Description: GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Spectra? RMS circuit breakers are suitable for use on AC systems only.??Enclosure notes and/or limitation: For 3 phase, 4-wire Ground Fault, order Neutral Kit and Neutral Current Sensor Kit for GF applications (kits must be mounted in enclosure). ?Not suitable for 100% rated 1200 amp Spectra K frame breakers. ?Suitable for parallel 500 kcmil cable maximum. ?Enclosure does not include removable closing cap. ?Order raintight hub separately (requires field cut).??ACCESSORIES:?Neutral Kit (non-GF applications):TNIA800, TNIA1200, TNIA1200C?Neutral Kit(s) (for GF applications): TNIA800G, TNIA1200G?Neutral Current Sensor(s) (for GF applications): TSKG408, TSKG410, TSKG412?Raintight Hubs: TC200, TC250, TC300, TCCP
Description: GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Spectra? RMS circuit breakers are suitable for use on AC systems only.??Enclosure notes and/or limitation: For 3 phase, 4-wire Ground Fault, order Neutral Kit and Neutral Current Sensor Kit for GF applications (kits must be mounted in enclosure). ?Not suitable for 100% rated 1200 amp Spectra K frame breakers. ?Suitable for parallel 500 kcmil cable maximum. ?Enclosure does not include removable closing cap. ?Order raintight hub separately (requires field cut).??ACCESSORIES:?Neutral Kit (non-GF applications):TNIA800, TNIA1200, TNIA1200C?Neutral Kit(s) (for GF applications): TNIA800G, TNIA1200G?Neutral Current Sensor(s) (for GF applications): TSKG408, TSKG410, TSKG412?Raintight Hubs: TC200, TC250, TC300, TCCP
Specifications

Enclosure

NEMA Type 3R

Frame

K1200/SK1200

Mounting

Surface

Special Features

GE's circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment (except as noted). The short circuit rating of the enclosure/circuit breaker combination is equal to the short circuit rating of the installed circuit breaker. Spectra® RMS circuit breakers are suitable for use on AC systems only.

¶¶Enclosure notes and/or limitation: For 3 phase, 4-wire Ground Fault, order Neutral Kit and Neutral Current Sensor Kit for GF applications (kits must be mounted in enclosure). ¶Not suitable for 100% rated 1200 amp Spectra K frame breakers. ¶Suitable for parallel 500 kcmil cable maximum. ¶Enclosure does not include removable closing cap. ¶Order raintight hub separately (requires field cut).¶

¶ACCESSORIES:
¶Neutral Kit (non-GF applications):TNIA800, TNIA1200, TNIA1200C
¶Neutral Kit(s) (for GF applications): TNIA800G, TNIA1200G
¶Neutral Current Sensor(s) (for GF applications): TSKG408, TSKG410, TSKG412
¶Raintight Hubs: TC200, TC250, TC300, TCCP

Standard

CSA/UL

  • PDF

    Download