device fuse rating

2 A gG

Switching frequency, maximum

0.5 Hz

Electrical data - Magnet control

Designation, Magnet control

IN

Switching thresholds

-3 V … 5 V (Low)

15 V … 30 V (High)

Magnet switch-on time

100 %

Test pulse duration, maximum

5 ms

Test pulse interval, minimum

40 ms

Classification ZVEI CB24I, Sink

C0

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Safety digital inputs

Designation, Safety inputs

X1 und X2

Switching thresholds

−3 V … 5 V (Low)

15 V … 30 V (High)

Current consumption at 24V

5 mA

Test pulse duration, maximum

1 ms

Test pulse interval, minimum

100 ms

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Safety digital outputs

Designation, Safety outputs

Y1 and Y2

Design of switching elements

short-circuit proof, p-type

Voltage drop U

4 V

Leakage current I

0.5 mA

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.25 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.25 A

Test pulse duration, maximum

0.5 ms

Test pulse interval, typical

1000 ms

Classification ZVEI CB24I, Source

C2

Classification ZVEI CB24I, Sink

C1

C2

Electrical data - Diagnostic outputs

Designation, Diagnostic outputs

OUT

Design of switching elements

short-circuit proof, p-type

Voltage drop U

4 V

Voltage, Utilisation category DC-12

24 VDC

Current, Utilisation category DC-12

0.05 A

Voltage, Utilisation category DC-13

24 VDC

Current, Utilisation category DC-13

0.05 A

Electrical data - Serial diagnostic SD

Operation current

150 mA

Wiring capacitance

50 nF

Status indication

Note (LED switching conditions display)

Operating condition: LED green

Error / functional defect: LED red

Supply voltage UB: LED green

Pin assignment

PIN 1

A1 Supply voltage UB

PIN 2

X1 Safety input 1

PIN 3

A2 GND

PIN 4

Y1 Safety output 1

PIN 5

OUT serial diagnostic output

PIN 6

X2 Safety input 2

PIN 7

Y2 Safety output 2

PIN 8

IN serial diagnostic input

Scope of delivery

Scope of delivery

Actuators must be ordered separately.

Accessory

Recommendation (actuator)

AZ/AZM300-B1

Operating instructions and Declaration of conformity
  • AZM300

    Download
TÜV certification
  • AZM300 , AZ300 , AZM300-AS

    Download
ECOLAB certification
  • AZM300

    Download
UL Certificate
  • (413.5 kB, 08/01/2019)

    Download
UKCA certificate
  • (166.1 kB, 12/01/2021)

    Download
EC Declaration of conformity
  • AZM300

    Download
Brochure
  • AZM300

    Download
  • Electronic Safety Sensors and Solenoid Interlocks

    Download
SISTEMA-VDMA library
  • (131.9 kB, 12/09/2021)

    Download
  • TraceParts

    Download
  • ePLAN

    Download
  • CADENAS

    Download
  • SISTEMA

    Download